Anode biofilm influence on the toxic response of microbial fuel cells under different operating conditions

被引:18
|
作者
Xing, Fei [1 ,2 ]
Xi, Hongbo [2 ]
Yu, Yin [2 ]
Zhou, Yuexi [2 ]
机构
[1] Beijing Normal Univ, Coll Water Sci, Beijing 100875, Peoples R China
[2] Chinese Res Inst Environm Sci, State Key Lab Environm Criteria & Risk Assessment, Beijing 100012, Peoples R China
关键词
Microbial fuel cell (MFC); Toxicity; Flow rate; Culture time; SHEAR FORCE; PERFORMANCE; MICROENVIRONMENTS; CONDUCTIVITY; OPTIMIZATION; GENERATION; TRANSPORT; BIOANODE; REMOVAL; ENHANCE;
D O I
10.1016/j.scitotenv.2021.145048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The response ofmicroorganisms inmicrobial fuel cells (MFCs) to toxic compounds under different operating conditions, such as flow rate and culture time, was investigated herein. While it has been reported that MFCs can detect some toxic substances, it is unclear if operating conditions affect MFCs toxicity response. In this study, the toxic response time of MFCs decreased when the flow rate increased from 0.5 mL/min to 2 mL/min and then increased with 5 mL/min. The inhibition rates at 0.5 mL/min, 2 mL/min, and 5 mL/min were 8.4% +/- 1.6%, 45.1% +/- 5.3%, and 4.9% +/- 0.3%, respectively. With the increase of culture time from 7 days to 90 days, the toxic response time of MFCs gradually increased. The inhibition rates at culture times of 7 days, 45 days, and 90 dayswere 45.1%+/- 5.3%, 32.6%+/- 6.6%, and 23.2%+/- 1.3%, respectively. Increasing the culture time will reduce the sensitivity of MFC. The results showed that MFCs can respond quickly at a flow rate of 2 mL/min after cultivation for 7 days. Under these conditions, the power density can reach 1137.0 +/- 65.5 mW/m(2), the relative content of Geobacter sp. is 57%, and the ORP of themultilayers changed from-159.2 +/- 1.6mV to-269.9 +/- 1.7mV within 200 mu m biofilm thickness. These findings show that increasing the flow rate and shortening the culture time are conducive for the toxicity response of MFCs, which will increase the sensitivity of MFCs in practical applications. (c) 2021 Published by Elsevier B.V.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Analysis of microbial diversity in microbial fuel cells under different wastewater
    College of Water Sciences, Beijing Normal University, Beijing 100875, China
    不详
    Zhongguo Huanjing Kexue, 2008, 12 (1068-1073):
  • [22] Effect of Temperature on the Catalytic Ability of Electrochemically Active Biofilm as Anode Catalyst in Microbial Fuel Cells
    Liu, Ying
    Climent, Victor
    Berna, Antonio
    Miguel Feliu, Juan
    ELECTROANALYSIS, 2011, 23 (02) : 387 - 394
  • [23] A miniature microbial fuel cell operating with an aerobic anode chamber
    Ringeisen, Bradley R.
    Ray, Ricky
    Little, Brenda
    JOURNAL OF POWER SOURCES, 2007, 165 (02) : 591 - 597
  • [24] Biofilm distribution and performance of microfluidic microbial fuel cells with different microchannel geometries
    Yang, Yang
    Ye, Dingding
    Li, Jun
    Zhu, Xun
    Liao, Qiang
    Zhang, Biao
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (35) : 11983 - 11988
  • [25] Determination of optimal operating conditions for bioelectrolyte fuel cells using ADH as anode catalyst and solidification of fuel
    Takahashi, Yusuke
    Semizo, Hitoki
    Matsuo, Yasumitsu
    CHEMICAL PHYSICS IMPACT, 2024, 9
  • [26] Computational fluid dynamics analysis in microbial fuel cells with different anode configurations
    Kim, Jiyeon
    Kim, Hongsuck
    Kim, Byunggoon
    Yu, Jaecheul
    WATER SCIENCE AND TECHNOLOGY, 2014, 69 (07) : 1447 - 1452
  • [27] Long term testing of Microbial Fuel Cells: Comparison of different anode materials
    Hidalgo, D.
    Tommasi, T.
    Velayutham, K.
    Ruggeri, B.
    BIORESOURCE TECHNOLOGY, 2016, 219 : 37 - 44
  • [28] Influence of shear stress on electroactive biofilm characteristics and performance in microbial fuel cells
    Godain, Alexiane
    Vogel, Timothy M.
    Fongarland, Pascal
    Haddour, Naoufel
    BIOSENSORS & BIOELECTRONICS, 2024, 244
  • [29] Performance of microbial fuel cells operated under anoxic conditions
    Marks, Stanislaw
    Makinia, Jacek
    Jesus Fernandez-Morales, Francisco
    APPLIED ENERGY, 2019, 250 : 1 - 6
  • [30] Sulfur Poisoning of Ni Anode as a Function of Operating Conditions in Solid Oxide Fuel Cells
    Lee, Ho Seong
    Lee, Hyun Mi
    Lim, Hyung-Tae
    KOREAN JOURNAL OF METALS AND MATERIALS, 2018, 56 (12): : 893 - 899