Analysis of a membrane reactor: Influence of membrane characteristics and operating conditions

被引:4
|
作者
Tanna, Nikunj P. [1 ]
Mayadevi, S.
机构
[1] Larsen & Toubro Ltd, Bombay 400072, Maharashtra, India
[2] Natl Chem Lab, CE & PD Div, Pune 411008, Maharashtra, India
关键词
membrane reactor; pervaporation membrane; esterification; performance; comparison;
D O I
10.2202/1542-6580.1354
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Modeling of an esterification reaction in a batch pervaporation membrane reactor (PVMR), and an analysis of the PVMR performance under different reaction conditions for different membrane characteristics are presented. Esterification of ethyl alcohol with acetic acid was considered as the model reaction. The PVMR performance for this reaction could be represented by a 2-step series model. The PVMR performance was similar to that of the batch reactor when both the reactors were in the kinetic regime. However, the performance of the PVMR was superior to that of the batch reactor when both were in the intermediate/equilibrium regime of the reaction. In these regions, the PVMR performance was influenced/limited by the membrane flux and selectivity. The analysis showed that the membrane flux affected the PVMR performance in the intermediate region and the membrane selectivity affected the performance in the equilibrium regime. Further, the limitations introduced by a low-flux membrane could be overcome by appropriate selection of the membrane area and that due to poor selectivity could be compensated to a certain extent by adjusting the feed ratio.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Influence of operating conditions on the refining of biogas to produce biomethane using membrane contactors
    Hidalgo-Barrio, Dolores
    Sanz-Bedate, Sergio
    Martin-Marroquin, Jesus
    Castro-Bustamante, Juan
    Antolin-Giraldo, Gregorio
    DYNA, 2020, 95 (04): : 388 - 393
  • [22] Second Law Analysis of a Membrane Humidifier under Various Operating Conditions
    Pollak, Markus
    Tegethoff, Wilhelm
    Koehler, Juergen
    Proceedings of ECOS 2022 - 35th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, 2022, : 283 - 294
  • [23] Analysis of stack operating conditions for a polymer electrolyte membrane fuel cell
    Saka, Kenan
    Orhan, Mehmet Fatih
    ENERGY, 2022, 258
  • [24] High-temperature ethane dehydrogenation in microporous zeolite membrane reactor: Effect of operating conditions
    Dangwal, Shailesh
    Liu, Ruochen
    Kim, Seok-Jhin
    CHEMICAL ENGINEERING JOURNAL, 2017, 328 : 862 - 872
  • [25] FUNDAMENTAL ANALYSIS OF A MEMBRANE REACTOR
    SHINDO, Y
    ITOH, N
    HARAYA, K
    WAKABAYASHI, K
    KAGAKU KOGAKU RONBUNSHU, 1989, 15 (06) : 1138 - 1143
  • [26] ANALYSIS OF A COCURRENT MEMBRANE REACTOR
    MOHAN, K
    GOVIND, R
    AICHE JOURNAL, 1986, 32 (12) : 2083 - 2086
  • [27] Influence of operating parameters and membrane fouling on nutrient transport by FO membrane
    Suleman, Saad Bin
    Hai, Faisal I.
    Mukhtar, Hamza
    Duong, Hung C.
    Ansari, Ashley J.
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 47
  • [28] Operating conditions of unconventional rib and membrane shells
    Krentowski, J
    Tribillo, R
    Shell Structures: Theory and Applications, 2005, : 583 - 587
  • [29] Synthesis of polyaluminum chloride with a membrane reactor: Process characteristics and membrane fouling
    Jia, Zhiqian
    He, Fei
    Liu, Zhongzhou
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2011, 23 (11) : 1794 - 1798