Ultimate intrinsic signal-to-noise ratio in MRI

被引:173
|
作者
Ocali, O [1 ]
Atalar, E [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21287 USA
关键词
SNR optimization; RF coil design; skin effect; focusing;
D O I
10.1002/mrm.1910390317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method to calculate the ultimate intrinsic signal-to-noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant righthand circularly polarized component of the magnetic field at the point of interest. A numerical approximation for the optimal field is found by assuming a superposition of a large number of plane waves. This simulation allowed estimation of the ultimate intrinsic SNR attainable in a human torso model. The performance of six coil configurations was evaluated by comparing the SNR of images obtained by the coils with the ultimate values. In addition, the behavior of ultimate intrinsic SNR was investigated as a function of main field strength. II: was found that the ultimate intrinsic SNR increases better than linearly with the main magnetic field up to 10 T for our model. It was observed that for field strengths of 4 T or higher, focusing is required to reach the ultimate intrinsic SNR.
引用
收藏
页码:462 / 473
页数:12
相关论文
共 50 条
  • [1] Ultimate intrinsic signal-to-noise ratio in MRI
    Johns Hopkins University, School of Medicine, Department of Radiology, Baltimore, MD, United States
    不详
    Magn. Reson. Med., 3 (462-473):
  • [2] Analytic Expressions for the Ultimate Intrinsic Signal-to-Noise Ratio and Ultimate Intrinsic Specific Absorption Rate in MRI
    Kopanoglu, E.
    Erturk, V. B.
    Atalar, E.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (03) : 846 - 858
  • [3] Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations
    Ohliger, MA
    Grant, AK
    Sodickson, DK
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 1018 - 1030
  • [4] Approaching ultimate intrinsic signal-to-noise ratio with loop and dipole antennas
    Lattanzi, Riccardo
    Wiggins, Graham C.
    Zhang, Bei
    Duan, Qi
    Brown, Ryan
    Sodickson, Daniel K.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1789 - 1803
  • [5] Optimizing the intrinsic signal-to-noise ratio of MRI strip detectors
    Kumar, Ananda
    Bottomley, Paul A.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) : 157 - 166
  • [6] Ultimate Intrinsic Signal-to-Noise Ratio of MRI Surface Coils for a Lossy Dielectric Elliptical Cylinder Model
    Liu, Yangqing
    Erricolo, Danilo
    2018 UNITED STATES NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2018,
  • [7] Signal-to-noise ratio in MRI
    Redpath, TW
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (847): : 704 - 707
  • [8] THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING
    EDELSTEIN, WA
    GLOVER, GH
    HARDY, CJ
    REDINGTON, RW
    MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) : 604 - 618
  • [9] The Ultimate Signal-to-Noise Ratio in Realistic Body Models
    Guerin, Bastien
    Villena, Jorge F.
    Polimeridis, Athanasios G.
    Adalsteinsson, Elfar
    Daniel, Luca
    White, Jacob K.
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1969 - 1980
  • [10] Encoding with frames in MRI and analysis of the signal-to-noise ratio
    Xu, ZH
    Chan, AK
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) : 332 - 342