Normalization of local contrast in mammograms

被引:43
|
作者
Veldkamp, WJH [1 ]
Karssemeijer, N [1 ]
机构
[1] Catholic Univ Nijmegen, Dept Radiol, NL-6525 GA Nijmegen, Netherlands
关键词
high-frequency noise; local contrast; mammograms; microcalcification detection;
D O I
10.1109/42.875197
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Equalizing image noise has been shown to be an important step in automatic detection of microcalcifications in digital mammograms. In this study, an accurate adaptive approach for noise equalization is presented and investigated. No additional information obtained from phantom recordings is involved in the method, which makes the approach robust and independent of film type and film development characteristics. Furthermore, it is possible to apply the method on direct digital mammograms as well. In this study, the adaptive approach is optimized by investigating a number of alternative approaches to estimate the image noise. The estimation of high-frequency noise as a function of the grayscale is improved by a new technique for dividing the grayscale in sample intervals and by using a model for additive high-frequency noise. It is shown that the adaptive noise equalization gives substantially better detection results than does a fixed noise equalization. A large database of 245 digitized mammograms with 341 clusters was used for evaluation of the method.
引用
收藏
页码:731 / 738
页数:8
相关论文
共 50 条
  • [41] Local governance of safety and the normalization of behavior
    Pleysier, Stefaan
    [J]. CRIME LAW AND SOCIAL CHANGE, 2015, 64 (4-5) : 305 - 317
  • [42] Local governance of safety and the normalization of behavior
    Stefaan Pleysier
    [J]. Crime, Law and Social Change, 2015, 64 : 305 - 317
  • [43] PERCEIVED LOCAL CONTRAST IS NOT THE MICHELSON CONTRAST
    PELI, E
    GOLDSTEIN, RB
    YOUNG, GM
    [J]. PERCEPTION, 1991, 20 (01) : 79 - 80
  • [44] Accurate seg mentation and contrast measurement of microcalcifications in mammograms: A phantom study
    Veldkamp, WJH
    Karssemeijer, N
    [J]. MEDICAL PHYSICS, 1998, 25 (07) : 1102 - 1110
  • [45] MAMMOGRAMS OBTAINED WITH RHODIUM VS MOLYBDENUM ANODES - CONTRAST AND DOSE DIFFERENCES
    KIMMESMITH, C
    WANG, J
    DEBRUHL, N
    BASIC, M
    BASSETT, LW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (06) : 1313 - 1317
  • [46] Anisotropic local contrast normalization: The role of stimulus orientation and spatial frequency bandwidths in the oblique and horizontal effect perceptual anisotropies
    Hansen, Bruce C.
    Essock, Edward A.
    [J]. VISION RESEARCH, 2006, 46 (26) : 4398 - 4415
  • [47] Detection of calcifications in digital mammograms using wavelet analysis and contrast enhancement
    Salvado, J
    Roque, B
    [J]. 2005 IEEE INTERNATIONAL WORKSHOP ON INTELLIGENT SIGNAL PROCESSING (WISP), 2005, : 200 - 205
  • [48] A Direct Image Contrast Enhancement Algorithm in the Wavelet Domain for Screening Mammograms
    Tang, Jinshan
    Liu, Xiaoming
    Sun, Qingling
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2009, 3 (01) : 74 - 80
  • [49] Development of contrast normalization mechanisms during childhood and adolescence
    Pei, Francesca
    Baldassi, Stefano
    Tsai, Jeffrey J.
    Gerhard, Holly E.
    Norcia, Anthony M.
    [J]. VISION RESEARCH, 2017, 133 : 12 - 20
  • [50] Benefits of contrast normalization demonstrated in neurons and model cells
    Gaudry, Kate S.
    Reinagel, Pamela
    [J]. JOURNAL OF NEUROSCIENCE, 2007, 27 (30): : 8071 - 8079