Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis

被引:4
|
作者
Miyashita, Hirokazu [1 ,2 ]
Moriyama, Noriaki
Yamanaka, Futoshi [3 ]
Saito, Shigeru [3 ]
Lehtola, Heidi [4 ]
Piuhola, Jarkko [4 ]
Niemela, Matti [4 ]
Laine, Mika [1 ,2 ]
机构
[1] Univ Helsinki, Heart & Lung Ctr, Dept Cardiol, Helsinki, Finland
[2] Helsinki Univ Cent Hosp, Helsinki, Finland
[3] Shonan Kamakura Gen Hosp, Dept Cardiol, Kamakura, Kanagawa, Japan
[4] Oulu Univ Hosp, Dept Cardiol, Oulu, Finland
关键词
aortic stenosis; bicuspid aortic valve; conduction disorder; implantation depth; membranous septum length; transcatheter aortic valve replacement; PERMANENT PACEMAKER IMPLANTATION; REPLACEMENT; RISK; OUTCOMES; CALCIFICATION; LENGTH; IMPACT; ROOT;
D O I
10.1111/jce.15525
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Implantation depth and membranous septum (MS) length have been established as the predictors of new-onset conduction disturbance (CD) after transcatheter aortic valve replacement (TAVR) for tricuspid aortic valve (TAV) stenosis. However, little is known about the predictors with bicuspid aortic valve (BAV). This study investigated the role of MS length and implantation depth in predicting CD following TAVR with a balloon-expandable valve in patients with BAV. Methods This retrospective study analyzed 169 patients who underwent TAVR for BAV with balloon-expandable valve, and TAV cohort was established as a control group using propensity score (PS) matching. The primary endpoints were in-hospital new permanent pacemaker implantation (PPI) and new-onset CD (the composite outcome of new-onset left bundle branch block and new PPI). Results PPI developed in 14 patients (8.3%) and new-onset CD in 37 patients (21.9%) in the BAV cohort. Multivariate analysis revealed severe left ventricle outflow tract (LVOT) calcification (odds ratio [OR]: 5.83, 95% confidence interval [CI]: 1.08-31.5, p = .0407) and implantation depth-MS length (OR: 1.30, 95% CI: 1.12-1.51, p = .0005) as the predictors of new-onset CD within the BAV cohort. The matched comparison between BAV and TAV groups showed similar MS length (3.0 vs. 3.2 mm, p = .5307), but valves were implanted more deeply in the BAV group than in the TAV group (3.9 vs. 3.0 mm, p < .0001). New-onset CD was more frequent in patients who had BAV (22.3% vs. 13.9%, p = .0458). Conclusion The implantation depth-MS length, and severe LVOT calcification predicted new-onset CD following TAVR in BAV with balloon-expandable valve. Among BAV patients, THV THV were implanted more deeply compared to THV patients. High deployment technique could be considered to avoid new-onset CD in BAV anatomy.
引用
收藏
页码:1576 / 1586
页数:11
相关论文
共 50 条
  • [41] TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) IN BICUSPID AORTIC STENOSIS
    Wijesinghe, Namal
    Nietlispach, Fabian
    Gurvitch, Ronen
    Tay, Edgar
    Wood, David A.
    Rodes-Cabau, Josep
    Velianou, James L.
    Natarajan, Madhu K.
    Ye, Jian
    Dumont, Eric
    Cheung, Anson
    Webb, John G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [42] The Predictors of Conduction Disturbances Following Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve: A Multicenter Study
    Guo, Yuchao
    Zhou, Dao
    Dang, Mengqiu
    He, Yuxing
    Zhang, Shenwei
    Fang, Jun
    Wu, Shili
    Huang, Qiong
    Chen, Lianglong
    Yuan, Yiqiang
    Fan, Jiaqi
    Jilaihawi, Hasan
    Liu, Xianbao
    Wang, Jian'an
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [43] Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
    Kameshima, Haruka
    Izumo, Masaki
    Suzuki, Tomomi
    Ohara, Hiroshi
    Sato, Yukio
    Watanabe, Mika
    Kuwata, Shingo
    Okuyama, Kazuaki
    Kamijima, Ryo
    Takai, Manabu
    Kou, Seisyou
    Tanabe, Yasuhiro
    Harada, Tomoo
    Akashi, Yoshihiro J.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [44] Balloon-Expandable Prostheses for Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique Barbosa
    Urena, Marina
    Allende, Ricardo
    Amat-Santos, Ignacio J.
    Rodes-Cabau, Josep
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 56 (06) : 583 - 595
  • [45] Late migration of balloon-expandable transcatheter aortic valve
    Lauten, Alexander
    Hamadanchi, Ali
    Doenst, Torsten
    Figulla, Hans R.
    EUROPEAN HEART JOURNAL, 2013, 34 (32) : 2509 - 2509
  • [46] Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Stenosis
    Vincent, Flavien
    Ternacle, Julien
    Denimal, Tom
    Shen, Mylene
    Redfors, Bjorn
    Delhaye, Cedric
    Simonato, Matheus
    Debry, Nicolas
    Verdier, Basile
    Shahim, Bahira
    Pamart, Thibault
    Spillemaeker, Hugues
    Schurtz, Guillaume
    Pontana, Francois
    Thourani, Vinod H.
    Pibarot, Philippe
    Van Belle, Eric
    CIRCULATION, 2021, 143 (10) : 1043 - 1061
  • [47] Transcatheter aortic valve replacement in bicuspid aortic valve stenosis
    Yoon, Sung-Han
    Webb, John G.
    Leon, Martin B.
    Makkar, Raj
    PROGRESS IN CARDIOVASCULAR DISEASES, 2020, 63 (04) : 482 - 487
  • [48] Feasibility and outcomes of transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis
    Pontnau, F.
    Himbert, D.
    Messika-Zeitoun, D.
    Detaint, D.
    Cueff, C.
    Laissy, J. -P.
    Sordi, M.
    Descoutures, F.
    Nataf, P.
    Vahanian, A.
    EUROPEAN HEART JOURNAL, 2012, 33 : 581 - 581
  • [49] Transcatheter aortic valve replacement for bicuspid aortic valve stenosis
    Kayani, Waleed T.
    Blaustein, Alvin
    Denktas, Ali
    Jneid, Hani
    CLEVELAND CLINIC JOURNAL OF MEDICINE, 2018, 85 (10) : 786 - 788
  • [50] Transcatheter Aortic Valve Therapy for Bicuspid Aortic Valve Stenosis
    Dayawansa, Nalin H.
    Noaman, Samer
    Teng, Lung En
    Htun, Nay Min
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (10)