Surface characterization of retrieved NiTi orthodontic archwires

被引:100
|
作者
Eliades, T
Eliades, G
Athanasiou, AE
Bradley, TG
机构
[1] Univ Manchester, Sch Dent, Dent Biomat Sci Unit, Manchester M13 9PL, Lancs, England
[2] Res Ctr Biomat, Athens, Greece
[3] Aristotelian Univ Salonika, Dept Orthodont, Salonika, Greece
[4] Marquette Univ, Div Orthodont, Milwaukee, WI 53233 USA
关键词
D O I
10.1093/ejo/22.3.317
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The structure and morphological condition of retrieved NiTi orthodontic archwires was evaluated and any possible alterations in the surface composition of the alloy following 1-6 months in vivo were characterized. NiTi wires (GAC, German Orthodontics, ORMCO) of various cross-sections were collected through a retrieval protocol and were subjected to multi-technique characterization. Optical microscopy revealed islands of amorphous precipitants and accumulated microcrystalline particles. Micro MIR-FTIR investigation of the retrieved samples demonstrated the presence of a proteinaceous biofilm, the organic constituents of which were mainly amide, alcohol, and carbonate. Scanning electron microscope and X-ray microanalysis showed that the elemental species precipitated on the material surface were Na, K, Cl, Ca, and P, forming NaCl, KCl, and Ca-P precipitates. Increased intra-oral exposure was consistently associated with the presence of a mature film, while evidence of alloy delamination, pitting, and crevice corrosion, as well as a notable reduction in the alloy grain size was observed. Intra-oral exposure of NiTi wires alters the topography and structure of the alloy surface through surface attack in the form of pitting or crevice corrosion or formation of integuments. Further in vivo research is required to resolve the implications of the described ageing pattern in the corrosion resistance of the alloy, the potential for nickel leaching, as well as bracket-archwire friction variants.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 50 条
  • [11] Characterisation of NiTi orthodontic archwires characteristic functional properties
    Rudolf, Rebeka
    Fercec, Janko
    Lazic, Vojkan
    Veselinovic, Valentina
    Tomic, Sergej
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING 2017 (CMBEBIH 2017), 2017, 62 : 323 - 332
  • [12] Thermal Programming of Commercially Available Orthodontic NiTi Archwires
    Wichelhaus, Andrea
    Mehnert, Amelie
    Stocker, Thomas
    Baumert, Uwe
    Mertmann, Matthias
    Sabbagh, Hisham
    Seidel, Corinna L.
    MATERIALS, 2023, 16 (10)
  • [13] The mechanical behavior of as received and retrieved nickel titanium orthodontic archwires
    Lombardo, Luca
    Toni, Giorgia
    Mazzanti, Valentina
    Mollica, Francesco
    Spedicato, Giorgio Alfredo
    Siciliani, Giuseppe
    PROGRESS IN ORTHODONTICS, 2019, 20 (1)
  • [14] The mechanical behavior of as received and retrieved nickel titanium orthodontic archwires
    Luca Lombardo
    Giorgia Toni
    Valentina Mazzanti
    Francesco Mollica
    Giorgio Alfredo Spedicato
    Giuseppe Siciliani
    Progress in Orthodontics, 20
  • [15] Laser welding of NiTi orthodontic archwires for selective force application
    P. Sevilla
    F. Martorell
    C. Libenson
    J. A. Planell
    F. J. Gil
    Journal of Materials Science: Materials in Medicine, 2008, 19 : 525 - 529
  • [16] Improvement of the friction behaviour of NiTi orthodontic archwires by nitrogen diffusion
    Gil, FJ
    Solano, E
    Campos, A
    Boccio, F
    Sáez, I
    Alfonso, MV
    Planell, JA
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1998, 8 (5-6) : 335 - 342
  • [17] Laser welding of NiTi orthodontic archwires for selective force application
    Sevilla, P.
    Martorell, F.
    Libenson, C.
    Planell, J. A.
    Gil, F. J.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (02) : 525 - 529
  • [18] A prospective cohort study assessing the appearance of retrieved aesthetic orthodontic archwires
    Collier, S.
    Pandis, N.
    Johal, A.
    Qureshi, U.
    Sharma, P. K.
    Fleming, P. S.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2018, 21 (01) : 27 - 32
  • [19] Variation in surface topography of different NiTi orthodontic archwires in various commercial fluoride-containing environments
    Huang, Her-Hsiung
    DENTAL MATERIALS, 2007, 23 (01) : 24 - 33
  • [20] Effect of Fluoride Content of Mouthwashes on Superelastic Properties of NiTi Orthodontic Archwires
    Pastor, Francisco
    Carlos Rodriguez, Juan
    Maria Barrera, Jose
    Delgado Garcia-Menocal, Jose Angel
    Brizuela, Aritza
    Puigdollers, Andreu
    Espinar, Eduardo
    Gil, Javier
    MATERIALS, 2022, 15 (19)