A novel method for measuring subcutaneous adipose tissue using ultrasound in children - interobserver consistency

被引:0
|
作者
Chirita-Emandi, Adela [1 ]
Papa, Maria Camelia [2 ]
Abrudan, Liliana [2 ]
Dobrescu, Mihaela Amelia [3 ]
Puiu, Maria [1 ,2 ]
Velea, Iulian Puiu [4 ]
Paul, Corina [4 ]
机构
[1] Victor Babes Univ Med & Pharm, Dept Genet, Timisoara, Romania
[2] Louis Turcanu Emergency Hosp Children, Dept Genet, Timisoara, Romania
[3] Univ Med & Pharm Craiova, Dept Genet, 2 Petru Rares St, Craiova 200349, Romania
[4] Victor Babes Univ Med & Pharm, Dept Pediat, Timisoara, Romania
来源
ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY | 2017年 / 58卷 / 01期
关键词
ultrasound; uncompressed subcutaneous adipose tissue thickness; children; reliability; BODY-MASS INDEX; X-RAY ABSORPTIOMETRY; SKINFOLD THICKNESSES; RISK-FACTORS; FAT; VARIABILITY; RELIABILITY; OVERWEIGHT; ADOLESCENTS; PREVALENCE;
D O I
暂无
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Currently, sufficiently accurate field methods for body composition assessment in children are missing. The ultrasound method for assessing adipose tissue thickness has been used extensively in sport medicine. However, there are no studies looking at the reliability of this method in non-athletic children. This paper aims to determine the inter-observer reliability in measuring the uncompressed subcutaneous adipose tissue thickness using ultrasound, in children. Subjects, Materials and Methods: Forty healthy children (20 males, 20 females), median age 11.85 years (5.3 to 18.1 years) were evaluated. Median body mass index standard deviation score (BMI SDS) was -0.13 (-3.9 to 4). Three observers used a Hosand BX 2000 Ultrasonic Adipometer to measure uncompressed subcutaneous adipose tissue thickness at three sites: triceps, subscapular, supraspinale. A single experienced observer used the three sites to also measure the compressed adipose thickness using a skinfold caliper. Results: Individual observer deviations from the mean value of the three observers in adipometer measurement had a standard deviation of 1.74 mm, 92.8% were less than 3 mm. Analysis separated by individual anatomical sites showed high reliability values for triceps: linear regression R-2=0.84, p=0.000; intraclass correlation coefficient (ICC)=0.92 and standard error of measurement (SEM)=0.63. The values at supraspinale site were R-2=0.82, p=0.000, ICC=0.89 and SEM=1.17, while for subscapular the values were lower: R-2=0.79, p=0.000, ICC=0.78 and SEM=1.02. The body fat percentage (BF%) calculated using skinfold measurements was highly correlated with the BF% calculated by the adipometer (R=0.92, R-2=0.83, p=0.000). The Pearson's correlation between BMI SDS and BF% calculated from skinfold was R=0.52, R-2=0.28, p=0.001, while for the adipometer it was R=0.53, R-2=0.27, p=0.000. Conclusions: This novel ultrasound measurement technique can be used with good accuracy and reliability to measure uncompressed subcutaneous adipose tissue thickness in children, sustaining its application for research and clinical purposes, however larger studies are needed.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 50 条
  • [1] Measuring Subcutaneous Adipose Tissue Using Ultrasound in Children
    Chirita-Emandi, Adela
    Puiu, Maria
    HORMONE RESEARCH IN PAEDIATRICS, 2016, 86 : 114 - 114
  • [2] Measurement of Subcutaneous Adipose Tissue in Pre-School Children using Ultrasound
    Kelso, Anne
    Vogel, Katharina
    Steinacker, Juergen
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 486 - 486
  • [3] MEASUREMENT OF SUBCUTANEOUS ADIPOSE-TISSUE USING ULTRASOUND IMAGES
    RAMIREZ, ME
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1992, 89 (03) : 347 - 357
  • [4] VALIDITY OF ULTRASONIC TECHNIQUE AS A METHOD OF MEASURING SUBCUTANEOUS ADIPOSE-TISSUE
    HAYMES, EM
    LUNDEGREN, HM
    LOOMIS, JL
    BUSKIRK, ER
    ANNALS OF HUMAN BIOLOGY, 1976, 3 (03) : 245 - 251
  • [5] Body composition in sport: interobserver reliability of a novel ultrasound measure of subcutaneous fat tissue
    Mueller, Wolfram
    Horn, Martin
    Fuerhapter-Rieger, Alfred
    Kainz, Philipp
    Kroepfl, Julia M.
    Ackland, Timothy R.
    Lohman, Timothy G.
    Maughan, Ronald J.
    Meyer, Nanna L.
    Sundgot-Borgen, Jorunn
    Stewart, Arthur D.
    Ahammer, Helmut
    BRITISH JOURNAL OF SPORTS MEDICINE, 2013, 47 (16) : 1036 - 1043
  • [6] MEASUREMENT OF SUBCUTANEOUS ADIPOSE-TISSUE USING A NEEDLE METHOD
    DOBOS, G
    KLUTHE, R
    AKTUELLE ERNAHRUNGSMEDIZIN, 1987, 12 (04): : 136 - 138
  • [7] A novel biopsy method to increase yield of subcutaneous abdominal adipose tissue
    T L Alderete
    F R Sattler
    X Sheng
    J Tucci
    S D Mittelman
    E G Grant
    M I Goran
    International Journal of Obesity, 2015, 39 : 183 - 186
  • [8] A novel biopsy method to increase yield of subcutaneous abdominal adipose tissue
    Alderete, T. L.
    Sattler, F. R.
    Sheng, X.
    Tucci, J.
    Mittelman, S. D.
    Grant, E. G.
    Goran, M. I.
    INTERNATIONAL JOURNAL OF OBESITY, 2015, 39 (01) : 183 - 186
  • [9] Assessment of subcutaneous adipose tissue using ultrasound in highly trained junior rowers
    Kelso, Anne
    Trajer, Emese
    Machus, Katja
    Treff, Gunnar
    Mueller, Wolfram
    Steinacker, Juergen M.
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2017, 17 (05) : 576 - 585
  • [10] Ultrasound measurements of subcutaneous adipose tissue in infants are reproducible
    Flygare, A
    Valentin, L
    Karlsland-Åkeson, P
    Flodmark, CE
    Ivarsson, SA
    Axelsson, I
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1999, 28 (05): : 492 - 494