3D biofilm visualization and quantification on granular bioanodes with magnetic resonance imaging

被引:20
|
作者
Caizan-Juanarena, Leire [1 ]
Krug, Julia R. [2 ,3 ,4 ]
Vergeldt, Frank J. [3 ,4 ]
Kleijn, J. Mieke [5 ]
Velders, Aldrik H. [2 ,4 ]
Van As, Henk [3 ,4 ]
Ter Heijne, Annemiek [1 ]
机构
[1] Wageningen Univ & Res, Environm Technol, Bornse Weilanden 9, NL-6708 WG Wageningen, Netherlands
[2] Wageningen Univ & Res, Lab BioNanoTechnol, Bornse Weilanden 9, NL-6708 WG Wageningen, Netherlands
[3] Wageningen Univ & Res, Lab Biophys, Stippeneng 4, NL-6708 WE Wageningen, Netherlands
[4] Wageningen Univ & Res, MAGNEt Resonance Res Facil, Stippeneng 4, NL-6708 WE Wageningen, Netherlands
[5] Wageningen Univ & Res, Phys Chem & Soft Matter, Stippeneng 4, NL-6708 WE Wageningen, Netherlands
关键词
Microbial fuel cells; Activated carbon granules; Porous electrodes; Magnetic resonance imaging; Biofilm distribution; Biofilm volume; MICROBIAL FUEL-CELL; GEOBACTER-SULFURREDUCENS; ELECTRICITY PRODUCTION; WASTE-WATER; RESOURCE RECOVERY; DOUBLE-LAYER; TRANSPORT; PERFORMANCE; DIFFUSION; MICROSCOPY;
D O I
10.1016/j.watres.2019.115059
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of microbial fuel cells (MFCs) for wastewater treatment fits in a circular economy context, as they can produce electricity by the removal of organic matter in the wastewater. Activated carbon (AC) granules are an attractive electrode material for bioanodes in MFCs, as they are cheap and provide electroactive bacteria with a large surface area for attachment. The characterization of biofilm growth on AC granules, however, is challenging due to their high roughness and three-dimensional structure. In this research, we show that 3D magnetic resonance imaging (MRI) can be used to visualize biofilm distribution and determine its volume on irregular-shaped single AC granules in a non-destructive way, while being combined with electrochemical and biomass analyses. Ten AC granules with electroactive biofilm (i.e. granular bioanodes) were collected at different growth stages (3 to 21 days after microbial inoculation) from a multi-anode MFC and T-1-weighted 3D-MRI experiments were performed for three-dimensional biofilm visualization. With time, a more homogeneous biofilm distribution and an increased biofilm thickness could be observed in the 3D-MRI images. Biofilm volumes varied from 0.4 mu L (day 4) to 2 mu L (day 21) and were linearly correlated (R-2 = 0.9) to the total produced electric charge and total nitrogen content of the granular bioanodes, with values of 66.4 C mu L-1 and 17 mu g N mu L-1 , respectively. In future, in situ MRI measurements could be used to monitor biofilm growth and distribution on AC granules. (C) 2019 The Authors. Published by Elsevier Ltd.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Quantification using 3D imaging
    Herman, GT
    CRITICAL REVIEWS IN DIAGNOSTIC IMAGING, 2001, 42 (01) : 29 - 57
  • [22] 3D visualization and quantification of bowing marble microstructure
    Alenka, Mauko
    Tadeja, Muck
    Ana, Mladenovic
    CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (06) : 2380 - 2385
  • [23] 3D Quantitative-Amplified Magnetic Resonance Imaging (3D q-aMRI)
    Terem, Itamar
    Younes, Kyan
    Wang, Nan
    Condron, Paul
    Abderezaei, Javid
    Kumar, Haribalan
    Vossler, Hillary
    Kwon, Eryn
    Kurt, Mehmet
    Mormino, Elizabeth
    Holdsworth, Samantha
    Setsompop, Kawin
    BIOENGINEERING-BASEL, 2024, 11 (08):
  • [25] Quantification of, visualization of, and compensation for brain shift using intraoperative magnetic resonance imaging
    Nimsky, C
    Ganslandt, O
    Cerny, S
    Hastreiter, P
    Greiner, G
    Fahlbusch, R
    NEUROSURGERY, 2000, 47 (05) : 1070 - 1079
  • [26] Automated segmentation of 3D cine cardiovascular magnetic resonance imaging
    Arasteh, Soroosh Tayebi
    Romanowicz, Jennifer
    Pace, Danielle F.
    Golland, Polina
    Powell, Andrew J.
    Maier, Andreas K.
    Truhn, Daniel
    Brosch, Tom
    Weese, Juergen
    Lotfinia, Mahshad
    Van der Geest, Rob J.
    Moghari, Mehdi H.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [27] VISUALIZATION AND QUANTIFICATION OF THE HUMAN BLOOD-FLOW BY MAGNETIC-RESONANCE-IMAGING
    BOESIGER, P
    MAIER, SE
    LIU, KC
    SCHEIDEGGER, MB
    MEIER, D
    JOURNAL OF BIOMECHANICS, 1992, 25 (01) : 55 - 67
  • [28] SNR Analysis of 3D Magnetic Resonance Tomosynthesis (MRT) Imaging
    Kim, Min-Oh
    Kim, Dong-Hyun
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [29] 3D imaging using magnetic resonance tomosynthesis (MRT) technique
    Kim, Min-Oh
    Zho, Sang-Young
    Kim, Dong-Hyun
    MEDICAL PHYSICS, 2012, 39 (08) : 4733 - 4741
  • [30] 3D Plastronics for Smartly Integrated Magnetic Resonance Imaging Coils
    Gerges, Tony
    Semet, Vincent
    Lombard, Philippe
    Gaillard, Sophie
    Cabrera, Michel
    Lambert, Simon Auguste
    FRONTIERS IN PHYSICS, 2020, 8