Use of high-performance liquid chromatography-UV and gas chromatography-mass spectrometry for determination of the imidacloprid content of honeybees, pollen, paper filters, grass, and flowers

被引:49
|
作者
Rossi, S
Sabatini, AG
Cenciarini, R
Ghini, S
Girotti, S
机构
[1] Univ Bologna, Ist Sci Chim, I-40127 Bologna, Italy
[2] Ist Nazl Apicoltura, I-40128 Bologna, Italy
[3] Ctr Studi Ambientali, I-47900 Rimini, Italy
关键词
column liquid chromatography-UV; gas chromatography-mass spectrometry; 6-chloronicotinic acid; imidacloprid; honeybees;
D O I
10.1365/s10337-004-0474-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Imidacloprid is a new insecticide with a wide range of action. Because honeybees are very sensitive to this substance, two techniques (HPLC-UV and GC-MS) which enable its detection in several matrices of both animal and vegetable origin were used to monitor its possible presence in cultivated land. in the first method quantification of imidacloprid in honeybees was achieved 1 by use of the external standard method; the detection limit was 50 mg kg(-1), the linear range 0.05-1 mg mL(-1), recovery 60-83%, and the imprecision (coefficient of variation) 8.6% for repeatability and 11.8% for reproducibility. Recovery from pollen was 71-98% in the range 0.05-0.5 mg kg(-1). The repeatability was 9.2-13.9%. Imidacloprid can often be found in the environment, not as a simple molecule but as a group of degradation products. The GC-MS method could be used to quantify all these species as oxidation products and to determine the initial quantity of imiclacloprid by use of a conversion factor. The liquid chromatographic analysis could be used to detect, in a standard solution, 10 ng mL(-1) clerivatized 6-chloronicotinic acid. The linearity was good (R = 0.999) over a wide concentration range (10 Lg mL(-1)-10 ng mL(-1)). Several samples with different matrices (filter paper placed on an pneumatic corn seed drill, grass, flowers, honeybees, etc.) obtained during the sowing period for imidacloprid-treated corn were analyzed. The quantification limit (LOQ) was 0.005 mg kg(-1) for grass and flowers, 0.002 mg kg(-1) for honeybees, and 0.024 mg kg(-1) for paper filters.
引用
收藏
页码:189 / 195
页数:7
相关论文
共 50 条
  • [41] Determination of Caseinomacropeptide in Brazilian Bovine Milk by High-performance Liquid Chromatography-Mass Spectrometry
    Lenardon, Layane
    Meneghini, Leonardo Zanchetti
    Hoff, Rodrigo Barcellos
    Campos Motta, Tanara Magalhaes
    Pizzolato, Tania Mara
    Ferrao, Marco Flores
    Bergold, Ana Maria
    ANALYTICAL LETTERS, 2017, 50 (13) : 2068 - 2077
  • [42] High-performance liquid chromatography-mass spectrometry method for the determination of paroxetine in human plasma
    Zhu, ZM
    Neirinck, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02): : 295 - 300
  • [43] Determination of paclitaxel and related diterpenoids in plant extracts by high-performance liquid chromatography with UV detection in high-performance liquid chromatography mass spectrometry
    Theodoridis, G
    Laskaris, G
    de Jong, CF
    Hofte, AJP
    Verpoorte, R
    JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) : 297 - 305
  • [44] The bridge between thin layer chromatography-mass spectrometry and high-performance liquid chromatography-mass spectrometry: The realization of liquid thin layer chromatography-mass spectrometry (LTLC-MS)
    Li, Yafeng
    Wang, Jianing
    Zhan, Lingpeng
    Wleklinski, Michael
    Wang, Jiyun
    Xiong, Caiqiao
    Liu, Huihui
    Zhou, Yueming
    Nie, Zongxiu
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1460 : 181 - 189
  • [45] Study on the photostability of guaiazulene by high-performance liquid chromatography/mass spectrometry and gas chromatography/mass spectrometry
    Fiori, Jessica
    Gotti, Roberto
    Albini, Angelo
    Cavrini, Vanni
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (17) : 2698 - 2706
  • [46] USE OF HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY FOR THE STUDY OF THE METABOLISM OF RANITIDINE IN MAN
    MARTIN, LE
    OXFORD, J
    TANNER, RJN
    JOURNAL OF CHROMATOGRAPHY, 1982, 251 (02): : 215 - 224
  • [47] Determination of deoxynivalenol in cereal grains by high performance liquid chromatography and verified by high performance liquid chromatography-mass spectrometry
    Sui, K
    Li, J
    Wei, F
    Zhao, SC
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (11) : 1643 - 1646
  • [48] Measurement of 8-hydroxy-2′-deoxyguanosine in DNA by high-performance liquid chromatography-mass spectrometry:: comparison with measurement by gas chromatography-mass spectrometry
    Dizdaroglu, M
    Jaruga, P
    Rodriguez, H
    NUCLEIC ACIDS RESEARCH, 2001, 29 (03)
  • [49] Determination of benzoyl peroxide and benzoic acid in wheat flour by high-performance liquid chromatography and its identification by high-performance liquid chromatography-mass spectrometry
    Abe-Onishi, Y
    Yomota, C
    Sugimoto, N
    Kubota, H
    Tanamoto, K
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1040 (02) : 209 - 214
  • [50] ANALYSIS OF SELECTED PESTICIDES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
    VOYKSNER, RD
    BURSEY, JT
    PELLIZZARI, ED
    JOURNAL OF CHROMATOGRAPHY, 1984, 312 (NOV): : 221 - 235