The assessment of three methods to verify tracheal tube placement in the emergency setting

被引:124
|
作者
Takeda, T
Tanigawa, K
Tanaka, H
Hayashi, Y
Goto, E
Tanaka, K
机构
[1] Hiroshima Univ, Dept Emergency & Crit Care Med, Grad Sch Biomed Sci, Minami Ku, Hiroshima 7348551, Japan
[2] Fukuoka Univ, Sch Med, Dept Emergency & Crit Care Med, Fukuoka 8140180, Japan
关键词
airway management; esophageal detector device; end-tidal carbon dioxide; tracheal intubation; emergency treatment;
D O I
10.1016/S0300-9572(02)00345-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We studied prospectively the reliability of clinical methods, end-tidal carbon dioxide (ETCO2) detection, and the esophageal detector device (EDD) for verifying tracheal intubation in 137 adult patients in the emergency department. Immediately after intubation, the tracheal tube position was tested by the EDD and ETCO2 monitor, followed by auscultation of the chest. The views obtained at laryngoscopy were classified according to the Cormack grade. Of the 13 esophageal intubations that occurred, one false-positive result occurred in the EDD test and auscultation. In the non-cardiac arrest patients (n = 56), auscultation, the ETCO2, and EDD test correctly identified 89.3, 98.2*, and 94.6%* of tracheal intubations, respectively (*, P < 0.05 vs. the cardiac arrest patients). In the cardiac arrest patients (n = 81), auscultation, the ETCO2, and the EDD tests correctly identified 92.6**, 67.9, and 75.3% of tracheal intubations, respectively (**, P < 0.05 vs. EDD and ETCO2). The frequencies of Cormack grade I or 2 were 83.9% in the non-cardiac arrest, and 95.1% in the cardiac arrest patients. In conclusion, the ETCO2 monitor is the most reliable method for verifying tracheal intubation in non-cardiac arrest patients. During cardiac arrest and cardiopulmonary resuscitation, however, negative results by the ETCO2 or the EDD are not uncommon, and clinical methods are superior to the use of these devices. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 50 条
  • [21] Assessment of three placement techniques for individualized positioning of the tip of the tracheal tube in children under the age of 4 years
    Moll, Jens
    Erb, Thomas O.
    Frei, Franz J.
    PEDIATRIC ANESTHESIA, 2015, 25 (04) : 379 - 385
  • [22] Assessment of a New Method to Verify Feeding Tube Placement by Syringe Aspiration in a Porcine Model
    Lin, Hung-Jung
    Foo, Ning-Ping
    Guo, How-Ran
    Lin, Chih-Chan
    Lin, Chun-Chang
    Chen, Kuo-Tai
    INTERNATIONAL JOURNAL OF GERONTOLOGY, 2012, 6 (03) : 220 - 223
  • [23] Bronchospasm and confirmation of tracheal tube placement
    Cox, RG
    ANAESTHESIA, 1999, 54 (05) : 498 - 499
  • [24] VERIFICATION OF TRACHEAL TUBE PLACEMENT - REPLY
    SMITH, EE
    ANNALS OF EMERGENCY MEDICINE, 1995, 26 (04) : 528 - 528
  • [25] Unusual method for tracheal tube placement
    Hooda, S
    Ghai, A
    Mehta, M
    Kumar, R
    TROPICAL DOCTOR, 2003, 33 (01) : 59 - 60
  • [26] CONFIRMATION OF TRACHEAL TUBE PLACEMENT - REPLY
    CHARTERS, P
    WILKINSON, K
    ANAESTHESIA, 1988, 43 (01) : 72 - 72
  • [27] Percutaneous placement of tracheal T tube
    Wood, DE
    Reynolds, B
    Vallières, E
    ANNALS OF THORACIC SURGERY, 1998, 65 (02): : 557 - 558
  • [28] Human factors and clinical assessment: issues in confirming correct tracheal tube placement
    Pandit, J. J.
    Young, P. J.
    Davies, M.
    ANAESTHESIA, 2022, 77 (06) : 720 - 720
  • [29] Tracheal Stent Placement for the Emergency Management of Tracheal Collapse in Dogs
    Beal, Matthew W.
    TOPICS IN COMPANION ANIMAL MEDICINE, 2013, 28 (03) : 106 - 111
  • [30] A comparison of three methods for estimating appropriate tracheal tube depth in children
    Mariano, ER
    Ramamoorthy, C
    Chu, LF
    Chen, M
    Hammer, GB
    PEDIATRIC ANESTHESIA, 2005, 15 (10) : 846 - 851