Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running

被引:371
|
作者
Gwin, Joseph T. [1 ]
Gramann, Klaus [2 ]
Makeig, Scott [2 ]
Ferris, Daniel P. [1 ]
机构
[1] Univ Michigan, Sch Kinesiol, Human Neuromech Lab, Ann Arbor, MI 48109 USA
[2] Univ Calif, Inst Neural Computat, Swartz Ctr Computat Neurosci, La Jolla, CA USA
关键词
EVENT-RELATED POTENTIALS; LONG-RANGE CORRELATIONS; INDEPENDENT COMPONENT ANALYSIS; STRIDE INTERVAL; DYNAMICS; FMRI; GAIT; SEPARATION; QUALITY;
D O I
10.1152/jn.00105.2010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Gwin JT, Gramann K, Makeig S, Ferris DP. Removal of movement artifact from high-density EEG recorded during walking and running. J Neurophysiol 103: 3526-3534, 2010. First published April 21, 2010; doi:10.1152/jn.00105.2010. Although human cognition often occurs during dynamic motor actions, most studies of human brain dynamics examine subjects in static seated or prone conditions. EEG signals have historically been considered to be too noise prone to allow recording of brain dynamics during human locomotion. Here we applied a channel-based artifact template regression procedure and a subsequent spatial filtering approach to remove gait-related movement artifact from EEG signals recorded during walking and running. We first used stride time warping to remove gait artifact from high-density EEG recorded during a visual oddball discrimination task performed while walking and running. Next, we applied infomax independent component analysis (ICA) to parse the channel-based noise reduced EEG signals into maximally independent components (ICs) and then performed component-based template regression. Applying channel-based or channel-based plus component-based artifact rejection significantly reduced EEG spectral power in the 1.5- to 8.5-Hz frequency range during walking and running. In walking conditions, gait-related artifact was insubstantial: event-related potentials (ERPs), which were nearly identical to visual oddball discrimination events while standing, were visible before and after applying noise reduction. In the running condition, gait-related artifact severely compromised the EEG signals: stable average ERP time-courses of IC processes were only detectable after artifact removal. These findings show that high-density EEG can be used to study brain dynamics during whole body movements and that mechanical artifact from rhythmic gait events may be minimized using a template regression procedure.
引用
收藏
页码:3526 / 3534
页数:9
相关论文
共 50 条
  • [1] Independent Component Analysis of Gait-Related Movement Artifact Recorded using EEG Electrodes during Treadmill Walking
    Snyder, Kristine L.
    Kline, Julia E.
    Huang, Helen J.
    Ferris, Daniel P.
    [J]. FRONTIERS IN HUMAN NEUROSCIENCE, 2015, 9
  • [2] A FULLY AUTOMATED METHOD FOR ARTIFACT DETECTION IN HIGH-DENSITY EEG DATA
    Nolan, H.
    Reilly, R. B.
    Whelan, R.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S131 - S131
  • [3] Improved algorithm for ballistocardiac artifact removal from EEG simultaneously recorded with fMRI
    Kim, KH
    Yoon, HW
    Park, HW
    [J]. PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 936 - 939
  • [4] Artifact removal from EEG signals recorded in non-restricted environment
    Jamil, Zainab
    Jamil, Afshan
    Majid, Muhammad
    [J]. BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2021, 41 (02) : 503 - 515
  • [5] Performance-based approach for movement artifact removal from electroencephalographic data recorded during locomotion
    Arad, Evyatar
    Bartsch, Ronny P.
    Kantelhardt, Jan W.
    Plotnik, Meir
    [J]. PLOS ONE, 2018, 13 (05):
  • [6] 'High-Density-SleepCleaner': An open-source, semi-automatic artifact removal routine tailored to high-density sleep EEG
    Leach, Sven
    Sousouri, Georgia
    Huber, Reto
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2023, 391
  • [7] Artifact Removal from EEG Signals Recorded using Low Resolution Emotiv Device
    Sinha, Aniruddha
    Chatterjee, Debatri
    Das, Rajat
    Datta, Shreyasi
    Gavas, Rahul
    Saha, Sanjay Kumar
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC 2015): BIG DATA ANALYTICS FOR HUMAN-CENTRIC SYSTEMS, 2015, : 1445 - 1451
  • [8] Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis
    Mantini, D.
    Perrucci, M. G.
    Cugini, S.
    Ferretti, A.
    Romani, G. L.
    Del Gratta, C.
    [J]. NEUROIMAGE, 2007, 34 (02) : 598 - 607
  • [9] High-density sleep EEG recordings during adolescence
    Huber, R.
    [J]. JOURNAL OF SLEEP RESEARCH, 2008, 17 : 53 - 53
  • [10] Simultaneously Recorded EEG-fMRI: Removal of Gradient Artifacts by Subtraction of Head Movement Related Average Artifact Waveforms
    Sun, Limin
    Hinrichs, Hermann
    [J]. HUMAN BRAIN MAPPING, 2009, 30 (10) : 3361 - 3377