Improved resolution and signal-to-noise ratio in MRI via enhanced signal digitization

被引:22
|
作者
Elliott, MA [1 ]
Insko, EK [1 ]
Greenman, RL [1 ]
Leigh, JS [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
MRI; dynamic range; digitization noise;
D O I
10.1006/jmre.1997.1319
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The high frequency k-space data in magnetic resonance imaging is often poorly reproduced due to the finite dynamic range of an analog-to-digital converter, The magnitude of this digitization error can equal and even exceed the magnitude of the thermal noise, Under such conditions, attempts to increase image signal-to-noise ratio via signal averaging meet with diminishing success, Because the relative size of the digitization error increases at higher spatial frequencies, a reduction in image resolution is incurred as well. By adjusting the level of the analog signal sampled by the analog-to-digital converter during the course of an imaging experiment, the magnitude of the digitization artifact can be greatly reduced. The results of simulations and imaging experiments are presented which demonstrate that this strategy improves both the signal-to-noise ratio and resolution of magnetic resonance images. (C) 1998 Academic Press.
引用
收藏
页码:300 / 304
页数:5
相关论文
共 50 条
  • [1] Signal-to-noise ratio in MRI
    Redpath, TW
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (847): : 704 - 707
  • [2] Sparse Coding for Improved Signal-to-Noise Ratio in MRI
    Razzaq, Fuleah A.
    Mohamed, Shady
    Bhatti, Asim
    Nahavandi, Saeid
    NEURAL INFORMATION PROCESSING, ICONIP 2014, PT III, 2014, 8836 : 258 - 265
  • [3] The effects of digitization on the elastographic signal-to-noise ratio
    Srinivasan, S
    Kallel, F
    Ophir, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (11-12): : 1521 - 1534
  • [4] IMPROVED SIGNAL-TO-NOISE RATIO IN NEUROPHYSIOLOGY
    VILLOZ, JP
    STEINER, FA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1971, BM18 (04) : 302 - &
  • [5] Ultimate intrinsic signal-to-noise ratio in MRI
    Johns Hopkins University, School of Medicine, Department of Radiology, Baltimore, MD, United States
    不详
    Magn. Reson. Med., 3 (462-473):
  • [6] Ultimate intrinsic signal-to-noise ratio in MRI
    Ocali, O
    Atalar, E
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) : 462 - 473
  • [8] IMPROVED SIGNAL-TO-NOISE RATIO IN LASER VELOCIMETER
    WATRASIEWICZ, BM
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1970, 3 (10): : 823 - +
  • [9] 'Signal-to-Noise Ratio'
    McCooey, D
    POETRY REVIEW, 1999, 89 (01): : 73 - 73
  • [10] Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging
    Sodickson, DK
    Griswold, MA
    Jakob, PM
    Edelman, RR
    Manning, WJ
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (05) : 1009 - 1022