Hemodynamic study of overlapping bare-metal stents intervention to aortic aneurysm

被引:27
|
作者
Zhang, Peng [1 ]
Sun, Anqiang [1 ]
Zhan, Fan [1 ]
Luan, Jingyuan [2 ]
Deng, Xiaoyan [1 ]
机构
[1] Beihang Univ, Sch Biol Sci & Med Engn, Minist Educ, Key Lab Biomech & Mechanobiol, Beijing 100191, Peoples R China
[2] Peking Univ, Dept Intervent Radiol & Vasc Surg, Hosp 3, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Thoracic aortic aneurysm; Overlapping bare-metal stents; Hemodynamics; Numerical simulation; ENDOVASCULAR REPAIR; MULTILAYER STENT; THORACOABDOMINAL ANEURYSMS; INTERACTION SIMULATION; ARTERY ANEURYSM; FLOW PATTERNS; ENDOLEAKS; PERFORMANCE; OUTCOMES; STRESS;
D O I
10.1016/j.jbiomech.2014.08.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To investigate the hemodynamic performance of overlapping bare-metal stents intervention treatment to thoracic aortic aneurysms (TAA), three simplified TAA models, representing, no stent, with a single stent and 2 overlapped stents deployed in the aneurismal sac, were studied and compared in terms of flow velocity, wall shear stress (WSS) and pressure distributions by means of computational fluid dynamics. The results showed that overlapping stents intervention induced a flow field of slow velocity near the aneurismal wall. Single stent deployment in the sac reduced the jet-like flow formed prior to the proximal neck of the aneurysm, which impinged on the internal wall of the aneurysm. This jet-like flow vanished completely in the overlapping double stents case. Overlapping stents intervention led to an evident decrease in WSS; meanwhile, the pressure acting on the wall of the aneurysm was reduced slightly and presented more uniform distribution. The results therefore indicated that overlapping stents intervention may effectively isolate the thoracic aortic aneurysm, protecting it from rupture. In conclusion, overlapping bare-metal stents may serve a purpose similar to that of the multilayer aneurysm repair system (MARS) manufactured by Cardiatis SA (Isnes, Belgium). (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3524 / 3530
页数:7
相关论文
共 50 条
  • [41] Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention
    Baschet, Louise
    Bourguignon, Sandrine
    Marque, Sebastien
    Durand-Zaleski, Isabelle
    Teiger, Emmanuel
    Wilquin, Fanny
    Levesque, Karine
    OPEN HEART, 2016, 3 (02):
  • [42] Comparison in survival outcomes between drug-eluting stents and bare-metal stents
    Omerovic, E.
    EUROPEAN HEART JOURNAL, 2012, 33 : 554 - 554
  • [43] Drug-eluting stents versus bare-metal stents for acute coronary syndrome
    Feinberg, Joshua
    Nielsen, Emil Eik
    Greenhalgh, Janette
    Hounsome, Juliet
    Sethi, Naqash J.
    Safi, Sanam
    Gluud, Christian
    Jakobsen, Janus C.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (08):
  • [44] Outcomes in the Era of Bare-Metal Stents vs the Era of Drug-Eluting Stents
    Beri, Abhimanyu
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (01): : 33 - 33
  • [45] Outcomes of Diabetics Receiving Bare-Metal Stents Versus Drug-Eluting Stents
    Ramanath, Vijay S.
    Brown, Jeremiah R.
    Malenka, David J.
    DeVries, James T.
    Sidhu, Mandeep S.
    Robb, John F.
    Jayne, John E.
    Hettleman, Bruce D.
    Friedman, Bruce J.
    Niles, Nathaniel W., II
    Kaplan, Aaron V.
    Thompson, Craig A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (04) : 473 - 481
  • [46] Outcomes of covered stents versus bare-metal stents for subclavian artery occlusive disease
    Wei, Libing
    Gao, Xixiang
    Tong, Zhu
    Cui, Shijun
    Guo, Lianrui
    Gu, Yongquan
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [47] Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents
    Kastrati, Adnan
    Mehilli, Julinda
    Pache, Juergen
    Kaiser, Christoph
    Valgimigli, Marco
    Kelbaek, Henning
    Menichelli, Maurizio
    Sabate, Manel
    Suttorp, Maarten J.
    Baumgart, Dietrich
    Seyfarth, Melchior
    Pfisterer, Matthias E.
    Schoemig, Albert
    NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10): : 1030 - 1039
  • [48] Cost-effectiveness of sirolimus-eluting stents compared with bare-metal stents
    Caroline Barranco
    Nature Clinical Practice Cardiovascular Medicine, 2005, 2 (9): : 439 - 439
  • [49] Comparing the safety and efficacy of sirolimus-eluting stents and common bare-metal stents
    Nazeri, I
    Nazeri, A
    Shokoufi-Moghiman, S
    Hashemy, K
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (8A): : 46A - 46A
  • [50] Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease
    Bonaa, K. H.
    Mannsverk, J.
    Wiseth, R.
    Aaberge, L.
    Myreng, Y.
    Nygard, O.
    Nilsen, D. W.
    Klow, N. -E.
    Uchto, M.
    Trovik, T.
    Bendz, B.
    Stavnes, S.
    Bjornerheim, R.
    Larsen, A. -I.
    Slette, M.
    Steigen, T.
    Jakobsen, O. J.
    Bleie, O.
    Fossum, E.
    Hanssen, T. A.
    Dahl-Eriksen, O.
    Njolstad, I.
    Rasmussen, K.
    Wilsgaard, T.
    Nordrehaug, J. E.
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (13): : 1242 - 1252