Observational evaluation of outdoor cooling potential of air-source heat pump water heaters

被引:3
|
作者
Yamaguchi, Kazuki [1 ]
Ihara, Tomohiko [2 ]
Kikegawa, Yukihiro [3 ]
机构
[1] Tokyo Elect Power Co Holdings Inc, TEPCO Res Inst, Tsurumi Ku, 4-1 Egasaki Cho, Yokohama, Kanagawa 2308510, Japan
[2] Univ Tokyo, Grad Sch Frontier Sci, 5-1-5 Kashiwanoha, Kashiwa, Chiba 2770882, Japan
[3] Meisei Univ, Sch Sci & Engn, 2-1-1 Hodokubo, Hino, Tokyo 1918506, Japan
关键词
Air-source heat pump water heater; Cold exhaust; Urban heat island; Building-scale climate; Observation; ANTHROPOGENIC HEAT; URBAN CLIMATE; SLEEP STAGES; TEMPERATURE; PERFORMANCE; MITIGATION; IMPACT; ISLAND; TOKYO; MORTALITY;
D O I
10.1007/s00704-021-03673-2
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Heat pump water heaters are highly efficient hot water supply systems that effectively utilize the heat of outdoor air via heat pump technology. Many studies have been conducted to optimize the design and operation of heat pump water heaters from the perspective of climate change mitigation. Air-source heat pump water heaters, which absorb heat from the outdoor air and emit cold exhaust, can also be expected to alleviate the urban heat island effect; however, this has not been studied extensively. To estimate the impact of cold exhaust on building-scale climate, we conducted a multipoint measurement of the outdoor thermal environment around a low-rise apartment building equipped with air-source heat pump water heaters, in both summer and winter. Observations showed a substantial cooling effect that decreased air temperatures by 1 degrees C within the site boundary on summer nights when multiple heat pump water heaters operated concurrently. The analysis revealed that the sensitivity of the ambient temperatures to cold exhaust depends strongly on local atmospheric conditions. The most influential factor was the wind direction: the sensitivity increased significantly when the exhaust outlet location was at the lee side of the building. Naturally, the wind speed also affected the sensitivity, which tended to be higher when the wind speed was lower. The convective stability near the ground surface, however, showed no significant influence over the sensitivity.
引用
收藏
页码:1007 / 1025
页数:19
相关论文
共 50 条
  • [1] Observational evaluation of outdoor cooling potential of air-source heat pump water heaters
    Kazuki Yamaguchi
    Tomohiko Ihara
    Yukihiro Kikegawa
    [J]. Theoretical and Applied Climatology, 2021, 145 : 1007 - 1025
  • [2] A fault detection technique for air-source heat pump water chiller/heaters
    Chen, Youming
    Lan, Lili
    [J]. ENERGY AND BUILDINGS, 2009, 41 (08) : 881 - 887
  • [3] A new method for preventing air-source heat pump water heaters from frosting
    Zhang, Li
    Fujinawa, Takeshi
    Saikawa, Michiyuki
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (05): : 1327 - 1334
  • [4] The performance of split and integrated types air-source heat pump water heaters in South Africa
    Tangwe, Stephen Loh
    Simon, Michael
    Mhundwa, Russel
    [J]. JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2018, 29 (02) : 12 - 20
  • [5] Exergy Analysis of Air-source Heat Pump Water Heater
    Mi Bingjie
    Luo Qinghai
    Chen Guojie
    [J]. PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, 2016, 43 : 197 - 202
  • [6] NEW AIR-SOURCE HEAT PUMP SYSTEM
    MATSUDA, T
    MIYAMOTO, S
    MINOSHIMA, Y
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (08): : 32 - 35
  • [7] Design and analysis of thermoacoustic air source heat pump water heaters
    Prashantha, B. G.
    Kuwar, Yogendra Vasantrao
    Narasimham, G. S. V. L.
    Seetharamu, S.
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2024, 32 (01)
  • [8] Experimental research and operation optimization of an air-source heat pump water heater
    Guo, J. J.
    Wu, J. Y.
    Wang, R. Z.
    Li, S.
    [J]. APPLIED ENERGY, 2011, 88 (11) : 4128 - 4138
  • [9] Research on parallel hot water system of condensing air-source heat pump
    Jiang, Yizheng
    Zeng, Zhiyong
    Bi, Lin
    Liu, Yicai
    [J]. Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2019, 50 (09): : 2310 - 2316
  • [10] Application Analysis of Air-source Heat Pump Unit
    Shao, Zongyi
    Wang, Yufeng
    Fang, Rui
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 661 - 664