摘要
The results of a statistical study of the electric strength of a triggered vacuum switch (TVS) with a disk electrode system are presented. The electric strength of a switch was measured after switching currents with an amplitude of 3.5 kA at the commercial frequency. The dependence of the TVS breakdown voltage on the interelectrode distance is determined. It is shown that, when the interelectrode distance increases to 20-25 mm, the tested TVS prototype may serve as the basis for developing high-voltage TVSs intended for use in electric -power engineering as elements of switching and protective devices in networks of commercial frequency with a nominal voltage of 35 kV.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 50 条
  • [32] Study on a Modified Laser-Triggered Vacuum Switch
    Fan, Wenfang
    He, Zhenghao
    Wang, Ying
    Mao, Xiaopo
    Lin, Huazhong
    Tan, Fali
    [J]. 2015 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2015,
  • [33] Limit Rate of Current Rise in Triggered Vacuum Switch
    Alferov, D. F.
    Londer, Ya I.
    Ulyanov, K. N.
    [J]. 25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 258 - 261
  • [34] Research on the conduction process of laser triggered vacuum switch
    Shi, Rui
    Kong, Lingkai
    Li, Jie
    [J]. AIP ADVANCES, 2021, 11 (11)
  • [35] Laser Triggered Stability and Time Delay Characteristics of Laser Triggered Vacuum Switch
    Zhao Y.
    Liao M.
    Duan X.
    Liu Z.
    Ge G.
    [J]. Liao, Minfu (409254760@qq.com), 1600, China Machine Press (32): : 178 - 184
  • [36] Spectroscopic measurement of high current vacuum arc plasma in triggered vacuum switch
    Nam, SH
    Lee, BJ
    Park, SS
    Kim, SH
    Han, YJ
    Jung, JW
    Kim, JS
    Chu, JH
    Sung, GY
    [J]. PPPS-2001: PULSED POWER PLASMA SCIENCE 2001, VOLS I AND II, DIGEST OF TECHNICAL PAPERS, 2001, : 1790 - 1793
  • [37] On statistics of dielectric strength of triggered vacuum switches
    Alferov, DF
    Nevrovsky, VA
    Sidorov, VA
    [J]. ISDEIV: XXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, 2002, 20 : 194 - 197
  • [38] Modelling the initial plasma dynamics in a laser triggered vacuum switch
    Liu, Yuchen
    He, Zhenghao
    Xin, Yinan
    Zhang, Zhuoyu
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (07)
  • [39] Operational Characteristics of a Field-Breakdown Triggered Vacuum Switch
    Zhou Zhengyang
    Duan Xiongying
    Liao Minfu
    Dong Huajun
    Zou Jiyan
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (01) : 564 - 567
  • [40] Triggered vacuum switch-based fault current limiter
    Shi, Jing
    Zou, Jiyan
    He, Junjia
    [J]. IEEE Power Engineering Review, 2001, 21 (01): : 51 - 53