Retrospective Comparison of Postinsertion Maintenances Between Conventional and 3D Printed Complete Dentures Fabricated in a Predoctoral Clinic

被引:16
|
作者
Kim, Tae Hyung [1 ]
Huh, Jung Bo [2 ]
Lee, Janet [3 ]
Bae, Eun-Bin [4 ]
Park, Cheryl J. [5 ]
机构
[1] Univ Southern Calif, Removable Prosthodont, Div Restorat Sci, Herman Ostrow Sch Dent, Los Angeles, CA 90007 USA
[2] Pusan Natl Univ, Sch Dent, Inst Dent Res, Inst Translat Dent Sci,Dept Prosthodont, Yangsan, South Korea
[3] Univ Penn, Philadelphia, PA 19104 USA
[4] Pusan Natl Univ, Sch Dent, Inst Translat Dent Sci, Dept Prosthodont, Yangsan, South Korea
[5] Univ Southern Calif, Div Restorat Sci, Herman Ostrow Sch Dent, Los Angeles, CA 90007 USA
关键词
3D Printed denture; digital denture comparison; printed denture performance; ENGINEERED COMPLETE DENTURES; PERFORMANCE; IMPRESSION;
D O I
10.1111/jopr.13322
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A retrospective study to analyze the clinical performance of 3D printed complete dentures in edentulous patients compared with conventional complete dentures regarding postinsertion visits and patient reported outcomes. Material and Methods Electronic charts were reviewed to analyze 420 (maxilla 270, mandible 150) heat-polymerized conventional complete dentures (CCD) inserted between July 1, 2015 and June 30, 2016 and 217 (maxilla 130, mandible 86) 3D printed complete dentures (PCD) inserted between July 1, 2017 and June 30, 2018. Number of remakes, number of postinsertion adjustments, type and number of repairs, and patient reported complications were compared between two types of complete dentures. The frequency of denture repair and patient reported complications were analyzed using chi-square of independence test. Results The frequency of pain and visible ulcer lesions in the maxilla was determined to be 46.67% with CCD and 36.15% in PCD (p = 0.047). There was no statistical significance in other items. The majority of esthetic concerns was dissatisfaction with the shape of dentures with CCD (4.67%) and they had statistically significant, less frequent, esthetic problems than PCD (11.63%) (p = 0.047). Conclusions Similar clinical performance was recorded between the two groups, but the overall pain and visible ulcer lesions were less in the printed complete dentures then the conventionally processed dentures. However, the esthetic aspect was better in conventionally processed complete dentures.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 50 条
  • [1] Comparison of nonscheduled, postinsertion adjustment visits for complete dentures fabricated with conventional and CAD-CAM protocols: A clinical study
    Drago, Carl
    Borgert, Andrew J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (05): : 459 - 466
  • [2] Trueness and fitting accuracy of maxillary 3D printed complete dentures
    Yoshidome, Kazuki
    Torii, Mana
    Kawamura, Noboru
    Shimpo, Hidemasa
    Ohkubo, Chikahiro
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (04) : 559 - 564
  • [3] Comparison between Conventional PMMA and 3D Printed Resins for Denture Bases: A Narrative Review
    Dimitrova, Mariya
    Corsalini, Massimo
    Kazakova, Rada
    Vlahova, Angelina
    Chuchulska, Bozhana
    Barile, Giuseppe
    Capodiferro, Saverio
    Kazakov, Stoyan
    JOURNAL OF COMPOSITES SCIENCE, 2022, 6 (03):
  • [4] Durability of 3D Printed Concrete: A Comparison of Extrusion 3D Printing, Shotcrete 3D Printing and Conventional Casting
    Boehler, David
    Mai, Inka
    Lowke, Dirk
    FOURTH RILEM INTERNATIONAL CONFERENCE ON CONCRETE AND DIGITAL FABRICATION, DC 2024, 2024, 53 : 283 - 290
  • [5] Adhesion of Conventional, 3D-Printed and Milled Artificial Teeth to Resin Substrates for Complete Dentures: A Narrative Review
    Tzanakakis, Emmanouil-George
    Pandoleon, Panagiotis
    Sarafianou, Aspasia
    Kontonasaki, Eleana
    POLYMERS, 2023, 15 (11)
  • [6] Fit of removable partial denture frameworks fabricated from 3D printed patterns versus the conventional method: An in vitro comparison
    Rokhshad, Rata
    Tehrani, Azita Mazaheri
    Nahidi, Reza
    Zarbakhsh, Arash
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1144 - 1149
  • [7] The Effect of Build Orientation on the Dimensional Accuracy of 3D-Printed Mandibular Complete Dentures Manufactured with a Multijet 3D Printer
    Gao, Hanqi
    Yang, Zhen
    Lin, Wei-Shao
    Tan, Jianguo
    Chen, Li
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (08): : 684 - 689
  • [8] Trueness of maxillary complete dentures duplicated by using conventional and 3D printing techniques: A comparative in vitro study
    Farahat, Amany Mostafa Saad
    Refai, Omnia M.
    Elsherbeeny, Yasmine Said
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03):
  • [9] Intaglio surface trueness of dentures bases fabricated with 3D printing vs. conventional workflow: a clinical study
    Faur, Andrei-Bogdan
    Rotar, Raul Nicolae
    Jivanescu, Anca
    BMC ORAL HEALTH, 2024, 24 (01):
  • [10] Quantitative evaluation of edentulous maxillomandibular relationship record using diagnostic complete dentures fabricated by CAD and 3D printing
    Li, Weiwei
    Xie, Qiufei
    Wang, Yong
    Sun, Yuchun
    JOURNAL OF ORAL SCIENCE, 2022, 64 (01) : 59 - 62