CT-Guided Fine-Needle Aspiration and Core Needle Biopsies of Pulmonary Lesions: A Single-Center Experience With 750 Biopsies in Japan

被引:86
|
作者
Takeshita, Jumpei [1 ]
Masago, Katsuhiro [1 ]
Kato, Ryoji [1 ]
Hata, Akito [1 ]
Kaji, Reiko [1 ]
Fujita, Shiro [1 ]
Katakami, Nobuyuki [1 ]
机构
[1] Inst Biomed Res & Innovat, Div Integrated Oncol, Chuo Ku, Kobe, Hyogo 6500047, Japan
关键词
core needle biopsy; CT-guided lung biopsy; fine-needle aspiration; pneumothorax; pulmonary lesion; CHEST TUBE PLACEMENT; LUNG-BIOPSY; DIAGNOSTIC-ACCURACY; RISK-FACTORS; 20; MM; PNEUMOTHORAX; FLUOROSCOPY; VARIABLES; NODULES; YIELD;
D O I
10.2214/AJR.14.13151
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. CT-guided lung biopsy is a well-established diagnostic method for pulmonary lesions. The aim of our study was to evaluate the diagnostic outcomes and safety profile of conventional CT-guided lung biopsies. MATERIALS AND METHODS. We retrospectively analyzed the results of CT-guided lung biopsies for 750 patients to determine the diagnostic accuracy, complication rates, and independent risk factors for diagnostic failure and severe pneumothorax. RESULTS. Diagnostic accuracy was 92.9%. Independent risk factors for diagnostic failure were malignant lesions (odds ratio [OR], 4.20; 95% CI, 1.66-14.1; p = 0.001), lesions in the lower lobe (OR, 2.01; 95% CI, 1.17-3.47; p = 0.011), lesions 2.0 cm or smaller (OR, 2.87; 95% CI, 1.59-5.48; p < 0.001), and the presence of pneumothorax during the procedure (OR, 2.18; 95% CI, 1.27-3.78; p = 0.004). Pneumothorax requiring drainage occurred in 7% of patients. Independent risk factors for pneumothorax requiring drainage were age of 73 years or older (OR, 2.19; 95% CI, 1.21-4.05; p = 0.009), the presence of emphysema (OR, 4.29; 95% CI, 2.05-8.82; p < 0.001), benign lesions (OR, 2.33; 95% CI, 1.20-4.40; p = 0.012), supine positioning of the patient (OR, 2.61; 95% CI, 1.44-4.84; p = 0.001), and length from the pleura to the lesion of 1.5 cm or greater (OR, 3.08; 95% CI, 1.63-6.17; p < 0.001). CONCLUSION. CT-guided lung biopsy has a high diagnostic accuracy. Complication rates were acceptable and comparable to those of previous studies.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 50 条
  • [21] Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation
    Li, John
    Weissberg, Zoe
    Bevilacqua, Thomas A.
    Yu, Gordon
    Weber, Kristy
    Sebro, Ronnie
    RADIOLOGIA MEDICA, 2018, 123 (04): : 254 - 259
  • [22] Optimal Diagnostic Yield Achieved With On-site Pathology Evaluation of Fine-Needle Aspiration-Assisted Core Biopsies for Pediatric Osseous Lesions A Single-Center Experience
    Patel, Kalyani
    Kinnear, Darryl
    Quintanilla, Norma M.
    Hicks, John
    Castro, Eumenia
    Curry, Choladda
    Dormans, John
    Ashton, Daniel J.
    Hernandez, J. Alberto
    Wu, Hao
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2017, 141 (05) : 678 - 683
  • [23] Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy
    Beslic, Serif
    Zukic, Fuad
    Milisic, Selma
    RADIOLOGY AND ONCOLOGY, 2012, 46 (01) : 19 - 22
  • [24] CT-guided percutaneous fine-needle aspiration biopsy of small (≤1-cm) pulmonary lesions
    Wallace, MJ
    Krishnamurthy, S
    Broemeling, LD
    Gupta, S
    Ahrar, K
    Morello, FA
    Hicks, ME
    RADIOLOGY, 2002, 225 (03) : 823 - 828
  • [25] CT-guided fine needle aspiration and needle core biopsy of skeletal lesions - Complementary diagnostic techniques
    Koscick, RL
    Petersilge, CA
    Makley, JT
    Abdul-Karim, FW
    ACTA CYTOLOGICA, 1998, 42 (03) : 697 - 702
  • [26] NUCLEAR-CHANGES IN CYTOLOGIC SPECIMENS OBTAINED BY CT-GUIDED FINE NEEDLE ASPIRATION BIOPSIES
    YONEDA, K
    MASON, RL
    MCKINNEY, S
    PULMANO, C
    ACTA CYTOLOGICA, 1990, 34 (06) : 797 - 800
  • [27] Middle mediastinum lesions: Preliminary experience with CT-guided fine-needle aspiration biopsy with a suprasternal approach
    Belfiore, G
    Camera, L
    Moggio, G
    Vetrani, A
    Fraioli, G
    Salvatore, M
    RADIOLOGY, 1997, 202 (03) : 870 - 873
  • [28] Formalin-fixed blood-clot in CT-guided fine needle aspiration biopsies
    Wildberger, JE
    Biesterfeld, S
    Schmitz-Rode, T
    Adam, GB
    Huebner, D
    Ruebben, A
    RADIOLOGY, 1999, 213P : 379 - 379
  • [29] CT-GUIDED NEEDLE BIOPSIES OF PEDIATRIC TUMORS
    ROSSI, P
    CARNEVALE, E
    GUGLIANTINI, P
    PAVONE, P
    PIANCA, C
    TEMPESTA, P
    PEDIATRIC RADIOLOGY, 1984, 14 (04) : 251 - 252
  • [30] The diagnostic accuracy of CT-guided percutaneous core needle biopsy and fine needle aspiration in pulmonary lesions: a meta-analysis
    Zhang, H. -F.
    Zeng, X. -T.
    Xing, F.
    Fan, N.
    Liao, M. -Y.
    CLINICAL RADIOLOGY, 2016, 71 (01) : E1 - E10