Inter-Fraction Tumor Volume Response during Lung Stereotactic Body Radiation Therapy Correlated to Patient Variables

被引:8
|
作者
Salamekh, Samer [1 ]
Rong, Yi [2 ]
Ayan, Ahmet S. [1 ]
Mo, Xiaokui [3 ]
Williams, Terence M. [1 ]
Mayr, Nina A. [4 ]
Grecula, John C. [1 ]
Chakravarti, Arnab [1 ]
Xu-Welliver, Meng [1 ]
机构
[1] Ohio State Univ, Dept Radiat Oncol, Wexner Med Ctr, Columbus, OH 43210 USA
[2] Univ Calif Davis, Dept Radiat Oncol, Sacramento, CA 95817 USA
[3] Ohio State Univ, Wexner Med Ctr, Ctr Biostat, Columbus, OH 43210 USA
[4] Univ Washington, Dept Radiat Oncol, Seattle, WA 98195 USA
来源
PLOS ONE | 2016年 / 11卷 / 04期
关键词
CONE-BEAM CT; TARGET VOLUMES; RADIOTHERAPY SBRT; CANCER; REGRESSION; POSITION;
D O I
10.1371/journal.pone.0153245
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose Analyze inter-fraction volumetric changes of lung tumors treated with stereotactic body radiation therapy (SBRT) and determine if the volume changes during treatment can be predicted and thus considered in treatment planning. Methods and Materials Kilo-voltage cone-beam CT (kV-CBCT) images obtained immediately prior to each fraction were used to monitor inter-fraction volumetric changes of 15 consecutive patients (18 lung nodules) treated with lung SBRT at our institution (45-54 Gy in 3-5 fractions) in the year of 2011-2012. Spearman's (rho) correlation and Spearman's partial correlation analysis was performed with respect to patient/tumor and treatment characteristics. Multiple hypothesis correction was performed using False Discovery Rate (FDR) and q-values were reported. Results All tumors studied experienced volume change during treatment. Tumor increased in volume by an average of 15% and regressed by an average of 11%. The overall volume increase during treatment is contained within the planning target volume (PTV) for all tumors. Larger tumors increased in volume more than smaller tumors during treatment (q = 0.0029). The volume increase on CBCT was correlated to the treatment planning gross target volume (GTV) as well as internal target volumes (ITV) (q = 0.0085 and q = 0.0039 respectively) and could be predicted for tumors with a GTV less than 22 mL. The volume increase was correlated to the integral dose (ID) in the ITV at every fraction (q = 0.0049). The peak inter-fraction volume occurred at an earlier fraction in younger patients (q = 0.0122). Conclusions We introduced a new analysis method to follow inter-fraction tumor volume changes and determined that the observed changes during lung SBRT treatment are correlated to the initial tumor volume, integral dose (ID), and patient age. Furthermore, the volume increase during treatment of tumors less than 22mL can be predicted during treatment planning. The volume increase remained significantly less than the overall PTV expansion, and radiation re-planning was therefore not required for the purpose of tumor control. The presence of the studied correlations suggests that the observed volumetric changes may reflect some underlying biologic process rather than random fluctuations.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Quantification of Tumor Volume Aliasing on Helical CT Scans for Lung Stereotactic Body Radiation Therapy (SBRT) Patients
    Wang, B.
    Kokeny, K. E.
    Rassiah-Szegedi, P.
    Zhao, H.
    Huang, Y.
    Hitchcock, Y. J.
    Joshi, S.
    Salter, B. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S476 - S477
  • [32] Four-Dimensional Computed Tomography Prediction of Inter- and Intrafractional Lung Tumor Motion During Fractionated Stereotactic Body Radiation Therapy
    Forsthoefel, M. K.
    Burlile, J.
    Rashid, A.
    Collins, S. P.
    Collins, B. T.
    Lischalk, J. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E747 - E748
  • [33] Impact of Respiratory Gating on Tumor Position Variability During Stereotactic Body Radiation Therapy for Lung Cancer
    Saito, T.
    Matsuyama, T.
    Toyofuku, T.
    Fukugawa, Y.
    Toya, R.
    Oya, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S510 - S511
  • [34] DOSE-VOLUME ANALYSIS OF RADIATION LUNG INJURY AFTER STEREOTACTIC BODY RADIATION THERAPY
    Masciullo, S.
    Masi, L.
    Casamassima, F.
    Menichelli, C.
    Bonucci, I.
    Doro, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 : S44 - S44
  • [35] Patient outcomes and tumor control in single-fraction versus hypofractionated stereotactic body radiation therapy for spinal metastases
    Park, Christine
    Howell, Elizabeth P.
    Mehta, Vikram A.
    Ramirez, Luis
    Price, Meghan J.
    Floyd, Scott R.
    Kirkpatrick, John P.
    Torok, Jordan
    Abd-El-Barr, Muhammad M.
    Karikari, Isaac O.
    Goodwin, C. Rory
    JOURNAL OF NEUROSURGERY-SPINE, 2021, 34 (02) : 293 - 302
  • [36] The influence of dose and tumor volume on local control following stereotactic body radiation therapy
    Kavanagh, BD
    Zaemisch, R
    Schefter, TE
    Patel, M
    Gravdahl, D
    Zeng, C
    Baron, AE
    Stuhr, K
    Gaspar, LE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S480 - S480
  • [37] The influence of target and patient characteristics on the volume obtained from cone beam CT in lung stereotactic body radiation therapy
    Liu, Hong-Wei
    Khan, Rao
    D'Ambrosi, Rafael
    Krobutschek, Krista
    Nugent, Zoann
    Lau, Harold
    RADIOTHERAPY AND ONCOLOGY, 2013, 106 (03) : 312 - 316
  • [38] Moving towards single fraction peripheral lung stereotactic body radiation therapy: patient care during and after the global COVID-19 pandemic
    Alfaifi, Salem
    Pareek, Vibhay
    Kim, Julian
    Rathod, Shrinivas
    Hunter, William
    Leylek, Ahmet
    Ahmed, Naseer
    Venkataraman, Sankar
    Venugopal, Niranjan
    Chowdhury, Amitava
    Dubey, Arbind
    Kakumanu, Saranya
    Bashir, Bashir
    LUNG CANCER MANAGEMENT, 2024,
  • [39] Quantifying inter and intra-fraction tumor motion using respiration-correlated cone beam CT in lung stereotactic body radiotherapy (SBRT)
    Franks, K. N.
    Purdie, T. G.
    Bezjak, A.
    Moseley, D.
    Pearson, S.
    Jaffrayl, D. A.
    Bissonnette, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S489 - S490
  • [40] On the Dynamic Variability of Abdominal Compression Plate Use on Tumor Motion During Lung Stereotactic Body Radiation Therapy
    Marina, O.
    Wloch, J.
    Jawad, M. S.
    Mangona, V. S.
    Grills, I. S.
    Yan, D.
    Ionascu, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S140 - S141