Radiation safety issues for top-up operation at SPring-8

被引:2
|
作者
Asano, Yoshihiro [1 ]
Takagi, Tetsuya [1 ]
机构
[1] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo 6795198, Japan
关键词
SPring-8; top-up; radiation safety; shielding design; synchrotron radiation; interlock;
D O I
10.1016/j.radmeas.2007.01.015
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Electron beam injection to top-up the stored beam current during the operation of the synchrotron radiation beamlines of an 8GeV class synchrotron radiation facility, SPring-8, has been conducted for about a year. A description of operations during this period and of the safety systems is described here. In order to carry out the top-up operation safely, the two goals were set. One is that the electron beam shall never be allowed to invade into the beamlines during the operation. The other is that the dose rate outside the shield tunnel due to beam loss shall never be allowed to exceed set limits during the operations including top-up. To achieve these two goals, suitable guidelines for accelerator operation were decided and the interlock systems were reconstructed. Under these conditions the safety analyses were performed, and it was found that top-up operation was executed without any trouble during this period. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S236 / S241
页数:6
相关论文
共 50 条
  • [21] A preliminary study of beam instabilities in top-up operation at Taiwan light source
    Chou, P. J.
    Chang, H. P.
    Hsu, K. T.
    Hu, K. H.
    Kuo, C. C.
    Luo, G. H.
    Wang, M. H.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 244 - 246
  • [22] Tracking studies of top-up injection for a safe operation of the ESRF-EBS
    Liuzzo, S. M.
    Berkvens, P.
    Carmignani, N.
    Chavanne, J.
    Farvacque, L.
    Versteegen, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 991
  • [23] Characteristics of shielding design calculation for the SPring-8 synchrotron radiation beamlines
    Asano, Y
    Sasamoto, N
    RADIATION PROTECTION DOSIMETRY, 1999, 82 (03) : 167 - 174
  • [24] Quick XAFS system using quasimonochromatic undulator radiation at SPring-8
    Uruga, T.
    Tanida, H.
    Inoue, K.
    Yamazaki, H.
    Irie, T.
    X-RAY ABSORPTION FINE STRUCTURE-XAFS13, 2007, 882 : 914 - +
  • [25] Experimental studies of the microangioarchitecture of tumors using synchrotron radiation at SPring-8
    Yamashita, T
    Imai, S
    Maehara, N
    Kajihara, Y
    Umetani, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1346 - 1348
  • [26] Refraction-contrast imaging using undulator radiation at SPring-8
    Suzuki, Y
    Yagi, N
    Umetani, K
    Kohmura, Y
    Yamasaki, K
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 13 - 22
  • [27] Refraction-contrast imaging using undulator radiation at SPring-8
    Suzuki, Y.
    Yagi, N.
    Umetani, K.
    Kohmura, Y.
    Yamasaki, K.
    Proceedings of SPIE - The International Society for Optical Engineering, 3770 : 13 - 22
  • [28] Improvement of the Micro-pulse Structure for Top-up Operation at the Pohang Light Source
    Hwang, Ilmoon
    Kim, Changbum
    Son, Yoon-Kyoo
    Chun, Myung-Hwan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 590 - 593
  • [29] Toward operation of series IDs at BL43LXU of SPring-8
    Baron, A. Q. R.
    Tanaka, T.
    Soutome, K.
    Takao, M.
    Nakamura, T.
    Kobayashi, K.
    Fujita, T.
    Takahashi, S.
    Aoyagi, H.
    Shimosaki, Y.
    Seike, T.
    Uchiyama, H.
    Ishikawa, D.
    Chuang, T. -H.
    Kimura, H.
    Tanaka, H.
    Kitamura, H.
    Ishikawa, T.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [30] Extended top-up service and clinical pharmacy improve rationality and safety of drug use
    Kjeldsen, Lene Juel
    Nielsen, Ulla Tovgaard
    Vestergaard, Pia
    EJHP PRACTICE, 2010, 16 (04): : 39 - 44