Performance of the LumiraDx Microfluidic Immunofluorescence Point-of-Care SARS-CoV-2 Antigen Test in Asymptomatic Adults and Children

被引:16
|
作者
Drain, Paul [1 ,2 ]
Sulaiman, Raed [3 ]
Hoppers, Melanie [4 ]
Lindner, Nigel M. [5 ]
Lawson, Vicki [5 ]
Ellis, Jayne E. [5 ]
机构
[1] Univ Washington, Dept Global Hlth, Seattle, WA 98195 USA
[2] Univ Washington, Dept Med, Seattle, WA 98195 USA
[3] Avera Res Inst, Sioux Falls, SD USA
[4] Clin Res Solut, Jackson, TN USA
[5] LumiraDx UK, London, England
关键词
COVID-19; LumiraDx antigen test; RT-PCR; SARS-CoV-2; Sensitivity; Asymptomatic;
D O I
10.1093/ajcp/aqab173
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Objectives The LumiraDx SARS-CoV-2 Ag Test has previously been shown to accurately detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in individuals symptomatic for coronavirus disease 2019 (COVID-19). This evaluation investigated the LumiraDx SARS-CoV-2 Ag Test as an aid in the diagnosis of SARS-CoV-2 infection in asymptomatic adults and children. Methods Asymptomatic individuals at high risk of COVID-19 infection were recruited in 5 point-of-care (POC) settings. Two paired anterior nasal swabs were collected from each participant, tested by using the LumiraDx SARS-CoV-2 Ag Test at the POC, and compared with results from reverse transcription-polymerase chain reaction (RT-PCR) assays (cobas 6800 [Roche Diagnostics] or TaqPath [Thermo Fisher Scientific]). We calculated positive percent agreement (PPA) and negative percent agreement (NPA), then stratified results on the basis of RT-PCR reference platform and cycle threshold. Results Of the 222 included study participants confirmed to be symptom-free for at least 2 weeks before testing, the PPA was 82.1% (95% confidence interval [CI], 64.4%-92.1%). The LumiraDx SARS-CoV-2 Ag Test correctly identified 95.8% (95% CI, 79.8%-99.3%) of the samples confirmed positive in fewer than 33 RT-PCR cycles and 100% (95% CI, 85.1%-100%) in fewer than 30 RT-PCR cycles while maintaining 100% NPA. Conclusions This rapid, high-sensitivity test can be used to screen asymptomatic patients for acute SARS-CoV-2 infection in clinic- and community-based settings.
引用
收藏
页码:602 / 607
页数:6
相关论文
共 50 条
  • [1] Point-of-Care Antigen Test for SARS-CoV-2 in Asymptomatic College Students
    Tinker, Sarah C.
    Szablewski, Christine M.
    Litvintseva, Anastasia P.
    Drenzek, Cherie
    Voccio, Gary E.
    Hunter, Melissa A.
    Briggs, Stephen
    Heida, Debbie E.
    Folster, Jennifer
    Shewmaker, Patricia L.
    Medrzycki, Magdalena
    Bowen, Michael D.
    Bohannon, Caitlin
    Bagarozzi, Dennis Jr Jr
    Petway, Marla
    Rota, Paul A.
    Kuhnert-Tallman, Wendi
    Thornburg, Natalie
    Prince-Guerra, Jessica L.
    Barrios, Lisa C.
    Tamin, Azaibi
    Harcourt, Jennifer L.
    Honein, Margaret A.
    [J]. EMERGING INFECTIOUS DISEASES, 2021, 27 (10) : 2662 - 2665
  • [2] Performance of a Point-of-Care Test for the Rapid Detection of SARS-CoV-2 Antigen
    Stroemer, Annabelle
    Rose, Ruben
    Schaefer, Miriam
    Schoen, Frieda
    Vollersen, Anna
    Lorentz, Thomas
    Fickenscher, Helmut
    Krumbholz, Andi
    [J]. MICROORGANISMS, 2021, 9 (01) : 1 - 11
  • [3] Development and performance of a point-of-care rapid antigen test for detection of SARS-COV-2 variants
    Liu, Lihong
    Meyers, Kathrine
    Purpura, Lawrence J.
    Nguyen, Nadia
    Mohri, Hiroshi
    Chang, Jennifer Y.
    Annavajhala, Medini K.
    Lopez, Leo, III
    Lee, Sang Won
    Shah, Jayesh
    Lane, Benjamin
    Cantos, Anyelina
    Tukuru, Sade A.
    Guo, Yicheng
    Ford, Kenra
    Chiu, Yueh-Ting
    Sheng, Zizhang
    Choesang, Tenzin
    Castor, Delivette
    Wang, Maple
    Pili, Christina
    Van Hoy, Michael N.
    Wallach, Andrew
    Horton, Jamie
    Chen, Zhiqiang
    Rosenthal, Susan
    McLaren, Son
    Jiang, Baowei
    Wang, Frank
    Lu, Helen H.
    Uhlemann, Anne-Catrin
    Ho, David D.
    Yin, Michael T.
    [J]. JOURNAL OF CLINICAL VIROLOGY PLUS, 2022, 2 (03):
  • [4] Performance evaluation of the LumiraDx quantitative microfluidic point-of-care CRP test
    Ellis, Jayne
    Harnett, James
    Cameron, Gregor
    Moss, Phil
    Gray, Alasdair
    [J]. PRACTICAL LABORATORY MEDICINE, 2024, 38
  • [5] Performance Evaluation of the SAMBA II SARS-CoV-2 Test for Point-of-Care Detection of SARS-CoV-2
    Assennato, Sonny M.
    Ritchie, Allyson, V
    Nadala, Cesar
    Goel, Neha
    Tie, Cuijuan
    Nadala, Lourdes M.
    Zhang, Hongyi
    Datir, Rawlings
    Gupta, Ravindra K.
    Curran, Martin D.
    Lee, Helen H.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (01)
  • [6] Usefulness of the Lumiradx™ SARS-COV-2 antigen test in nursing home
    Bergas, Alba
    Rivera, Samuel
    Torrecillas, Miriam
    Cuervo, Guillermo
    [J]. ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2022, 40 (07): : 404 - 405
  • [7] Clinical Evaluation of BD Veritor SARS-CoV-2 Point-of-Care Test Performance Compared to PCR-Based Testing and versus the Sofia 2 SARS Antigen Point-of-Care Test
    Young, Stephen
    Taylor, Stephanie N.
    Cammarata, Catherine L.
    Varnado, Katey G.
    Roger-Dalbert, Celine
    Montano, Amanda
    Griego-Fullbright, Christen
    Burgard, Cameron
    Fernandez, Catherine
    Eckert, Karen
    Andrews, Jeffrey C.
    Ren, Huimiao
    Allen, Joseph
    Ackerman, Ronald
    Cooper, Charles K.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (01)
  • [8] Microfluidic immunoassays for point-of-care testing of SARS-CoV-2 antigens and antibodies
    Li, Cuili
    Zhou, Wan
    Ruiz, Angel Gutierrez
    Mohammadi, Yasaman
    Li, Qingning
    Zhang, Shuting
    Li, Xiujun
    Fu, Guanglei
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 177
  • [9] Performance evaluation of the LumiraDx quantitative microfluidic point-of-care CRP test in pediatric emergency
    Masri, W.
    Djeddou, R.
    Cung, A.
    Vignaud, O.
    Bendaoud, M.
    [J]. CLINICA CHIMICA ACTA, 2024, 558
  • [10] Developing a Point-of-Care Molecular Test to Detect SARS-CoV-2
    Debjani Paul
    Priyanka Naik
    Shomdutta Roy
    [J]. Transactions of the Indian National Academy of Engineering, 2020, 5 (2) : 229 - 232