A novel method for measuring subcutaneous adipose tissue using ultrasound in children - interobserver consistency

被引:0
|
作者
Chirita-Emandi, Adela [1 ]
Papa, Maria Camelia [2 ]
Abrudan, Liliana [2 ]
Dobrescu, Mihaela Amelia [3 ]
Puiu, Maria [1 ,2 ]
Velea, Iulian Puiu [4 ]
Paul, Corina [4 ]
机构
[1] Victor Babes Univ Med & Pharm, Dept Genet, Timisoara, Romania
[2] Louis Turcanu Emergency Hosp Children, Dept Genet, Timisoara, Romania
[3] Univ Med & Pharm Craiova, Dept Genet, 2 Petru Rares St, Craiova 200349, Romania
[4] Victor Babes Univ Med & Pharm, Dept Pediat, Timisoara, Romania
来源
ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY | 2017年 / 58卷 / 01期
关键词
ultrasound; uncompressed subcutaneous adipose tissue thickness; children; reliability; BODY-MASS INDEX; X-RAY ABSORPTIOMETRY; SKINFOLD THICKNESSES; RISK-FACTORS; FAT; VARIABILITY; RELIABILITY; OVERWEIGHT; ADOLESCENTS; PREVALENCE;
D O I
暂无
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Currently, sufficiently accurate field methods for body composition assessment in children are missing. The ultrasound method for assessing adipose tissue thickness has been used extensively in sport medicine. However, there are no studies looking at the reliability of this method in non-athletic children. This paper aims to determine the inter-observer reliability in measuring the uncompressed subcutaneous adipose tissue thickness using ultrasound, in children. Subjects, Materials and Methods: Forty healthy children (20 males, 20 females), median age 11.85 years (5.3 to 18.1 years) were evaluated. Median body mass index standard deviation score (BMI SDS) was -0.13 (-3.9 to 4). Three observers used a Hosand BX 2000 Ultrasonic Adipometer to measure uncompressed subcutaneous adipose tissue thickness at three sites: triceps, subscapular, supraspinale. A single experienced observer used the three sites to also measure the compressed adipose thickness using a skinfold caliper. Results: Individual observer deviations from the mean value of the three observers in adipometer measurement had a standard deviation of 1.74 mm, 92.8% were less than 3 mm. Analysis separated by individual anatomical sites showed high reliability values for triceps: linear regression R-2=0.84, p=0.000; intraclass correlation coefficient (ICC)=0.92 and standard error of measurement (SEM)=0.63. The values at supraspinale site were R-2=0.82, p=0.000, ICC=0.89 and SEM=1.17, while for subscapular the values were lower: R-2=0.79, p=0.000, ICC=0.78 and SEM=1.02. The body fat percentage (BF%) calculated using skinfold measurements was highly correlated with the BF% calculated by the adipometer (R=0.92, R-2=0.83, p=0.000). The Pearson's correlation between BMI SDS and BF% calculated from skinfold was R=0.52, R-2=0.28, p=0.001, while for the adipometer it was R=0.53, R-2=0.27, p=0.000. Conclusions: This novel ultrasound measurement technique can be used with good accuracy and reliability to measure uncompressed subcutaneous adipose tissue thickness in children, sustaining its application for research and clinical purposes, however larger studies are needed.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 50 条
  • [21] High-Intensity Focused Ultrasound for the Reduction of Subcutaneous Adipose Tissue Using Multiple Treatment Techniques
    Robinson, Deanne M.
    Kaminer, Michael S.
    Baumann, Leslie
    Burns, A. Jay
    Brauer, Jeremy A.
    Jewell, Mark
    Lupin, Mark
    Narurkar, Vic A.
    Struck, Steven K.
    Hledik, Jennifer
    Dover, Jeffrey S.
    DERMATOLOGIC SURGERY, 2014, 40 (06) : 641 - 651
  • [22] Technical considerations for accurate measurement of subcutaneous adipose tissue thickness using B-mode ultrasound
    Toomey, C.
    McCreesh, K.
    Leahy, S.
    Jakeman, P.
    ULTRASOUND, 2011, 19 (02) : 91 - 96
  • [23] NEW METHOD OF MEASURING PRESSURE OF SKIN AND SUBCUTANEOUS TISSUE
    PAROT, S
    BOURLIER.
    GERONTOLOGIA, 1967, 13 (02): : 95 - 95
  • [24] Total and segmental subcutaneous adipose tissue volume measured by ultrasound in men and women
    Yoshitomi, A
    Midorikawa, T
    Kojima, K
    Abe, T
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S74 - S74
  • [25] Measurement of subcutaneous adipose tissue development in children by the optical device LIPOMETER
    Möller, R
    Horejsi, R
    Sudi, K
    Berg, A
    Reibnegger, G
    Tafeit, E
    DIAGNOSTIC OPTICAL SPECTROSCOPY IN BIOMEDICINE, 2001, 4432 : 268 - 273
  • [26] Subcutaneous Adipose Tissue Segmentation in Whole-Body MRI of Children
    Fouquier, Geoffroy
    Anquez, Jeremie
    Bloch, Isabelle
    Falip, Celine
    Adamsbaum, Catherine
    PROGRESS IN PATTERN RECOGNITION, IMAGE ANALYSIS, COMPUTER VISION, AND APPLICATIONS, 2011, 7042 : 97 - +
  • [27] EVALUATION OF HIGH-INTENSITY FOCUSED ULTRASOUND FOR THE REDUCTION OF SUBCUTANEOUS ADIPOSE TISSUE USING MULTIPLE TREATMENT TECHNIQUES
    Robinson, Deanne Mraz
    Kaminer, Michael S.
    Baumann, Leslie
    Burns, A. Jay
    Geronemus, Roy G.
    Jewell, Mark
    Lupin, Mark
    Narurkar, Vic A.
    Struck, Steven K.
    Elford, Erica
    Dover, Jeffrey S.
    LASERS IN SURGERY AND MEDICINE, 2013, 45 : 21 - 21
  • [28] Continuous oxygen monitoring in subcutaneous adipose tissue using microdialysis
    Bizzarri, Alessandro
    Koehler, Hans
    Cajlakovic, Merima
    Pasic, Alen
    Schaupp, Lukas
    Klimant, Ingo
    Ribitsch, Volker
    ANALYTICA CHIMICA ACTA, 2006, 573 : 48 - 56
  • [29] A new method for measuring soft tissue thicknesses of the face using ultrasound.
    Smith, S. L.
    Throckmorton, G. S.
    Buschang, P. H.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2004, : 184 - 185
  • [30] Results on reduction of subcutaneous adipose tissue using a novel body contouring system based on microwave technology
    Bonan, Paolo
    Coli, Federica
    DERMATOLOGIE, 2023, 74 (10): : 765 - 771