Phasor-based fault location algorithm for three-end multi-section nonhomogeneous parallel transmission lines

被引:10
|
作者
Saber, Ahmed [1 ]
Bhalja, Bhavesh R. [2 ]
机构
[1] Cairo Univ, Elect Power Engn Dept, Giza, Egypt
[2] Indian Inst Technol, Dept Elect Engn, Roorkee, Uttar Pradesh, India
关键词
Current phasors; Fault location; Transmission lines; LOCALIZATION TECHNIQUE; SCHEME; VOLTAGE;
D O I
10.1016/j.ijepes.2021.106958
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to estimate the fault location on three-terminal multi-section mixed nonhomogeneous transmission lines, all the previously published algorithms utilize the synchronized voltage and current measurements at all ends. In this article, a fault location algorithm for three-terminal multi-section mixed double-circuit untransposed transmission lines is presented utilizing only unsynchronized current measurements. Considering issues related to the shunt capacitance, un-transposition of the line, and mutual couplings between all phases, a threshold free identification algorithm is developed to differentiate the faulted line branch. In addition, analytical fault location equation is deduced independent of fault resistance and fault type. The three-terminal power system is modeled using MATLAB environment, and several fault cases are conducted, including all fault types, different fault resistances and locations, as well as different fault inception angles. The introduced work shows high accuracy under the effect of measurement and synchronization errors as well as line parameters errors.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Time-time-transform-based fault location algorithm for three-terminal transmission lines
    Ahmadimanesh, Alireza
    Shahrtash, Seyyed Mohammad
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (05) : 464 - 473
  • [32] Time-domain fault location algorithm based on one-terminal current of parallel transmission lines
    School of Electric Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    Zhongguo Dianji Gongcheng Xuebao, 2007, 7 (52-57):
  • [33] PMU-based Fault Location Technique for Three-terminal Parallel Transmission Lines with Series Compensation
    Saber, Ahmed
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2020, 48 (4-5) : 410 - 422
  • [34] Single-end current-based algorithm for fault location in series capacitor compensated transmission lines
    Taheri, Reyhaneh
    Eslami, Mahdiyeh
    Damchi, Yaser
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 123
  • [35] A phasor-distance based faulty phase detection and fault classification technique for parallel transmission lines
    Kothari, Nishant
    Bhalja, Bhavesh R.
    Pandya, Vivek
    Tripathi, Pushkar
    Jena, Soumitri
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2020, 21 (04):
  • [36] Time-domain fault location algorithm for parallel transmission lines using unsynchronized currents
    Jiale, S
    Song, GB
    Xu, QQ
    Chao, Q
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2006, 28 (04) : 253 - 260
  • [37] An accurate fault location algorithm for parallel transmission lines using one-terminal data
    Song Guobing
    Jiale, Suonan
    Ge Yaozhong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2009, 31 (2-3) : 124 - 129
  • [38] Extended Fault Location Algorithm Using the Estimated Remote Source Impedance for Parallel Transmission Lines
    Ryu, Jeong-Hun
    Kang, Sang-Hee
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (06) : 2212 - 2219
  • [39] Practical fault location algorithm for multi-terminal transmission lines with radial structure
    Shu, Hongchun
    Chen, Xueyun
    Xu, Chengbin
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 1998, 22 (02):
  • [40] A new scheme for fault location of three-terminal parallel transmission lines without transposer
    Chen, Gonggui
    Cai, Daiying
    Long, Hongyu
    Long, Yi
    Zeng, Xianjun
    Zhou, Ping
    Kang, Peng
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (17) : 2473 - 2487