Development and fit-for-purpose validation of a LC-MS/MS assay for fibrinogen peptide A quantitation in human plasma

被引:5
|
作者
Lin, Mingxiang [1 ]
Lassman, Michael E. [1 ]
Weiner, Russell [1 ]
Laterza, Omar F. [1 ]
机构
[1] Merck Res Labs, Clin Dev Lab, Rahway, NJ 07065 USA
关键词
D O I
10.4155/bio.14.148
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Fibrinopeptide A (FPA) is a plasma peptide, formed by the action of thrombin on fibrinogen during clog formation. FPA represents a direct indicator of thrombin activity and could potentially be used as a biomarker for anti-thrombotic therapy development. Results/Methodology: A LC-MS/MS assay with a high throughput solid phase extraction procedure was developed and validated to measure FPA in plasma. The lower limit-of-quantitation (LLOQ) of this assay was determined to be 0.16 nM. The inter- and intra-day%CV was <15%. Freeze-thaw stability of FPA was +/- 30% up to 3 cycles and linear response of FPA was observed for plasma dilution up to 16-fold. Conclusion: The assay was validated and the biological variability of FPA in plasma was established (1-30 nM).
引用
收藏
页码:1759 / 1766
页数:8
相关论文
共 50 条
  • [21] LC-MS/MS assay for the quantitation of the ribonucleotide reductase inhibitor triapine in human plasma
    Matsumoto, Julia
    Kiesel, Brian F.
    Parise, Robert A.
    Guo, Jianxia
    Taylor, Sarah
    Huang, Marilyn
    Eiseman, Julie L.
    Ivy, S. Percy
    Kunos, Charles
    Chu, Edward
    Beumer, Jan H.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 146 : 154 - 160
  • [22] Validation of a novel LC-MS/MS method for the quantitation of colistin A and B in human plasma
    Dotsikas, Yannis
    Markopoulou, Catherine K.
    Koundourellis, John E.
    Loukas, Yannis L.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) : 37 - 45
  • [23] Fit-for-purpose in veterinary drug residue analysis: Development and validation of an LC-MS/MS method for the screening of thirty illicit drugs in bovine urine
    Leporati, Marta
    Capra, Pierluigi
    Brizio, Paola
    Ciccotelli, Valentina
    Abete, Maria Cesarina
    Vincenti, Marco
    [J]. JOURNAL OF SEPARATION SCIENCE, 2012, 35 (03) : 400 - 409
  • [24] Development and validation of an LC-MS/MS Method for the quantitation of heparan sulfate in human urine
    Wang, Kai
    Li, Ming
    Xiao, Yijin
    Ma, Mark
    Hu, Wei
    Liang, Tao
    Lin, Zhongping John
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (10)
  • [25] Development and validation of an LC-MS/MS assay for tenofovir and tenofovir alafenamide in human plasma and cerebrospinal fluid
    Ocque, Andrew J.
    Hagler, Colleen E.
    Morse, Gene D.
    Letendre, Scott L.
    Ma, Qing
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 156 : 163 - 169
  • [26] Development and validation of a simple, selective, and sensitive LC-MS/MS assay for the quantification of remdesivir in human plasma
    Nguyen, Ryan
    Goodell, Jennifer C.
    Shankarappa, Priya S.
    Zimmerman, Sara
    Yin, Tyler
    Peer, Cody J.
    Figg, William D.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1171
  • [27] LC-MS/MS assay for the quantitation of FdCyd and its metabolites FdUrd and FU in human plasma
    Holleran, Julianne L.
    Eiseman, Julie L.
    Parise, Robert A.
    Kummar, Shivaani
    Beumer, Jan H.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 129 : 359 - 366
  • [28] Rapid and sensitive LC-MS/MS assay for the quantitation of 20(S)-protopanaxadiol in human plasma
    Zhang, Dan
    Wang, Yingwu
    Han, Jiangbin
    Yu, Weisong
    Deng, Lili
    Fawcett, J. Paul
    Liu, Zeyuan
    Gu, Jingkai
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (5-6): : 581 - 585
  • [29] Development and validation of a LC-MS/MS assay for quantification of cisplatin in rat plasma and urine
    Shaik, Abdul Naveed
    Altomare, Deborah A.
    Lesko, Lawrence J.
    Trame, Mirjam N.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1046 : 243 - 249
  • [30] Fit-for-purpose LC-MS/MS quantification of leukotoxin and leukotoxin diol in mouse plasma without sample pre-concentration
    Savaryn, John Paul
    Qiu, Xiazi
    Duignan, B. David
    Goess, Christian
    Osman, Sami
    Ji, C. Qin
    Jenkins, Gary
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1180