Electron beam dose calculation: Hybrid pencil beam model extended for small fields

被引:0
|
作者
Gou, CJ
Zeng, G
Luo, ZM [1 ]
机构
[1] Sichuan Univ, Educ Minist China, Key Lab Radiat Phys & Technol, Chengdu 610064, Peoples R China
[2] Sichuan Univ, Inst Nucl Sci & Technol, Chengdu 610064, Peoples R China
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The hybrid electron pencil beam model (HPBM) can usually be applied to middle or large fields and get good results, whereas it is sometimes not so successful to apply HPBM to small fields. In this note we report some results obtained by using an extended hybrid electron pencil beam model for small fields. Considering the condition of small fields, we redefine the central-axis depth dose for mono-energetic electrons in small fields and calculate the fitted spectrum of incident electron beam for these small fields. Through these improvements, we can make the extended hybrid electron pencil beam model applicable to small fields and obtain good results. And at the same time, the extended HPBM retains the calculation accuracy and efficiency for middle and large fields.
引用
收藏
页码:259 / 265
页数:7
相关论文
共 50 条
  • [31] A TWO-DIMENSIONAL PENCIL-BEAM ALGORITHM FOR CALCULATION OF ARC ELECTRON DOSE DISTRIBUTIONS
    HOGSTROM, KR
    KURUP, RG
    SHIU, AS
    STARKSCHALL, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (03): : 315 - 341
  • [33] DIFFERENTIAL PENCIL BEAM DOSE COMPUTATION MODEL FOR PHOTONS
    MOHAN, R
    CHUI, C
    LIDOFSKY, L
    MEDICAL PHYSICS, 1986, 13 (01) : 64 - 73
  • [34] THE OPTIMIZATION OF PENCIL BEAM WIDTHS FOR USE IN AN ELECTRON PENCIL BEAM ALGORITHM
    MCPARLAND, BJ
    CUNNINGHAM, JR
    WOO, MK
    MEDICAL PHYSICS, 1988, 15 (04) : 489 - 497
  • [35] Strip-beam electron pencil-beam redefinition dose calculations for modulated electron therapy
    Boyd, R
    Antolak, J
    Hogstrom, K
    MEDICAL PHYSICS, 2003, 30 (06) : 1447 - 1447
  • [36] A New Pencil Beam Model for Photon Dose Calculations
    Zhang, Pengcheng
    Shu, Huazhong
    Simon, Antoine
    Haigron, Pascal
    De Crevoisier, Renaud
    PROCEEDINGS OF THE 2013 6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2013), VOLS 1 AND 2, 2013, : 428 - 432
  • [37] PENCIL-BEAM REDEFINITION ALGORITHM FOR ELECTRON DOSE DISTRIBUTIONS
    SHIU, AS
    HOGSTROM, KR
    MEDICAL PHYSICS, 1991, 18 (01) : 7 - 18
  • [38] THE FERMI-EYGES PENCIL BEAM IN ELECTRON DOSE COMPUTATION
    SANDISON, GA
    HUDA, W
    MEDICAL PHYSICS, 1984, 11 (05) : 743 - 743
  • [39] Hybrid Dose Calculation with a Pencil Beam Algorithm and a GEANT4 Simulation for Hadron Therapy Application
    Aso, Tsukasa
    Kameoka, Satoru
    Nishio, Teiji
    Kimura, Akinori
    Murakami, Kouichi
    Sasaki, Takashi
    Yamashita, Tomohiro
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 730 - +
  • [40] Clinical Implementation of a GPU Accelerated Pencil Beam Dose Calculation Algorithm
    Chen, H.
    Xiao, Z.
    Du, D.
    Yang, D.
    Mutic, S.
    Li, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3823 - 3823