The Effect of Test Distance on Visual Contrast Sensitivity Measured Using the Pelli-Robson Chart

被引:11
|
作者
Njeru, Stevie M. [1 ]
Osman, Mawada [1 ]
Brown, Angela M. [1 ]
机构
[1] Ohio State Univ, Coll Optometry, 338 West 10th Ave, Columbus, OH 43210 USA
来源
基金
美国国家卫生研究院;
关键词
Pelli-Robson (PR); Ohio Contrast Cards (OCCs); contrast sensitivity (CS); low vision; elderly; VALIDATION; DESIGN;
D O I
10.1167/tvst.10.2.32
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Conclusions: PR CS should be measured at a distance in meters that is equal to the patient?s letter acuity in cy/deg, or 1.5?logMAR. Translational Relevance: Contrast sensitivity is highly associated with quality of life, and it is important to measure it accurately. Using a closer distance, or measuring grating CS, can reveal visual abilities missed when patients with low vision are tested using PR at 1 meter. <comment>Superscript/Subscript Available</comment> ABSTRACT Purpose: The Pelli-Robson (PR) chart is widely used to measure clinical contrast sensitivity (CS). It is generally believed that PR testing distance is not critical. Here, we examine whether a closer test distance than the usual 1 meter might be better for patients with low vision. Methods: PR CS was measured on two groups: low-vision students (< 20 years old) and elder patients (> 65 years old). Student PR was measured at 1 meter and at a closer distance d = visual acuity in log10cy/deg (d = 1.5-logMAR). Elder PR was measured at 1 and 3 meters. Grating CS was also measured using the Ohio Contrast Cards (OCCs). Results: Average CS was 0.398 log10 units (over one line on the PR chart) higher at the closer distance than at 1 meter for the students, but there was no effect of 1 vs. 3 meters test distance for the elders. The equivalent spatial frequencies of the PR letters at 1 meter were near the acuity limits of students with low vision, but were near the peak of the elders' CS functions. Especially for students with low vision, PR CS was below OCC CS, even when PR was tested at a closer distance. Conclusions: PR CS should be measured at a distance in meters that is equal to the patient's letter acuity in cy/deg, or 1.5-logMAR. Translational Relevance: Contrast sensitivity is highly associated with quality of life, and it is important to measure it accurately. Using a closer distance, or measuring grating CS, can reveal visual abilities missed when patients with low vision are tested using PR at 1 meter.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Measurement of Contrast Sensitivity Using the M&S Smart System II Compared with the Standard Pelli-Robson Chart in Patients with Primary Pterygium
    Hilmi, Mohd R.
    Khairidzan, Mohd K.
    Azemin, Zulfaezal C.
    Azami, Muhammad H.
    Ariffin, Azrin E.
    MAKARA JOURNAL OF HEALTH RESEARCH, 2018, 22 (03): : 167 - 171
  • [22] How accurate is an LCD screen version of the Pelli-Robson test?
    Zeri, Fabrizio
    Calcatelli, Paolo
    Funaro, Eleonora
    Martelli, Marialuisa
    Naroo, Shehzad A.
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1473 - 1484
  • [23] Converting LEA to Pelli-Robson contrast sensitivity score in neuro-ophthalmology patients
    Prihatningtias, Riski
    Hardiyanti, Disti
    Valencia, Lovenia
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) : S505 - S508
  • [24] Mesopic Pelli-Robson contrast sensitivity and MP-1 microperimetry in healthy ageing and age-related macular degeneration
    Maynard, Michelle L.
    Zele, Andrew J.
    Feigl, Beatrix
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : E772 - E778
  • [25] Effect of Glare vs. Blur on Pelli-Robson, SKILL, and Berkeley Glare tests
    Higgins, KE
    Wood, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 330 - 330
  • [26] Assessment of contrast sensitivity by Spaeth Richman Contrast Sensitivity Test and Peli Robson Chart Test in patients with varying severity of glaucoma
    Thakur, Sahil
    Ichhpujani, Parul
    Kumar, Suresh
    Kaur, Ravneet
    Sood, Sunandan
    EYE, 2018, 32 (08) : 1392 - 1400
  • [27] Comparison of M&S smart system II single letter contrast test and iPad letter test results with Pelli-Robson in Low Vision patients
    Tylka, Barbara
    Saeed, Faheemah
    Kelly, Susan A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [28] SPARCS and Pelli–Robson contrast sensitivity testing in normal controls and patients with cataract
    L Gupta
    V Cvintal
    R Delvadia
    Y Sun
    E Erdem
    C Zangalli
    L Lu
    S S Wizov
    J Richman
    E Spaeth
    G L Spaeth
    Eye, 2017, 31 (5) : 753 - 761
  • [29] The Curve Visible on the Campbell-Robson Chart Is Not the Contrast Sensitivity Function
    Tardif, Jessica
    Watson, Marcus R.
    Giaschi, Deborah
    Gosselin, Frederic
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [30] A NEW CONTRAST SENSITIVITY VISION TEST CHART
    GINSBURG, AP
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1984, 61 (06): : 403 - 407