Observational evaluation of outdoor cooling potential of air-source heat pump water heaters

被引:3
|
作者
Yamaguchi, Kazuki [1 ]
Ihara, Tomohiko [2 ]
Kikegawa, Yukihiro [3 ]
机构
[1] Tokyo Elect Power Co Holdings Inc, TEPCO Res Inst, Tsurumi Ku, 4-1 Egasaki Cho, Yokohama, Kanagawa 2308510, Japan
[2] Univ Tokyo, Grad Sch Frontier Sci, 5-1-5 Kashiwanoha, Kashiwa, Chiba 2770882, Japan
[3] Meisei Univ, Sch Sci & Engn, 2-1-1 Hodokubo, Hino, Tokyo 1918506, Japan
关键词
Air-source heat pump water heater; Cold exhaust; Urban heat island; Building-scale climate; Observation; ANTHROPOGENIC HEAT; URBAN CLIMATE; SLEEP STAGES; TEMPERATURE; PERFORMANCE; MITIGATION; IMPACT; ISLAND; TOKYO; MORTALITY;
D O I
10.1007/s00704-021-03673-2
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Heat pump water heaters are highly efficient hot water supply systems that effectively utilize the heat of outdoor air via heat pump technology. Many studies have been conducted to optimize the design and operation of heat pump water heaters from the perspective of climate change mitigation. Air-source heat pump water heaters, which absorb heat from the outdoor air and emit cold exhaust, can also be expected to alleviate the urban heat island effect; however, this has not been studied extensively. To estimate the impact of cold exhaust on building-scale climate, we conducted a multipoint measurement of the outdoor thermal environment around a low-rise apartment building equipped with air-source heat pump water heaters, in both summer and winter. Observations showed a substantial cooling effect that decreased air temperatures by 1 degrees C within the site boundary on summer nights when multiple heat pump water heaters operated concurrently. The analysis revealed that the sensitivity of the ambient temperatures to cold exhaust depends strongly on local atmospheric conditions. The most influential factor was the wind direction: the sensitivity increased significantly when the exhaust outlet location was at the lee side of the building. Naturally, the wind speed also affected the sensitivity, which tended to be higher when the wind speed was lower. The convective stability near the ground surface, however, showed no significant influence over the sensitivity.
引用
收藏
页码:1007 / 1025
页数:19
相关论文
共 50 条
  • [41] Performance improvement of air-source heat pump heating system with variable water temperature difference
    Wang, Wenyi
    Jiang, Jiatong
    Hu, Bin
    Wang, R. Z.
    Luo, Mingwen
    Zhang, Guangpeng
    Xiang, Bo
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [42] Performance of a Ground-Water Assistant Air-source Compound Heat Pump in Refrigerating Conditions
    Zhou, Guanghui
    Liu, Yin
    Chen, Shengjie
    Zhang, Chao
    Guo, Qixun
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 602 - 608
  • [43] Investigation on the air-source chemisorption heat pump for the severely cold regions
    Gao, Peng
    Wang, Liwei
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [44] Proposal and performance evaluation of a solar hybrid heat pump with integrated air-source compression cycle
    Tan, Yingying
    An, Libei
    Wang, Lin
    Hou, Zhaoning
    Zhao, Shuai
    Liu, Bowen
    Guo, Yi
    Energy Conversion and Management, 2024, 321
  • [45] Application of a water-heat storage system for the prevention of duplex defrost using an air-source heat pump
    Lim, K. B.
    Lee, S. H.
    Lee, C. H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2010, 224 (E1) : 67 - 71
  • [46] Applied Research of Solar Assisted Air-Source Heat Pump System
    Lu ChunPing
    Jia YuGui
    Hao CaiXia
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 342 - 345
  • [47] Air-Source Heat Pump with Integrated Latent Heat Storage for Residential Buildings: Concept Development and Design Evaluation
    Bastani, Arash
    Tamasauskas, Justin
    PROCEEDINGS OF THE INTERNATIONAL RENEWABLE ENERGY STORAGE CONFERENCE, IRES 2022, 2023, 16 : 29 - 46
  • [48] Two-stage air-source heat pump for residential heating and cooling applications in northern US climates
    Bertsch, Stefan S.
    Groll, Eckhard A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07): : 1282 - 1292
  • [49] Using statistical tests to compare the coefficient of performance of air source heat pump water heaters
    Tangwe, S.
    Kusakana, K.
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2022, 33 (01) : 40 - 51
  • [50] A performance comparison between an air-source and a ground-source reversible heat pump
    de Swardt, CA
    Meyer, JP
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2001, 47 (08): : 519 - 526