Discrepancies Between Transcutaneous and Serum Bilirubin Measurements

被引:81
|
作者
Taylor, James A. [1 ]
Burgos, Anthony E. [2 ]
Flaherman, Valerie [3 ]
Chung, Esther K. [4 ,5 ]
Simpson, Elizabeth A. [6 ]
Goyal, Neera K. [7 ,8 ]
Von Kohorn, Isabelle [9 ]
Dhepyasuwan, Nui [10 ]
机构
[1] Univ Washington, Dept Pediat, Seattle, WA 98195 USA
[2] Kaiser Permanente, Downey, CA USA
[3] Univ San Francisco, San Francisco, CA 94117 USA
[4] Thomas Jefferson Univ, Jefferson Med Coll, Dept Pediat, Philadelphia, PA 19107 USA
[5] DuPont Co Inc, Philadelphia, PA USA
[6] Childrens Mercy Hosp, Dept Pediat, Kansas City, MO 64108 USA
[7] Cincinnati Childrens Hosp Med Ctr, Dept Pediat, Cincinnati, OH 45229 USA
[8] Univ Cincinnati, Cincinnati, OH USA
[9] Holy Cross Hlth, Silver Spring, MD USA
[10] Acad Pediat Assoc, Mclean, VA USA
基金
美国国家卫生研究院;
关键词
BILICHECK; HYPERBILIRUBINEMIA;
D O I
10.1542/peds.2014-1919
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVE: To characterize discrepancies between transcutaneous bilirubin (TcB) measurements and total serum bilirubin (TSB) levels among newborns receiving care at multiple nursery sites across the United States. METHODS: Medical records were reviewed to obtain data on all TcB measurements collected during two 2-week periods on neonates admitted to participating newborn nurseries. Data on TSB levels obtained within 2 hours of a TcB measurement were also abstracted. TcB - TSB differences and correlations between the values were determined. Data on demographic information for individual newborns and TcB screening practices for each nursery were also collected. Multivariate regression analysis was used to identify characteristics independently associated with the TcB - TSB difference. RESULTS: Data on 8319 TcB measurements were collected at 27 nursery sites; 925 TSB levels were matched to a TcB value. The mean TcB - TSB difference was 0.84 +/- 1.78 mg/dL, and the correlation between paired measurements was 0.78. In the multivariate analysis, TcB - TSB differences were 0.67 mg/dL higher in African-American newborns than in neonates of other races (P < .001). The TcB - TSB difference also varied significantly based on brand of TcB meter used and hour of age of the infant. For 2.2% of paired measurements, the TcB measurement underestimated the TSB level by >= 3 mg/dL. CONCLUSIONS: During routine clinical care, TcB measurement provided a reasonable estimate of TSB levels in healthy newborns. Discrepancies between TcB and TSB levels were increased in African-American newborns and varied based on brand of meter used.
引用
收藏
页码:224 / 231
页数:8
相关论文
共 50 条
  • [21] Evaluation of the Relationship Between Transcutaneous Bilirubin Measurement and Total Serum Bilirubin in Neonatal Patients Followed for Jaundice
    Cat, Fatma Cetinkaya
    Cat, Abdulkadir
    Cicek, Tuba
    Gulec, Seda Geylani
    [J]. MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2021, 55 (02): : 262 - 267
  • [22] Comparison between Bilistick System and transcutaneous bilirubin in assessing total bilirubin serum concentration in jaundiced newborns
    Greco, C.
    Iskander, I. F.
    Akmal, D. M.
    El Houchi, S. Z.
    Khairy, D. A.
    Bedogni, G.
    Wennberg, R. P.
    Tiribelli, C.
    Zabetta, C. D. Coda
    [J]. JOURNAL OF PERINATOLOGY, 2017, 37 (09) : 1028 - 1031
  • [23] TRANSCUTANEOUS BILIRUBIN MEASUREMENTS IN THE WELL BABY NURSERY
    BIEHL, D
    ADAMKIN, DH
    [J]. CLINICAL RESEARCH, 1993, 41 (04): : A735 - A735
  • [24] Transcutaneous bilirubin measurements: useful, but also reproducible?
    Carlo Dani
    Christian V. Hulzebos
    Claudio Tiribelli
    [J]. Pediatric Research, 2021, 89 : 725 - 726
  • [25] Transcutaneous bilirubin measurements: useful, but also reproducible?
    Dani, Carlo
    Hulzebos, Christian V.
    Tiribelli, Claudio
    [J]. PEDIATRIC RESEARCH, 2021, 89 (04) : 725 - 726
  • [26] The acuuracy of Transcutaneous Bilirubin Measurements in Preterm Infants
    Alsafadi, Tariq Rushdi Mohieldeen
    Alsaedi, Saad Abdullah
    [J]. JOURNAL OF CLINICAL NEONATOLOGY, 2015, 4 (01) : 18 - 21
  • [27] EFFECT OF SKINFOLD THICKNESS ON TRANSCUTANEOUS BILIRUBIN MEASUREMENTS
    AMIT, Y
    JABBOUR, S
    ARAD, ID
    [J]. BIOLOGY OF THE NEONATE, 1993, 63 (04): : 209 - 214
  • [28] The accuracy of transcutaneous bilirubin measurements in neonates.
    Nanjundaswamy, S
    Petrova, A
    Mehta, R
    Hegyi, T
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2003, 51 : S420 - S420
  • [29] Utility of Decision Rules for Transcutaneous Bilirubin Measurements
    Taylor, James A.
    Burgos, Anthony E.
    Flaherman, Valerie
    Chung, Esther K.
    Simpson, Elizabeth A.
    Goyal, Neera K.
    Von Kohorn, Isabelle
    Dhepyasuwan, Niramol
    [J]. PEDIATRICS, 2016, 137 (05)
  • [30] Evaluation of the correlation between transcutaneous measurement and concentration of bilirubin in the blood serum of a newborn
    Morawiecka-Pietrzak, Malgorzata
    Morawska, Hanna
    Bursa, Janusz
    [J]. PEDIATRIA I MEDYCYNA RODZINNA-PAEDIATRICS AND FAMILY MEDICINE, 2016, 12 (03): : 296 - 302