Current Status of MHI's CO2 Recovery Technology and Optimization of CO2 Recovery Plant with a PC Fired Power Plant

被引:27
|
作者
Kishimoto, Shinya [1 ]
Hirata, Takuya [2 ]
Iijima, Masaki [1 ]
Ohishi, Tsuyoshi [1 ]
Higaki, Kazuo [3 ]
Mitchell, Ronald [1 ]
机构
[1] Mitsubishi Heavy Ind Co Ltd, Plant & Transportat Syst Engn & Construct Ctr, Nishi Ku, 3-3-1 Minatomirai, Yokohama, Kanagawa 2208401, Japan
[2] Mitsubishi Heavy Ind Co Ltd, Hiroshima R&D Ctr, Nishi Ku, Hiroshima, Japan
[3] Mitsubishi Heavy Ind Co Ltd, Power Syst Project Engn Dept, Nagasaki, Japan
来源
关键词
CO2; Recovery; PC fired; Power Plant; MHI;
D O I
10.1016/j.egypro.2009.01.144
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
It is the opinion of the authors that CO2 Capture and Storage (CCS) technology can significantly contribute as an effective countermeasure against climate change, allowing us to continue the utilization of fossil fuels for primary energy production. However for this technology to be widely deployed on a commercial basis there are three key issues that need to be addressed; (1) Reduction in energy consumption, (2) Efficient integration with other environmental control equipment of a PC power plant and (3) Reduction in the decrease of net electrical output. MHI has delivered multiple commercial CO2 recovery plants in the chemical and fertilizer industries, which recover CO2 from natural gas fired flue gas, with four commercial plants in operation and another four under construction, all utilizing the proprietary KM-CDR process. In order to gain experience with CO2 recovery from a coal fired flue gas stream, Mitsubishi Heavy Industries (MHI), together with a subsidy from RITE and cooperation from J-POWER, constructed a 10 metric ton per day (T/D) CO2 recovery demonstration plant at the 2 x 500MW Matsushima power station in southern Japan. This demonstration plant has subsequently achieved more than 4,000 hours of successful test operation during 2006 2007 with a further 1,000 hours during 2008, and testing continues today. The demonstration testing confirmed that the KM-CDR process is applicable to coal fired flue gas streams. Future research priorities include the improved integration of the CO2 recovery process with the flue gas pre-treatment components and the additional optimization of removal and separation methods for coal based impurities accumulating in the absorbent. An issue of concern for power plant operators is the reduction of the net electrical output due to the demands of CO2 recovery process. MHI has made significant improvements in this area and in the efficiency of absorbents. However, it is necessary to further reduce the adverse impact on the net electrical output of the power plant via astute integration of the energy transferred between the power plant and the Post Combustion CO2 Capture (PCC) plant. MHI is investigating the following concepts; (1) Utilizing the waste heat of the PCC plant for the power plant, (2) Utilizing heat recovery from the flue gas for the CO2 recovery process and (3) Utilizing the compression heat of the CO2 compressor for the CO2 recovery process. (c) 2008 Elsevier Ltd. All rights reserved
引用
收藏
页码:1091 / 1098
页数:8
相关论文
共 50 条
  • [1] CO2 recovery pilot plant
    Jang, KR
    Kim, JH
    Shim, JG
    Ahn, YM
    Eum, HM
    [J]. CARBON DIOXIDE UTILIZATION FOR GLOBAL SUSTAINABILITY, 2004, 153 : 397 - 404
  • [2] CO2 recovery in a power plant with chemical looping combustion
    Ishida, M
    Jin, H
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1997, 38 : S187 - S192
  • [3] PULVERIZED COAL COMBUSTION IN O-2 CO2 MIXTURES ON A POWER-PLANT FOR CO2 RECOVERY
    NAKAYAMA, S
    NOGUCHI, Y
    KIGA, T
    MIYAMAE, S
    MAEDA, U
    KAWAI, M
    TANAKA, T
    KOYATA, K
    MAKINO, H
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (5-8) : 379 - 386
  • [4] Trial design for a CO2 recovery power plant by burning pulverized coal in O-2/CO2
    Okawa, M
    Kimura, N
    Kiga, T
    Takano, S
    Arai, K
    Kato, M
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1997, 38 : S123 - S127
  • [5] CO2 RECOVERY IMPROVES COGEN PLANT ECONOMICS
    RUSHING, SA
    [J]. POWER ENGINEERING, 1994, 98 (04) : 46 - 47
  • [6] Comparison and Analysis of CO2 Capture Technology of Coal-fired Power Plant
    Wang, Chao
    Chen, ShenQian
    Ren, JianXing
    [J]. 3RD INTERNATIONAL CONFERENCE ON MECHANICS, DYNAMIC SYSTEMS AND MATERIAL ENGINEERING (MDSME 2015), 2015, : 113 - 116
  • [7] IHI S Amine -Based Co2 Capture Technology For Coal Fired Power Plant.
    Nakamura, Shiko
    Yamanaka, Yasuro
    Matsuyama, Toshiya
    Okuno, Shinya
    Sato, Hiroshi
    [J]. GHGT-11, 2013, 37 : 1897 - 1903
  • [8] Current Status of MHI CO2 Capture Plant technology, Large Scale Demonstration project and Road Map to Commercialization for Coal Fired Flue Gas Application
    Endo, Takahiko
    Kajiya, Yoshinori
    Nagayasu, Hiromitsu
    Iijima, Masaki
    Ohishi, Tsuyoshi
    Tanaka, Hiroshi
    Mitchell, Ronald
    [J]. 10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1513 - 1519
  • [9] Simulation of an Amine-based CO2 Recovery Plant
    Pourjazaieri, S.
    Zoveidavianpoor, M.
    Shadizadeh, S. R.
    [J]. PETROLEUM SCIENCE AND TECHNOLOGY, 2011, 29 (01) : 39 - 47
  • [10] Design of CO2 absorption plant for recovery of CO2 from flue gases of gas turbine
    Mofarahi, Masoud
    Khojasteh, Yaser
    Khaledi, Hiwa
    Farahnak, Arsalan
    [J]. ENERGY, 2008, 33 (08) : 1311 - 1319