Inferior vena cava segmentation with parameter propagation and graph cut

被引:1
|
作者
Yan, Zixu [1 ]
Chen, Feng [2 ]
Wu, Fa [1 ]
Kong, Dexing [1 ]
机构
[1] Zhejiang Univ, Sch Math Sci, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Sch Med, Affiliated Hosp 1, Dept Radiol, Hangzhou 310003, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Inferior vena cava; Segmentation; Regional appearances; Shape prior; Graph cut; ENERGY MINIMIZATION; VESSEL SEGMENTATION; SCALE-SPACE; LIVER; ALGORITHMS; VASCULATURE; ARTERIES; VOLUME; NOISE; TREE;
D O I
10.1007/s11548-017-1582-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The inferior vena cava (IVC) is one of the vital veins inside the human body. Accurate segmentation of the IVC from contrast-enhanced CT images is of great importance. This extraction not only helps the physician understand its quantitative features such as blood flow and volume, but also it is helpful during the hepatic preoperative planning. However, manual delineation of the IVC is time-consuming and poorly reproducible. In this paper, we propose a novel method to segment the IVC with minimal user interaction. The proposed method performs the segmentation block by block between user-specified beginning and end masks. At each stage, the proposed method builds the segmentation model based on information from image regional appearances, image boundaries, and a prior shape. The intensity range and the prior shape for this segmentation model are estimated based on the segmentation result from the last block, or from user- specified beginning mask if at first stage. Then, the proposed method minimizes the energy function and generates the segmentation result for current block using graph cut. Finally, a backward tracking step from the end of the IVC is performed if necessary. We have tested our method on 20 clinical datasets and compared our method to three other vessel extraction approaches. The evaluation was performed using three quantitative metrics: the Dice coefficient (Dice), the mean symmetric distance (MSD), and the Hausdorff distance (MaxD). The proposed method has achieved a Dice of , an MSD of mm, and a MaxD of mm, respectively, in our experiments. The proposed approach can achieve a sound performance with a relatively low computational cost and a minimal user interaction. The proposed algorithm has high potential to be applied for the clinical applications in the future.
引用
收藏
页码:1481 / 1499
页数:19
相关论文
共 50 条
  • [21] Leiomyosarcoma of the Inferior Vena Cava
    Monteagudo Cortecero, Juana
    Guirau Rubio, Maria Dolores
    Paya Roma, Artemio
    RADIOGRAPHICS, 2015, 35 (02) : 616 - 620
  • [22] Leiomyosarcoma of the inferior vena cava
    Sadri, Ben Abid
    Amine, Attaoui Mohamed
    Zeineb, Mzoughi
    Nizar, Miloudi
    Lassad, Gharbi
    Khalfallah, Mohamed Tahar
    CLINICS AND PRACTICE, 2013, 3 (01) : 18 - 19
  • [23] Inferior vena cava aneurysm
    Moustafa, Sherif E.
    Mookadam, Martina
    Khandheria, Bijoy K.
    Mookadam, Farouk
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (12) : 1418.e5 - 1418.e7
  • [24] OCCLUSION OF INFERIOR VENA CAVA
    CASWELL, HT
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1956, 160 (15): : 1374 - 1374
  • [25] THE VALVE OF THE INFERIOR VENA CAVA
    HICKIE, JB
    BRITISH HEART JOURNAL, 1956, 18 (03): : 320 - 326
  • [26] UNUSUAL INFERIOR VENA CAVA
    WEATHERSBY, HT
    ANATOMICAL RECORD, 1960, 136 (02): : 351 - 351
  • [27] Inferior vena cava duplication
    Chiarugi, Massimo
    Fregoli, Lorenzo
    Iacconi, Pietro
    UPDATES IN SURGERY, 2015, 67 (03) : 325 - 327
  • [28] Ligation of the inferior vena cava
    Whittenberger, JL
    Huggins, C
    ARCHIVES OF SURGERY, 1940, 41 (06) : 1334 - 1343
  • [29] Double Inferior Vena Cava
    Tirilomis, Theodor
    HEART SURGERY FORUM, 2012, 15 (03): : 172 - 173
  • [30] Leiomyosarcoma of the inferior vena cava
    Schwarzbach, M
    Willeke, F
    Hoffmann, V
    Mechtersheimer, G
    Otto, G
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1997, 122 (14) : 439 - 444