A method for removing imaging artifact from continuous EEG recorded during functional MRI

被引:994
|
作者
Allen, PJ
Josephs, O
Turner, R
机构
[1] UCL Hosp, Natl Hosp Neurol & Neurosurg, Dept Clin Neurophysiol, London WC1N 3BG, England
[2] UCL, Inst Neurol, Wellcome Dept Cognit Neurol, London, England
关键词
D O I
10.1006/nimg.2000.0599
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Combined EEG/fMRI recording has been used to localize the generators of EEG events and to identify subject state in cognitive studies and is of increasing interest. However, the large EEG artifacts induced during fMRI have precluded simultaneous EEG and fMRI recording, restricting study design. Removing this artifact is difficult, as it normally exceeds EEG significantly and contains components in the EEG frequency range. We have developed a recording system and an artifact reduction method that reduce this artifact effectively. The recording system has large dynamic range to capture both low amplitude EEG and large imaging artifact without distortion (resolution 2 mu V, range 33.3 mV), 5-kHz sampling, and low-pass filtering prior to the main gain stage. Imaging artifact is reduced by subtracting an averaged artifact waveform, followed by adaptive noise cancellation to reduce any residual artifact. This method was validated in recordings from five subjects using periodic and continuous fMRI sequences. Spectral analysis revealed differences of only 10 to 18% between EEG recorded in the scanner without fMRI and the corrected EEG. Ninety-nine percent of spike waves (median 74 mu V) added to the recordings were identified in the corrected EEG compared to 12% in the uncorrected EEG. The median noise after artifact reduction was 8 mu V. All these measures indicate that most of the artifact was removed, with minimal EEG distortion. Using this recording system and artifact reduction method, we have demonstrated that simultaneous EEG/fMRI studies are for the first time possible, extending the scope of EEG/fMRI studies considerably. (C) 2000 Academic Press.
引用
收藏
页码:230 / 239
页数:10
相关论文
共 50 条
  • [1] A New Method for Artifact Removing in EEG Signals
    Araghi, Leila Fallah
    [J]. INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS (IMECS 2010), VOLS I-III, 2010, : 420 - 423
  • [2] A method for removing artefacts from continuous EEG recordings during functional electrical impedance tomography for the detection of epileptic seizures
    Fabrizi, L.
    Yerworth, R.
    McEwan, A.
    Gilad, O.
    Bayford, R.
    Holder, D. S.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) : S57 - S72
  • [3] Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis
    Mantini, D.
    Perrucci, M. G.
    Cugini, S.
    Ferretti, A.
    Romani, G. L.
    Del Gratta, C.
    [J]. NEUROIMAGE, 2007, 34 (02) : 598 - 607
  • [4] EEG and visual evoked potentials recorded simultaneously with FMRI: A validation of artifact removing procedure
    Comi, E.
    Annovazzi, P.
    Martins Silva, A.
    Blasi, V
    Cadioli, M.
    Inuggi, A.
    Cursi, M.
    Falini, A.
    Comi, G.
    Leocani, L.
    [J]. JOURNAL OF PSYCHOPHYSIOLOGY, 2006, 20 (02) : 97 - 97
  • [5] A robust algorithm for removing artifacts in EEG recorded during FMRI/EEG study
    Huang, Chih-Hsu
    Ju, Ming-Shaung
    Lin, Chou-Ching K.
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2012, 42 (04) : 458 - 467
  • [6] Evaluation of a Method of Removing Head Movement Artifact from EEG by Independent Component Analysis and Filtering
    Onikura, Kazuki
    Katayama, Yoshinori
    Iramina, Keiji
    [J]. ADVANCED BIOMEDICAL ENGINEERING, 2015, 4 : 67 - 72
  • [7] Automated pipeline for EEG artifact reduction (APPEAR) recorded during fMRI
    Mayeli, Ahmad
    Al Zoubi, Obada
    Henry, Kaylee
    Wong, Chung Ki
    White, Evan J.
    Luo, Qingfei
    Zotev, Vadim
    Refai, Hazem
    Bodurka, Jerzy
    [J]. JOURNAL OF NEURAL ENGINEERING, 2021, 18 (04)
  • [8] Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
    Gwin, Joseph T.
    Gramann, Klaus
    Makeig, Scott
    Ferris, Daniel P.
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 2010, 103 (06) : 3526 - 3534
  • [9] Removing EOG artifact from the EEG: Adjusting for errors in the correction phase
    Croft, R
    Burgess, A
    Barry, RJ
    [J]. INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2000, 35 (01) : 63 - 63
  • [10] Toothbrushing EEG artifact recorded from chronically implanted subdural electrodes
    Goodkin, Howard P.
    Quigg, Mark
    [J]. NEUROLOGY, 2010, 75 (20) : 1850 - 1850