Ultrasonograpy of VX-2 liver tumor in rabbit treated by high intensity focused ultrasound combined with microbubble contrast agent

被引:0
|
作者
Ji Xiaojuan [1 ,2 ]
Wang Zhibiao [2 ]
Zou Jianzhong [2 ]
Chen Wenzhi [2 ]
Bai Jin [2 ]
机构
[1] Chongqing Univ Med Sci, Childrens Hosp, Dept Cardiol, Chongqing 400014, Peoples R China
[2] Chongqing Univ Med Sci, Inst Ultrasound Engn Med, Chongqing 400016, Peoples R China
关键词
rabbit/animal model; liver tumor; microbubble contrast agent; high intensity focused ultrasound; sonogram;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: To assess the value of sonographic appearance and to investigate the sonographic character of VX-2 liver tumor in rabbit treated by high intensity focused ultrasound (HIFU) combined with microbubble contrast agent. Methods: Forty-five rabbits bearing VX-2 tumors were randomly averagely assigned into three groups. In group A irradiation was sustained until the target region became hyperechoic. In group B therapy was stopped as soon as hyperecho occurred, and in group C irradiation time was prolonged to ensure the occurrence of coagulation necrosis. Results: Exposure duration for tumors treated purely with HIFU was the longest, whilst the use of microbubble contrast agent combined with HIFU shortened the exposure duration significantly. The gross examination and ultrasonogram coagulation necrosis area measurements correlated strongly (r=0.986,P < 0.05) in the microbubble-enhanced HIFU group. Conclusion: It was feasible to enhance HIFU therapy with microbubble contrast agent. The characteristic change in the ultrasound images made it possible to assess the enhanced HIFU therapeutic efficacy in order to adjust the treatment program.
引用
收藏
页码:390 / +
页数:2
相关论文
共 50 条
  • [1] Effect of microbubble contrast agent during high intensity focused ultrasound ablation on rabbit liver in vivo
    Chung, Dong Jin
    Cho, Se Hyun
    Lee, Jae Mun
    Hahn, Seong-Tae
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E519 - E523
  • [2] Effect of Healthy Tissue Ablation Surrounding VX2 Rabbit Liver Tumors by High-Intensity Focused Ultrasound Combined With an Ultrasound Contrast Agent
    Fan, Zhiyong
    Luo, Wen
    Song, Zhenshun
    Zheng, Wei
    Hu, Haitian
    Du, Lixue
    Zhou, Xiaodong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (06) : 863 - 871
  • [3] Non-thermal ablation of rabbit liver VX2 tumor by pulsed high intensity focused ultrasound with ultrasound contrast agent: Pathological characteristics
    Zhou, Cheng-Wen
    Li, Fa-Qi
    Qin, Yan
    Liu, Chun-Mei
    Zheng, Xiao-Lin
    Wang, Zhi-Biao
    WORLD JOURNAL OF GASTROENTEROLOGY, 2008, 14 (43) : 6743 - 6747
  • [4] Non-thermal ablation of rabbit liver VX2 tumor by pulsed high intensity focused ultrasound with ultrasound contrast agent:Pathological characteristics
    Cheng-Wen Zhou Xiao-Lin Zheng Bioengineering College
    State Key Laboratory of Ultrasound Engineering in Medicine Cofounded by Chongqing and MOST
    World Journal of Gastroenterology, 2008, 14 (43) : 6743 - 6747
  • [5] Evaluation of contrast enhancement in rabbit liver with VX-2 tumor using contrast agent YM454
    Maruyama, Hitoshi
    Matsutani, Shoichi
    Saisho, Hiromitsu
    Kamiyama, Naohisa
    Yuki, Hidenobu
    Miyata, Keiji
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [6] The use of a microbubble agent to enhance rabbit liver destruction using high intensity focused ultrasound
    Yu, TH
    Xiong, SH
    Mason, TJ
    Wang, ZB
    ULTRASONICS SONOCHEMISTRY, 2006, 13 (02) : 143 - 149
  • [7] Combination of high-intensity focused ultrasound with nanoscale ultrasound contrast agent in treatment of rabbit breast VX2 tumors: a pilot study
    Wang, Dong
    Li, Lu
    Min, Jiayan
    Guo, Yu
    Guo, Haiying
    Gao, Jing
    Yang, Ke
    Zou, Jianzhong
    CLINICAL IMAGING, 2012, 36 (06) : 717 - 723
  • [8] Microbubble contrast agent SonoVue combined with oxytocin improves the efficiency of high-intensity focused ultrasound ablation for adenomyosis
    Yao, Ruihong
    Zhao, Wei
    Gao, Bulang
    Hu, Jihong
    Wang, Tao
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 1601 - 1608
  • [9] EXTRACORPOREAL HIGH-INTENSITY FOCUSED ULTRASOUND FOR VX2 LIVER-TUMORS IN THE RABBIT
    PRAT, F
    CENTARTI, M
    SIBILLE, A
    ELFADIL, FA
    HENRY, L
    CHAPELON, JY
    CATHIGNOL, D
    HEPATOLOGY, 1995, 21 (03) : 832 - 836
  • [10] Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue
    Yukio Kaneko
    Toshiyuki Maruyama
    Kenji Takegami
    Toshiaki Watanabe
    Hiroshi Mitsui
    Kazuyuki Hanajiri
    Hirokazu Nagawa
    Yoichiro Matsumoto
    European Radiology, 2005, 15 : 1415 - 1420