摘要
A reliable and highly sensitive electrochemical sensor was first developed for analysis of non-electroactive melamine (Mel) based on its conversion to an electroactive complex by coordination of copper salt to Mel. This provides a simple and easy approach to the detection of Mel in milk products.
引用
收藏
页码:2259 / 2261
页数:3
相关论文
共 50 条
  • [31] Lable-Free Fluorescencet Detection of Melamine Based on Its Inhibition on Synthesis of Copper Nanoclusters
    Ou Li-Juan
    Luo Jian-Xin
    Sun Ai-Ming
    Chen Si-Yu
    Wang Ling-Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (08) : 1233 - 1237
  • [32] ELECTROCHEMICAL AND COMPUTATIONAL STUDY OF COPPER (II) ALKYLPYRAZOLONE BASED ENAMINE COMPLEX
    Moreno, Y.
    Belmar, J.
    Brovelli, F.
    Buljan, A.
    Pena, O.
    Moreno, L.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2008, 53 (04): : 1689 - 1693
  • [33] Electrochemical aptamer sensor for thrombin based on cerium complex signal probe
    Wang Cun
    Zou Xiao-Chuan
    Huang Yuan-Bo
    Hu Jing
    Deng Ming-Chuan
    Feng Xia
    CHINESE JOURNAL OF INORGANIC CHEMISTRY, 2023, 39 (10) : 1931 - 1940
  • [34] Imprinted sol-gel electrochemical sensor for melamine direct recognition and detection
    Xu, Guilin
    Zhang, Hongli
    Zhong, Min
    Zhang, Tingting
    Lu, Xiaojing
    Kan, Xianwen
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 713 : 112 - 118
  • [35] Electrochemical stripping chemiluminescent sensor based on copper nanoclusters for detection of carcinoembryonic antigen
    Shi, Bing-Jiao
    Shang, Lei
    Zhang, Wei
    Jia, Li-Ping
    Ma, Rong-Na
    Xue, Qing-Wang
    Wang, Huai-Sheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 344
  • [36] Determination of copper(II) in the dairy product by an electrochemical sensor based on click chemistry
    Qiu, Suyan
    Xie, Lidan
    Gao, Sen
    Liu, Qida
    Lin, Zhenyu
    Qiu, Bin
    Chen, Guonan
    ANALYTICA CHIMICA ACTA, 2011, 707 (01) : 57 - 61
  • [37] An electrochemical sensor based on reduced graphene oxide and copper sulfide hollow nanospheres
    Wang, Suiping
    Han, Zheng
    Li, Yafei
    Peng, Renfu
    Feng, Bo
    RSC ADVANCES, 2015, 5 (130): : 107318 - 107325
  • [38] Ion Imprinted Polymer Based Electrochemical Sensor for Environmental Monitoring of Copper(II)
    Abu-Dalo, Muna A.
    Salam, Abubakar A.
    Nassory, Nabil S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (08): : 6780 - 6793
  • [39] Crystal structure of new melamine bridged polymeric complex of copper(II)
    G. M. Mamoor
    O. Şahin
    Islam Ullah Khan
    O. Ejaz
    Journal of Structural Chemistry, 2011, 52 : 1115 - 1119
  • [40] Crystal structure of new melamine bridged polymeric complex of copper(II)
    Mamoor, G. M.
    Sahin, O.
    Khan, Islam Ullah
    Ejaz
    Buyukgungor, O.
    JOURNAL OF STRUCTURAL CHEMISTRY, 2011, 52 (06) : 1115 - 1119