Analysis-by-synthesis voicing cut-off determination in harmonic coding

被引:0
|
作者
Jia, WH [1 ]
Chan, WY [1 ]
机构
[1] Brooktrout Technol, Los Gatos, CA 95032 USA
关键词
D O I
10.1109/SCFT.2000.878397
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In low bit-rate harmonic speech coding, voicing information is often specified by a cut-off frequency of the spectrum. Many approaches of cut-off estimation depend on spectral matching, where a fixed prototype spectrum is used to model voiced harmonics. However, voiced harmonics do not always show a regular shape. One of the causes is harmonic interference. We propose an analysis-by-synthesis voicing cut-off determination scheme that takes into account harmonic interactions in spectral-matching. The proposed scheme has been embedded in a 2.4 kb/s harmonic coder. Subjective listening tests show that the scheme performs well and is robust against noise.
引用
收藏
页码:65 / 67
页数:3
相关论文
共 50 条
  • [41] Wideband electric field probe lower cut-off frequency determination
    Sarolic, Antonio
    Modlic, Borivoj
    Poljak, Dragan
    ICECom 2005: 18th International Conference on Applied Electromagnetics and Communications, Conference Proceedings, 2005, : 129 - 132
  • [43] DETERMINATION OF TRUE DISTRIBUTION PARAMETERS FROM CUT-OFF DISTRIBUTION DATA
    TERENTEVA, LM
    BUDTOV, VP
    VYSOKOMOLEKULYARNYE SOEDINENIYA SERIYA A, 1978, 20 (03): : 702 - 708
  • [44] Determination of an Appropriate Cut-Off Value for Ferritin in the Diagnosis of Hemophagocytic Lymphohistiocytosis
    Lehmberg, Kai
    McClain, Kenneth L.
    Janka, Gritta E.
    Allen, Carl E.
    PEDIATRIC BLOOD & CANCER, 2014, 61 (11) : 2101 - 2103
  • [45] A convenient method for the determination of molecular weight cut-off of ultrafiltration membranes
    Li, Cunyu
    Ma, Yun
    Li, Hongyang
    Peng, Guoping
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2017, 25 (01) : 62 - 67
  • [46] Alternative Determination of the Intrinsic Cut-Off Frequency Applied to a Degraded MOSFET
    Cuchillo-Sanchez, Hector
    Zarate-Rincon, Fabian
    Torres-Torres, Reydezel
    IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2016, 26 (09) : 693 - 695
  • [47] Determination of Appropriate Urine Volume Cut-Off Values for Cytology Adequacy
    Qi, Yan
    Monaco, Sara
    Xing, Juan
    Pantanowitz, Liron
    MODERN PATHOLOGY, 2018, 31 : 168 - 169
  • [48] ELISA validation and determination of cut-off level for chloramphenicol residues in honey
    Biernacki, Bogumil
    BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2015, 59 (03) : 353 - 356
  • [49] Newborn screening for mucopolysaccharidoses: Determination of sensitivity, specificity and cut-off score
    Gan, Qi
    Campbell, Mary
    Thomas, Anthony
    Tomatsu, Shunji
    Suzuki, Yasuyuki
    Yamaguchi, Seiji
    Montana, Adriana M.
    MOLECULAR GENETICS AND METABOLISM, 2015, 114 (02) : S44 - S44
  • [50] Determination of the UV cut-off from the observed value of the Universe acceleration
    Cherkas, S. L.
    Kalashnikov, V. L.
    JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS, 2007, (01):