Quantitative Computed Tomography Liver Perfusion Imaging Using Dynamic Spiral Scanning With Variable Pitch Feasibility and Initial Results in Patients With Cancer Metastases

被引:62
|
作者
Goetti, Robert [2 ]
Leschka, Sebastian [2 ]
Desbiolles, Lotus [2 ]
Klotz, Ernst [3 ]
Samaras, Panagiotis [4 ]
von Boehmer, Lotta [4 ]
Stenner, Frank [4 ]
Reiner, Caecilia [2 ]
Stolzmann, Paul [2 ]
Scheffel, Hans [2 ]
Knuth, Alexander [4 ]
Marincek, Borut [2 ]
Alkadhi, Hatem [1 ,2 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[3] Siemens Healthcare, Forchheim, Germany
[4] Univ Zurich Hosp, Div Oncol, CH-8091 Zurich, Switzerland
关键词
liver; perfusion; computed tomography; metastasis; COLORECTAL-CANCER; HEPATIC PERFUSION; TUMOR VASCULARITY; CT; MDCT; REPRODUCIBILITY; IMAGES;
D O I
10.1097/RLI.0b013e3181e1937b
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility and image quality of computed tomography (CT) liver perfusion imaging using an adaptive 4D spiral-mode, developed to extend the z-axis coverage, and to report initial qualitative and quantitative results in patients with cancer metastases. Materials and Methods: A total of 21 patients with liver metastases of various origins underwent CT perfusion imaging (100 kV and 150 mAs/rot) using a 4D spiral-mode with single-source 64-slice CT (n = 7) with a scan range of 6.7cm (protocol A: 16 cycles, 46.5 seconds examination time), or dual-source 128-slice CT with a scan range of 14.8 cm (protocol B: 16 cycles, 46.5 seconds examination time, n = 7; protocol C: 12 cycles, 51.0 seconds examination time, n = 7). Ability to suspend respiration during perfusion imaging was monitored. Two independent readers assessed image quality on a 4-point scale, both before and after motion correction, and performed a qualitative (ie, arterial enhancement pattern and enhancement change over time) and quantitative perfusion (ie, arterial liver perfusion [ALP]; portal-venous perfusion [PVP]; hepatic perfusion index [HPI]) analysis. Results: Of 21 patients, 7 (33%) could suspend respiration throughout the perfusion study and 14 (67%) resumed shallow breathing during the perfusion scan. The 21 patients had a total of 88 metastases. The scan range of protocol A covered at least 1 metastasis in all patients (total 20/34 [58.8%] metastases). The scan range of protocol B and C covered 53 of 54 (98.1%) metastases, whereas one metastasis in segment VIII was only partially imaged. Image quality was diagnostic both before and after motion correction, whereas being significantly better after motion correction (P < 0.001). Qualitative perfusion analysis of 67 metastases revealed diffuse arterial enhancement in 3 (4.5%), sparse enhancement in 11 (16.4%), peripheral-nodular enhancement in 9 (13.4%), rim-like enhancement in 15 (22.4%), and none in 29 (43.3%) metastases. Enhancement over time of 67 metastases showed a centripetal progression in 6 (8.9%), sustained portal phase in 16 (23.9%), wash-out in 16 (23.9%), and none in 29 (43.3%) metastases. Quantitative perfusion analysis revealed significantly higher arterial liver perfusion and HPI in metastases and metastasis borders than in adjacent normal liver tissue (P < 0.001 each). Portal-venous perfusion was significantly lower in metastases and metastasis borders than in normal liver tissue (P < 0.001). There were no significant differences in image quality and qualitative perfusion analysis between the 3 protocols (P = n.s.). Calculated effective radiation doses were 13.4 mSv for protocol A, 30.7 mSv for protocol B, and 23.0 mSv for protocol C. Conclusion: CT perfusion imaging of the liver using the 4D spiral-mode is feasible with diagnostic image quality, and enables the reliable qualitative and quantitative analysis of the normal and metastatic liver parenchyma. Radiation dose issues must be considered when determining the scan range, number of cycles, and scan duration of the perfusion CT protocol.
引用
收藏
页码:419 / 426
页数:8
相关论文
共 36 条
  • [21] Quantitative colorectal cancer perfusion measurement using dynamic contrast-enhanced multidetector-row computed tomography - Effect of acquisition time and implications for protocols
    Goh, V
    Halligan, S
    Hugill, JA
    Gartner, L
    Bartram, CI
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (01) : 59 - 63
  • [22] Evaluating cerebral hemodynamics using quantitative digital subtraction angiography and flat-detector computed tomography perfusion imaging: A comparative study in patients with carotid stenosis
    Chen, Liang-Wei
    Lin, Chung-Jung
    Guo, Wan-Yuo
    Hung, Sheng-Che
    Lee, Han-Jui
    Chen, Ko-Kung
    Chang, Feng-Chi
    Luo, Chao-Bao
    Chu, Wei-Fa
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2018, 81 (11) : 977 - 984
  • [23] Quantitative Analysis of Vertebral Bone Marrow Perfusion Using Dynamic Contrast-Enhanced MRI: Initial Results in Osteoporotic Patients With Acute Vertebral Fracture
    Biffar, Andreas
    Schmidt, Gerwin P.
    Sourbron, Steven
    D'Anastasi, Melvin
    Dietrich, Olaf
    Notohamiprodjo, Mike
    Reiser, Maximilian F.
    Baur-Melnyk, Andrea
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (03) : 676 - 683
  • [24] COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY WITH A CONSISTENT DOSE BELOW 2 MSV USING DOUBLE PROSPECTIVELY ECG-TRIGGERED HIGH-PITCH SPIRAL ACQUISITION IN PATIENTS WITH ATRIAL FIBRILLATION: INITIAL EXPERIENCE
    Wang Qi
    Chen Yundai
    HEART, 2013, 99 : E268 - E268
  • [25] Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experience
    Qi Wang
    Jing Qin
    Bai He
    Yin Zhou
    Jun-jie Yang
    Xiao-ling Hou
    Xiao-bo Yang
    Jiu-hong Chen
    Yun-dai Chen
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1341 - 1349
  • [26] Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experience
    Wang, Qi
    Qin, Jing
    He, Bai
    Zhou, Yin
    Yang, Jun-jie
    Hou, Xiao-ling
    Yang, Xiao-bo
    Chen, Jiu-hong
    Chen, Yun-dai
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1341 - 1349
  • [27] Voxelwise comparison of perfusion parameters estimated using dynamic contrast enhanced (DCE) computed tomography and DCE-magnetic resonance imaging in locally advanced cervical cancer
    Kallehauge, Jesper
    Nielsen, Thomas
    Haack, Soren
    Peters, David Alberg
    Mohamed, Sandy
    Fokdal, Lars
    Lindegaard, Jacob C.
    Hansen, David C.
    Rasmussen, Finn
    Tanderup, Kari
    Pedersen, Erik Morre
    ACTA ONCOLOGICA, 2013, 52 (07) : 1360 - 1368
  • [28] Quantitatively assessed dynamic contrast-enhanced magnetic resonance imaging in patients with chronic obstructive pulmonary disease: Correlation of perfusion parameters with pulmonary function test and quantitative computed tomography
    Jang, Yu Mi
    Oh, Yeon-Mok
    Seo, Joon Beom
    Kim, Namkug
    Chae, Eun Jin
    Lee, Young Kyung
    Lee, Sang Do
    INVESTIGATIVE RADIOLOGY, 2008, 43 (06) : 403 - 410
  • [29] Three-dimensional High Dose Rate Intracavitary Image-guided Brachytherapy for the Treatment of Cervical Cancer Using a Hybrid Magnetic Resonance Imaging/Computed Tomography Approach: Feasibility and Early Results
    Beriwal, S.
    Kannan, N.
    Kim, H.
    Houser, C.
    Mogus, R.
    Sukumvanich, R.
    Olawaiye, A.
    Richard, S.
    Kelley, J. L.
    Edwards, R. P.
    Krivak, T. C.
    CLINICAL ONCOLOGY, 2011, 23 (10) : 685 - 690
  • [30] Can Whole-body Magnetic Resonance Imaging with Diffusion-weighted Imaging Replace Tc 99m Bone Scanning and Computed Tomography for Single-step Detection of Metastases in Patients with High-risk Prostate Cancer?
    Lecouvet, Frederic E.
    El Mouedden, Jawad
    Collette, Laurence
    Coche, Emmanuel
    Danse, Etienne
    Jamar, Francois
    Machiels, Jean-Pascal
    Vande Berg, Bruno
    Omoumi, Patrick
    Tombal, Bertrand
    EUROPEAN UROLOGY, 2012, 62 (01) : 68 - 75