Quantification of key folate forms in serum using stable-isotope dilution ultra performance liquid chromatography-tandem mass spectrometry

被引:51
|
作者
Kirsch, Susanne H. [1 ]
Knapp, Jean-Pierre [1 ]
Herrmann, Wolfgang [1 ]
Obeid, Rima [1 ]
机构
[1] Saarland Univ Hosp, Dept Clin Chem & Lab Med, D-66421 Homburg, Germany
关键词
Folate; 5-Methyltetrahydrofolate; Folic acid; Homocysteine; Tandem mass spectrometry; NEURAL-TUBE DEFECTS; METHYLENETETRAHYDROFOLATE REDUCTASE; FOLIC-ACID; THERMAL-DESTRUCTION; SAMPLE PREPARATION; VASCULAR-DISEASE; COMMON MUTATION; RISK-FACTOR; RADIOASSAY; FOLACIN;
D O I
10.1016/j.jchromb.2009.11.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Folates act as essential coenzymes in many biological pathways. Alteration in folate form distribution might have biological significance, especially in relation to certain genetic polymorphisms. We developed a stable-isotope dilution ultra performance liquid chromatography-mass spectrometry (UPLC-MS/MS) method for quantification of the folate forms 5-methyltetrahydrofolate (5-methylTHF), 5-formylTHF, 5,10-methenylTHF, THF, and folic acid in serum. After extraction using an ion exchange and mixed mode solid-phase, samples were separated and detected using an UPLC-MS/MS system. The quantification limits were between 0.17 nmol/L (5-formylTHF) and 1.79 nmol/L (THF), and the assay was linear up to 100 nmol/L (5-methylTHF) and 10 nmol/L (5-formylTHF, 5,10-methenylTHF, THF, and folic acid). The intraassay CVs for 5-methylTHF and 5-formylTHF were 2.0% and 7.2%, respectively. Mean recoveries were between 82.3% for THF and 110.8% for 5,10-methenylTHF. Concentrations of total folate measured by the new method showed a strong correlation with those measured by an immunologic assay (r = 0.939; p, < 0.001). The mean total folate from 32 apparently healthy subjects was 18.09 nmol/L, of which 87.23% was 5-methylTHF. Concentrations of homocysteine showed a better correlation to the total folate measured by the new method compared to that obtained by an immunologic assay. We also confirmed that MTHFR polymorphism has a significant effect on folate distribution in this small population of non-supplemented subjects. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
  • [31] Isotope-dilution liquid chromatography-tandem mass spectrometry for quantification of human retinol binding protein 4 in serum
    Tian, Xue
    Yang, Sheng
    Tang, Qu
    Ji, Huoyan
    Shen, Lei
    Wang, Jianxin
    ANALYTICAL BIOCHEMISTRY, 2022, 645
  • [32] Quantification of midostaurin in plasma and serum by stable isotope dilution liquid chromatography-tandem mass spectrometry: Application to a cohort of patients with acute myeloid leukemia
    Wiesen, Martin H. J.
    Stemler, Jannik
    Fietz, Cornelia
    Joisten, Carolin
    Cornely, Oliver A.
    Verougstraete, Nick
    Streichert, Thomas
    Mueller, Carsten
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2024, 112 (06) : 879 - 888
  • [33] Comparison of four different immunoassays and a rapid isotope-dilution liquid chromatography-tandem mass spectrometry assay for serum folate
    Jin, Lizi
    Lu, Youli
    Yi, Xilian
    Zhang, Meiwei
    Zhang, Jiangtao
    Zhou, Weiyan
    Zeng, Jie
    Zhang, Tianjiao
    Zhang, Chuanbao
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (09) : 1393 - 1402
  • [34] Facile gas chromatography-tandem mass spectrometry stable isotope dilution method for the quantification of sesquiterpenes in grape
    Duhamel, Nina
    Slaghenaufi, Davide
    Pilkington, Lisa I.
    Johnstone, Mandy Herbst
    Larcher, Roberto
    Barker, David
    Fedrizzi, Bruno
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1537 : 91 - 98
  • [35] Isotope-dilution liquid chromatography-tandem mass spectrometry for sensitive quantification of human insulin in serum using derivatization-technique
    Sakaguchi, Yohei
    Kinumi, Tomoya
    Takatsu, Akiko
    ANALYTICAL BIOCHEMISTRY, 2017, 537 : 26 - 32
  • [36] Simultaneous quantification of S-adenosyl methionine and S-adenosyl homocysteine in human plasma by stable-isotope dilution ultra performance liquid chromatography tandem mass spectrometry
    Kirsch, Susanne H.
    Knapp, Jean-Pierre
    Geisel, Juergen
    Herrmann, Wolfgang
    Obeid, Rima
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (30): : 3865 - 3870
  • [37] Development and validation of a stable-isotope dilution liquid chromatography-tandem mass spectrometry method for the determination of bisphenols in ready-made meals
    Regueiro, Jorge
    Wenzl, Thomas
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1414 : 110 - 121
  • [38] Total serum pentosidine quantification using liquid chromatography-tandem mass spectrometry
    Blencowe, Lindsie A.
    Bozovic, Andrea
    Wonge, Evelyn
    Kulasingam, Vathany
    Cheung, Angela M.
    BONE REPORTS, 2024, 20
  • [39] Development and validation of stable-isotope dilution liquid chromatography-tandem mass spectrometric method for determination of salivary progesterone
    Higashi, Tatsuya
    Ito, Koichi
    Narushima, Misato
    Sugiura, Takahiro
    Inagaki, Shinsuke
    Min, Jun Zhe
    Toyo'oka, Toshimasa
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (11) : 1175 - 1180
  • [40] Quantification of levetiracetam in plasma of neonates by ultra performance liquid chromatography-tandem mass spectrometry
    Blonk, Maren I.
    van der Nagel, Bart C.
    Smit, Liesbeth S.
    Mathot, Ron A. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 675 - 681