Determination of opiates in whole blood using microextraction by packed sorbent and gas chromatography-tandem mass spectrometry

被引:30
|
作者
Prata, Margarida [1 ]
Ribeiro, Andreia [1 ]
Figueirinha, David [1 ]
Rosado, Tiago [1 ,2 ]
Oppolzer, David [1 ]
Restolho, Jose [1 ,3 ]
Araujo, Andre R. T. S. [4 ,5 ,6 ]
Costa, Suzel [7 ]
Barroso, Mario [7 ]
Gallardo, Eugenia [1 ,2 ]
机构
[1] Univ Beira Interior, Fac Ciencias Saude, Ctr Invest Ciencias Saude, Ave Infante D Henrique, P-6201506 Covilha, Portugal
[2] Univ Beira Interior, Lab Farmaco, Toxicol, UBIMed,EM506, P-6200284 Covilha, Portugal
[3] Nal von Minden GmbH, Friedenstr 32, D-93053 Regensburg, Germany
[4] IPG, Escola Super Saude, Ave Rainha D Amelia S-N, P-6300749 Guarda, Portugal
[5] Inst Politecn Guarda UDI IPG, Unidade Invest Desenvolvimento Interior, Ave Rainha D Amelia S-N, P-6300749 Guarda, Portugal
[6] Univ Porto, Fac Farm, Dept Ciencias Quim, Lab Quim Aplicada LAQV Requimte, Rua Jorge Viterbo de Ferreira 228, P-4050313 Porto, Portugal
[7] Inst Nacl Med Legal & Ciencias Forenses Delegacao, Serv Quim & Toxicol Forenses, Rua Manuel Bento de Sousa 3, P-1169207 Lisbon, Portugal
关键词
Opiates; Microextraction by packed sorbent; GC-MS/MS; Blood; LIQUID-PHASE MICROEXTRACTION; HUMAN PLASMA; PSYCHOACTIVE SUBSTANCES; OPIUM-ALKALOIDS; PERFORMANCE; EXTRACTION; DRUGS; MORPHINE; URINE; ABUSE;
D O I
10.1016/j.chroma.2019.05.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In Portugal, and worldwide, the abuse of psychoactive substances is increasing, with a significant incidence of deaths related to their consumption. Opiates are one of the most prevalent group of substances in that context, and they are responsible for a significant impact of the mentioned harms. Therefore, it becomes necessary to equip labs with faster and effective methods to identify and quantify these substances. This work describes the development and validation of a novel analytical method for the simultaneous determination of morphine, codeine and 6-monoacetylmorphine in blood samples by gas chromatography-tandem mass spectrometry (GC-MS/MS), using microextraction by packed sorbent (MEPS) for sample preparation. Before the MEPS procedure, a precipitation step with acetonitrile was performed. The MEPS parameters were optimized using the fractional factorial planning (2k-1) and surface response methodology. The final optimized conditions were: number of strokes (20), amount of formic acid in the washing solution (3.36%), number of washes of the sorbent (1), amount of ammonium hydroxide in the elution solution (2.36%) and number of elution cycles (11). After the extraction procedure, the analytes were derivatized with MSTFA with 5% TMS. Using a sample volume of 250 mu L, the method was validated according to internationally accepted standards. The method proved to be linear in the range of 5-1000 ng/mL with coefficients of determination greater than 0.99 for all analytes. Intra- and inter-day precision and accuracy were in accordance with the above-mentioned criteria, presenting coefficients of variation <= 15% and relative errors within a range of +/- 15% of the theoretical concentration. The absolute recoveries ranged from 6 to 23%. The validated method was applied to the analysis of real samples, being an advantageous tool for the detection of those substances in blood. This is the first time that GC-MS/MS with MEPS was used for the determination of these compounds in biological fluids. (C) 2019 Published by Elsevier B.V.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [41] Determination of Pesticides in Wheat Flour Using Microextraction on Packed Sorbent Coupled to Ultra-High Performance Liquid Chromatography and Tandem Mass Spectrometry
    Francesca Di Ottavio
    Flavio Della Pelle
    Camilla Montesano
    Rossana Scarpone
    Alberto Escarpa
    Dario Compagnone
    Manuel Sergi
    Food Analytical Methods, 2017, 10 : 1699 - 1708
  • [42] Simple and rapid determination of phthalates using microextraction by packed sorbent and gas chromatography with mass spectrometry quantification in cold drink and cosmetic samples
    Kaur, Ramandeep
    Heena
    Kaur, Ripneel
    Rani, Susheela
    Malik, Ashok Kumar
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (05) : 923 - 931
  • [43] Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography-Mass Spectrometry
    Garcia-Garcia, Samuel
    Matilla-Gonzalez, Hector
    Pena, Javier
    del Nogal Sanchez, Miguel
    Maria Casas-Ferreira, Ana
    Perez Pavon, Jose Luis
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (20)
  • [44] A Fast and Simple Procedure for Polybrominated Diphenyl Ether Determination in Egg Samples by Using Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry
    Marilia Cristina Oliveira Souza
    Bruno Alves Rocha
    Juliana Maria Oliveira Souza
    Andresa Aparecida Berretta
    Fernando Barbosa
    Food Analytical Methods, 2019, 12 : 1528 - 1535
  • [45] Determination of polycyclic aromatic hydrocarbons in water samples using online microextraction by packed sorbent coupled with gas chromatography-mass spectrometry
    Fu, Shuai
    Fan, Jun
    Hashi, Yuki
    Chen, Zilin
    TALANTA, 2012, 94 : 152 - 157
  • [46] Determination of endogenous anabolic steroids in hair using gas chromatography-tandem mass spectrometry
    Shen Min
    Xiang Ping
    Shen Baohua
    Wang Mengye
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (04) : 454 - 459
  • [47] Determination of chlorpyrifos and its metabolite in vegetables using gas chromatography-tandem mass spectrometry
    Ling Yun
    Wang Han
    Yong Wei
    Chu Xiaogang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (01) : 78 - 81
  • [48] Determination of Emerging Contaminants in Cereals by Gas Chromatography-Tandem Mass Spectrometry
    Albero, Beatriz
    Luis Tadeo, Jose
    Ana Perez, Rosa
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [49] Multiresidue determination of pesticides in tea by gas chromatography-tandem mass spectrometry
    Saito-Shida, Shizuka
    Nemoto, Satoru
    Teshima, Reiko
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2015, 50 (11) : 760 - 776
  • [50] Determination of Mycotoxins in Bee Pollen by Gas Chromatography-Tandem Mass Spectrometry
    Rodriguez-Carrasco, Yelko
    Font, Guillermina
    Manes, Jordi
    Berrada, Houda
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (08) : 1999 - 2005