Responsiveness of the Electrically Stimulated Cochlear Nerve in Children With Cochlear Nerve Deficiency

被引:49
|
作者
He, Shuman [1 ]
Shahsavarani, Bahar S. [2 ]
McFayden, Tyler C. [3 ]
Wang, Haibo [4 ]
Gill, Katherine E. [5 ]
Xu, Lei [4 ]
Chao, Xiuhua [4 ]
Luo, Jianfen [4 ]
Wang, Ruijie [4 ]
He, Nancy [1 ]
机构
[1] Boys Town Natl Res Hosp, Ctr Hearing Res, 555 North 30th St, Omaha, NE 68131 USA
[2] Univ Nebraska, Dept Special Educ & Commun Disorders, Lincoln, NE USA
[3] Virginia Polytech Inst & State Univ, Dept Psychol, Blacksburg, VA 24061 USA
[4] Shandong Prov Hosp, Dept Otolaryngol Head & Neck Surg, Jinan, Shandong, Peoples R China
[5] Purdue Univ, Dept Speech Language & Hearing Sci, W Lafayette, IN 47907 USA
来源
EAR AND HEARING | 2018年 / 39卷 / 02期
基金
美国国家卫生研究院;
关键词
Cochlear implant; Cochlear nerve; Cochlear nerve deficiency; Electrically evoked auditory compound action potentials; Neural refractoriness; NEUROPATHY SPECTRUM DISORDER; SENSORINEURAL HEARING-LOSS; AMPLITUDE-GROWTH FUNCTIONS; AUDITORY-NERVE; IMPLANT USERS; RESPONSE PROPERTIES; NEURAL EXCITATION; RECOVERY FUNCTION; ACTION-POTENTIALS; ELECTRODE ARRAYS;
D O I
10.1097/AUD.0000000000000467
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: This study aimed to (1) investigate the responsiveness of the cochlear nerve (CN) to a single biphasic-electrical pulse in implanted children with cochlear nerve deficiency (CND) and (2) compare their results with those measured in implanted children with normal-size CNs. Design: Participants included 23 children with CND (CND1 to CND23) and 18 children with normal-size CNs (S1 to S18). All subjects except for CND1 used Cochlear Nucleus cochlear implants with contour electrode arrays in their test ears. CND1 was implanted with a Cochlear Nucleus Freedom cochlear implant with a straight electrode array in the test ear. For each subject, the CN input/output (I/O) function and the refractory recovery function were measured using electrophysiological measures of the electrically evoked compound action potential (eCAP) at multiple electrode sites across the electrode array. Dependent variables included eCAP threshold, the maximum eCAP amplitude, slope of the I/O function, and time-constants of the refractory recovery function. Slopes of I/O functions were estimated using statistical modeling with a sigmoidal function. Recovery time-constants, including measures of the absolute refractory period and the relative refractory period, were estimated using statistical modeling with an exponential decay function. Generalized linear mixed-effect models were used to evaluate the effects of electrode site on the dependent variables measured in children with CND and to compare results of these dependent variables between subject groups. Results: The eCAP was recorded at all test electrodes in children with normal-size CNs. In contrast, the eCAP could not be recorded at any electrode site in 4 children with CND. For all other children with CND, the percentage of electrodes with measurable eCAPs decreased as the stimulating site moved in a basal-to-apical direction. For children with CND, the stimulating site had a significant effect on the slope of the I/O functions and the relative refractory period but showed no significant effect on eCAP threshold and the maximum eCAP amplitude. Children with CND had significantly higher eCAP thresholds, smaller maximum eCAP amplitudes, flatter slopes of I/O functions, and longer absolute refractory periods than children with normal-size CNs. There was no significant difference in the relative refractory period measured in these two subject groups. Conclusions: In children with CND, the functional status of the CN varied along the length of the cochlea. Compared with children with normal-size CNs, children with CND showed reduced CN responsiveness to electrical stimuli. The prolonged CN absolute refractory period in children with CND might account for, at least partially, the observed benefit of using relatively slow pulse rate in these patients.
引用
收藏
页码:238 / 250
页数:13
相关论文
共 50 条
  • [31] Comparison of Two Measurement Paradigms to Determine Electrically Evoked Cochlear Nerve Responses and Their Correlation to Cochlear Nerve Cross-section in Infants and Young Children With Cochlear Implant
    Schrank, Leonhard
    Nachtigaeller, Pascal
    Mueller, Joachim
    Hempel, John-Martin
    Canis, Martin
    Spiegel, Jennifer L.
    Rader, Tobias
    OTOLOGY & NEUROTOLOGY, 2024, 45 (03) : e206 - e213
  • [32] Vestibular nerve deficiency and vestibular function in children with unilateral hearing loss caused by cochlear nerve deficiency
    Tsukada, Keita
    Usami, Shin-ichi
    ACTA OTO-LARYNGOLOGICA, 2021, 141 (09) : 835 - 840
  • [33] The Electrically Evoked Auditory Change Complex Evoked by Temporal Gaps Using Cochlear Implants or Auditory Brainstem Implants in Children With Cochlear Nerve Deficiency
    He, Shuman
    McFayden, Tyler C.
    Shahsavarani, Bahar S.
    Teagle, Holly F. B.
    Ewend, Matthew
    Henderson, Lillian
    Buchman, Craig A.
    EAR AND HEARING, 2018, 39 (03): : 482 - 494
  • [34] Polarity effects on neural responses of the electrically stimulated auditory nerve at different cochlear sites
    Undurraga, Jaime A.
    van Wieringen, Astrid
    Carlyon, Robert P.
    Macherey, Olivier
    Wouters, Jan
    HEARING RESEARCH, 2010, 269 (1-2) : 146 - 161
  • [35] Usefulness of radiological findings for predicting cochlear implantation outcomes in children with cochlear nerve deficiency: a pilot study
    Chao, Xiuhua
    Luo, Jianfen
    Fan, Zhaomin
    Shi, Honglu
    Han, Yuechen
    Wang, Ruijie
    Song, Yujie
    Wang, Guangbin
    Wang, Haibo
    Xu, Lei
    ACTA OTO-LARYNGOLOGICA, 2016, 136 (10) : 1051 - 1057
  • [36] Auditory Brainstem Implantation After Unsuccessful Cochlear Implantation of Children With Clinical Diagnosis of Cochlear Nerve Deficiency
    Colletti, Liliana
    Wilkinson, Eric P.
    Colletti, Vittorio
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2013, 122 (10): : 605 - 612
  • [37] COCHLEAR NERVE DEFICIENCY AS A SIGN OF CHARGE SYNDROME
    Peron, A.
    Park, A.
    Dent, K.
    Palumbos, J. C.
    Clifford, B.
    Hedlund, G.
    Carey, J. C.
    AMERICAN JOURNAL OF MEDICAL GENETICS PART A, 2015, 167 (08) : 1714 - 1715
  • [38] High Prevalence of Cochlear Nerve Deficiency in Pediatric Patients With Cochlear Aperture Stenosis
    Dorismond, Christina
    Smetak, Miriam R.
    Perkins, Elizabeth L.
    Foust, Alexandra M.
    Sarma, Asha
    Virgin, Frank W.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2024, 171 (03) : 872 - 877
  • [39] Cochlear nerve aplasia and cochlear implantation
    Sennaroglu, L
    AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (05): : 771 - 771
  • [40] PHYSIOLOGY OF THE COCHLEAR NERVE AND COCHLEAR NUCLEUS
    PALMER, AR
    BRITISH MEDICAL BULLETIN, 1987, 43 (04) : 838 - 855