The Effect of Build Orientation on the Dimensional Accuracy of 3D-Printed Mandibular Complete Dentures Manufactured with a Multijet 3D Printer

被引:24
|
作者
Gao, Hanqi [1 ]
Yang, Zhen [1 ]
Lin, Wei-Shao [2 ]
Tan, Jianguo [1 ]
Chen, Li [1 ]
机构
[1] Peking Univ Sch & Hosp Stomatol, Dept Prosthodont, Natl Clin Res Ctr Oral Dis, Natl Engn Lab Digital & Mat Technol Stomatol,Beij, Beijing, Peoples R China
[2] Indiana Univ, Sch Dent, Dept Prosthodont, Indianapolis, IN USA
基金
中国国家自然科学基金;
关键词
3D Printing; build orientation; complete removable dental prosthesis; MJP technology;
D O I
10.1111/jopr.13330
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare the dimensional accuracy of 3D-printed mandibular complete dentures with different build orientations. Material and Methods A mandibular complete denture was digitized as a virtual reference file. The reference file was 3D-printed at the 0 degrees, 45 degrees, and 90 degrees build orientations with a MultiJet 3D printer (Projet MJP 3600 Dental, 3D systems, Rock Hill, SC). A total of 27 complete dentures were 3D-printed with 9 samples for each orientation. All printed dentures were digitized and separated into teeth, denture extension and intaglio test surfaces. The dimensional accuracy (in root mean square, RMS) was evaluated by comparing whole denture and 3 test surfaces with the reference file. One-way analysis of variance (ANOVA) and a Post-Hoc all pairs Bonferroni test were used to determine statistical differences (alpha = 0.05). Results For the dimensional accuracy on whole denture, the 45 degrees build orientation group showed the smallest RMS (0.170 +/- 0.043 mm) than those of the 0 degrees build orientation group (0.185 +/- 0.060 mm, p < 0.001) and 90 degrees build orientation group (0.183 +/- 0.044 mm, p < 0.001). For the dimensional accuracy on the teeth, denture extension and intaglio test surfaces, the 45 degrees build orientation group also show the smallest RMS values (0.140 +/- 0.044 mm at teeth surface, 0.176 +/- 0.058 mm at denture extension and 0.207 +/- 0.006 mm at intaglio surface). The 0 degrees and 90 degrees build orientation groups had similar accuracy at the teeth (0.149 +/- 0.056 mm versus 0.154 +/- 0.056 mm, p = 0.164) and denture extension surfaces (0.200 +/- 0.025 mm vs 0.196 +/- 0.013 mm, p = 1.000). However, 0 degrees build orientation group (0.228 +/- 0.010 mm) has significantly higher RMS values then those of 90 degrees build orientation group (0.218 +/- 0.057 mm) in the intaglio surface (p = 0.032). The teeth surfaces were most accurate in each build orientation groups, while the intaglio surfaces were least accurate. Conclusions The build orientation affected the dimensional accuracy of 3D-printed mandibular complete dentures, and the 45 degrees build orientation resulted in the most accurate 3D-printed denture from a MultiJet 3D printer.
引用
收藏
页码:684 / 689
页数:6
相关论文
共 50 条
  • [1] Investigating mechanical properties of 3D printed parts manufactured in different orientations on multijet printer
    Chand R.
    Sharma V.S.
    Trehan R.
    [J]. International Journal of Mechatronics and Manufacturing Systems, 2021, 14 (02) : 164 - 179
  • [2] Trueness and fitting accuracy of maxillary 3D printed complete dentures
    Yoshidome, Kazuki
    Torii, Mana
    Kawamura, Noboru
    Shimpo, Hidemasa
    Ohkubo, Chikahiro
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (04) : 559 - 564
  • [3] Evaluation of Accuracy and Position of Milled and 3D-Printed Teeth in Digital Complete Dentures
    Al Sayed El Saaedi, Tarek Mohamed
    Thabet, Yasmine Galaleldin
    Sabet, Marwa Ezzat
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (06) : 781 - 786
  • [4] Effect of Printing Direction on the Accuracy of 3D-Printed Dentures Using Stereolithography Technology
    Hada, Tamaki
    Kanazawa, Manabu
    Iwaki, Maiko
    Arakida, Toshio
    Soeda, Yumika
    Katheng, Awutsadaporn
    Otake, Ryosuke
    Minakuchi, Shunsuke
    [J]. MATERIALS, 2020, 13 (15) : 1 - 12
  • [5] 3D-printed CAD/CAM complete dentures - Case report
    Gomes, Isabel
    Martins, Joao Paulo
    Branco, Catia
    Lopes, Luis Miguel
    [J]. REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2024, 65 (02): : 85 - 93
  • [6] Primary Exploration of the Clinical Application of 3D-Printed Complete Dentures
    Liu, Yu-Xiao
    Yu, Shu-Juan
    Huang, Xiao-Yan
    Lin, Fei-Fei
    Zhu, Guo-Xiong
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (06) : 809 - 814
  • [7] PROPERTIES OF 3D-PRINTED COMPLETE DENTURES - CLARIFIED AND UNCLARIFIED ASPECTS
    Pavlova, Zhanina
    [J]. ANNALS OF DENTAL SPECIALTY, 2023, 11 (04): : 77 - 86
  • [8] Effect of build orientation on the mechanical reliability of 3D printed ABS
    Keles, Ozgur
    Blevins, Caleb Wayne
    Bowman, Keith J.
    [J]. RAPID PROTOTYPING JOURNAL, 2017, 23 (02) : 320 - 328
  • [9] Complete Additively Manufactured (3D-Printed) Electrochemical Sensing Platform
    Richter, Eduardo M.
    Rocha, Diego P.
    Cardoso, Rafael M.
    Keefe, Edmund M.
    Foster, Christopher W.
    Munoz, Rodrigo A. A.
    Banks, Craig E.
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (20) : 12844 - 12851
  • [10] Effect of build orientation in accuracy, flexural modulus, flexural strength, and microhardness of 3D-Printed resins for provisional restorations
    de Castro, Eduardo F.
    Nima, Gabriel
    Rueggeberg, Frederick A.
    Giannini, Marcelo
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 136