Cementing acetabular sockets into metal-backed acetabular components and antiprotrusio cages: A technical tip

被引:1
|
作者
Ezzet, Kace A. [1 ]
机构
[1] Scripps Clin, Div Orthopaed Surg, La Jolla, CA 92037 USA
来源
JOURNAL OF ARTHROPLASTY | 2007年 / 22卷 / 04期
关键词
cemented acetabular components; antiprotrusio cages; revision hip arthroplasty; cemented liners; cemented screw heads;
D O I
10.1016/j.arth.2006.12.053
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cementing a polyethylene socket or acetabular liner into a well-fixed metal-backed acetabular shell has become a useful procedure in selected complex primary and revision hip arthroplasties. Polyethylene sockets are frequently cemented into antiprotrusio cages as well. Frequently, these metallic devices are fixed to host bone with acetabular screws. Unfortunately, when polyethylene sockets are cemented into such devices, the cement fills the recess within the screw head and makes subsequent screw removal extremely difficult should the device need to be removed or revised. The author describes a technique of filling the screw heads with bone wax and gel foam before cementation. This keeps the recess within the screw head relatively patent and allows easier removal of the screw in the future should it become necessary.
引用
收藏
页码:609 / 611
页数:3
相关论文
共 50 条
  • [41] Failure of an uncemented non-porous metal-backed prosthesis with augmentation using impacted allograft for acetabular revision - Reply
    Scott, G
    Jeffery, M
    Freeman, M
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (07): : 1089 - 1089
  • [42] Howse II cemented titanium metal-backed acetabular cups - Poor 10-year results in 107 hips
    Mohan, R
    Grigoris, P
    Johnstone, F
    Hamblen, DL
    ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (04): : 397 - 403
  • [43] Trabecular metal versus non-trabecular metal acetabular components for acetabular revision surgery
    Lu, Jiajia
    Lu, Nan
    Fu, Qiang
    Shi, Xiaojian
    INTERNATIONAL JOURNAL OF SURGERY, 2023, 109 (11) : 3677 - 3678
  • [44] All-polyethylene Tibial Components are Equal to Metal-backed Components
    Nouta, Klaas Auke
    Verra, Wiebe C.
    Pijls, Bart G.
    Schoones, Jan W.
    Nelissen, Rob G. H. H.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (12) : 3549 - 3559
  • [45] Massive acetabular bone loss: Limits of trabecular metal cages
    Villanueva-Martinez, Manuel
    Rios-Luna, Antonio
    Diaz-Maurino, Juan
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (01) : 78 - 81
  • [46] Salvage of Failed Acetabular Cages by Nonbuttressed Trabecular Metal Cups
    Kosashvili, Yona
    Safir, Oleg
    Backstein, David
    Lakstein, Dror
    Gross, Allan E.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) : 466 - 471
  • [47] Removing Cemented Dual Mobility Liners From Acetabular Components: A Technical Tip for a Challenging Surgical Problem
    Wilson, Jacob M.
    Mika, Aleksander
    Martin, Ryan
    ARTHROPLASTY TODAY, 2023, 23
  • [48] Acetabular metal backed fatigue due to severe wear before revision
    Griza, S.
    Ce, A. N.
    Silva, E. P.
    Bertoni, F.
    Reguly, A.
    Strohaecker, T. R.
    ENGINEERING FAILURE ANALYSIS, 2009, 16 (07) : 2036 - 2042
  • [49] Technical factors for success with metal ring acetabular reconstruction
    Udomkiat, P
    Dorr, LD
    Won, YY
    Longjohn, D
    Wan, ZN
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 961 - 969
  • [50] The use of the Explant® device in metal backed Exeter™ acetabular component revision
    Kent, B. P.
    Matthews, E. C.
    Blake, S. M.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2015, 97 (05) : 403 - 403