Headspace-mass spectrometry determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers in soil samples using chemometrics

被引:37
|
作者
Esteve-Turrillas, F. A. [1 ]
Armenta, S. [1 ]
Garrigues, S. [1 ]
Pastor, A. [1 ]
de la Guardia, M. [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, Valencia 46100, Spain
关键词
benzene; toluene; ethylbenzene; xylene isomers; headspace-mass spectrometry; chemometric analysis;
D O I
10.1016/j.aca.2007.01.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and fast method has been developed for the determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers (BTEX) in soils. Samples were introduced in 10 mL standard glass vials of a headspace (HS) autosampler together with 150 mu L of 2,6,10,14-tetramethylpentadecane, heated at 90 degrees C for 10 min and introduced in the mass spectrometer by using a transfer line heated at 250 degrees C as interface. The volatile fraction of samples was directly introduced into the source of the mass spectrometer which was scanned from m/z 75 to 110. A partial least squares (PLS) multivariate calibration approach based on a classical 3 3 calibration model was build with mixtures of benzene, toluene and o-xylene in 2,6,10,14-tetramethylpentadecane for BTEX determination. Results obtained for BTEX analysis by HS-MS in different types of soil samples were comparables to those obtained by the reference HS-GC-MS procedure. So, the developed procedure allowed a fast identification and prediction of BTEX present in the samples without a prior chromatographic separation. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [21] HEADSPACE-MASS SPECTROMETRY WITH ALTERNATIVE CHROMATOGRAPHIC SEPARATION USING A COLUMN SWITCHING SYSTEM FOR THE SCREENING AND DETERMINATION OF BTEX AND STYRENE IN COMESTIBLE OIL
    Toledo, Carla
    Enriquez, Pedro
    Garrido, Mariano
    Fernandez-Band, Beatriz
    Richter, Pablo
    ANALYTICAL LETTERS, 2010, 43 (05) : 843 - 850
  • [22] Multivariate optimization of a solid phase microextraction-headspace procedure for the determination of benzene, toluene, ethylbenzene and xylenes in effluent samples from a waste treatment plant
    Gaujac, Alain
    Emidio, Elissandro Soares
    Navickiene, Sandro
    Costa Ferreira, Sergio Luis
    Dorea, Haroldo Silveira
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1203 (01) : 99 - 104
  • [23] Protocol for the analysis of high concentrations of benzene, toluene, ethylbenzene, and xylene isomers in water using automated solid-phase microextraction-GC-FID
    Thomas, SP
    Ranjan, R
    Webster, GRB
    Sarna, LP
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (05) : 1521 - 1526
  • [24] Determination of ageing time of spirits in oak barrels using a headspace-mass spectrometry (HS-MS) electronic nose system and multivariate calibration
    Martí, MP
    Pino, J
    Boqué, R
    Busto, O
    Guasch, J
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) : 440 - 443
  • [25] Optimization of Static Head-Space Gas Chromatography - Mass Spectrometry-Conditions for the Determination of Benzene, Toluene, Ethyl benzene, Xylene, and Styrene in Model Solutions
    Yilmazcan, Ozlem
    Tumay Ozer, Elif
    Izgi, Belgin
    Gucer, Seref
    EKOLOJI, 2013, 22 (89): : 76 - 83
  • [26] Liquid-liquid extraction/headspace/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene, (o-, m- and p-)xylene and styrene in olive oil using surfactant-coated carbon nanotubes as extractant
    Carrillo-Carrion, Carolina
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1171 (1-2) : 1 - 7
  • [27] A simplified Quick, Easy, Cheap, Effective, Rugged and Safe approach for the determination of trihalomethanes and benzene, toluene, ethylbenzene and xylenes in soil matrices by fast gas chromatography with mass spectrometry detection
    Garcia Pinto, Carmelo
    Herrero Martin, Sara
    Perez Pavon, Jose Luis
    Moreno Cordero, Bernardo
    ANALYTICA CHIMICA ACTA, 2011, 689 (01) : 129 - 136
  • [28] Simultaneous determination of polycyclic aromatic hydrocarbons and benzene, toluene, ethylbenzene and xylene in water samples using a new sampling strategy combining different extraction modes and temperatures in a single extraction solid-phase microextraction-gas chromatography-mass spectrometry procedure
    Bianchin, Joyce Nunes
    Nardini, Giuliana
    Merib, Josias
    Dias, Adriana Neves
    Martendal, Edmar
    Carasek, Eduardo
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1233 : 22 - 29
  • [29] Determination of benzene, toluene and xylene concentration in humid air using differential ion mobility spectrometry and partial least squares regression
    Maziejuk, M.
    Szczurek, A.
    Maciejewska, M.
    Pietrucha, T.
    Szyposzynska, M.
    TALANTA, 2016, 152 : 137 - 146
  • [30] Determination of the presence of benzene in vitamin drinks using headspace - solid phase microextraction and gas chromatography - mass spectrometry
    Kim, Jong-Hun
    Lee, Kyung-Min
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2007, 20 (03): : 237 - 245