Quantitative Computed Tomography Liver Perfusion Imaging Using Dynamic Spiral Scanning With Variable Pitch Feasibility and Initial Results in Patients With Cancer Metastases

被引:62
|
作者
Goetti, Robert [2 ]
Leschka, Sebastian [2 ]
Desbiolles, Lotus [2 ]
Klotz, Ernst [3 ]
Samaras, Panagiotis [4 ]
von Boehmer, Lotta [4 ]
Stenner, Frank [4 ]
Reiner, Caecilia [2 ]
Stolzmann, Paul [2 ]
Scheffel, Hans [2 ]
Knuth, Alexander [4 ]
Marincek, Borut [2 ]
Alkadhi, Hatem [1 ,2 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[3] Siemens Healthcare, Forchheim, Germany
[4] Univ Zurich Hosp, Div Oncol, CH-8091 Zurich, Switzerland
关键词
liver; perfusion; computed tomography; metastasis; COLORECTAL-CANCER; HEPATIC PERFUSION; TUMOR VASCULARITY; CT; MDCT; REPRODUCIBILITY; IMAGES;
D O I
10.1097/RLI.0b013e3181e1937b
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility and image quality of computed tomography (CT) liver perfusion imaging using an adaptive 4D spiral-mode, developed to extend the z-axis coverage, and to report initial qualitative and quantitative results in patients with cancer metastases. Materials and Methods: A total of 21 patients with liver metastases of various origins underwent CT perfusion imaging (100 kV and 150 mAs/rot) using a 4D spiral-mode with single-source 64-slice CT (n = 7) with a scan range of 6.7cm (protocol A: 16 cycles, 46.5 seconds examination time), or dual-source 128-slice CT with a scan range of 14.8 cm (protocol B: 16 cycles, 46.5 seconds examination time, n = 7; protocol C: 12 cycles, 51.0 seconds examination time, n = 7). Ability to suspend respiration during perfusion imaging was monitored. Two independent readers assessed image quality on a 4-point scale, both before and after motion correction, and performed a qualitative (ie, arterial enhancement pattern and enhancement change over time) and quantitative perfusion (ie, arterial liver perfusion [ALP]; portal-venous perfusion [PVP]; hepatic perfusion index [HPI]) analysis. Results: Of 21 patients, 7 (33%) could suspend respiration throughout the perfusion study and 14 (67%) resumed shallow breathing during the perfusion scan. The 21 patients had a total of 88 metastases. The scan range of protocol A covered at least 1 metastasis in all patients (total 20/34 [58.8%] metastases). The scan range of protocol B and C covered 53 of 54 (98.1%) metastases, whereas one metastasis in segment VIII was only partially imaged. Image quality was diagnostic both before and after motion correction, whereas being significantly better after motion correction (P < 0.001). Qualitative perfusion analysis of 67 metastases revealed diffuse arterial enhancement in 3 (4.5%), sparse enhancement in 11 (16.4%), peripheral-nodular enhancement in 9 (13.4%), rim-like enhancement in 15 (22.4%), and none in 29 (43.3%) metastases. Enhancement over time of 67 metastases showed a centripetal progression in 6 (8.9%), sustained portal phase in 16 (23.9%), wash-out in 16 (23.9%), and none in 29 (43.3%) metastases. Quantitative perfusion analysis revealed significantly higher arterial liver perfusion and HPI in metastases and metastasis borders than in adjacent normal liver tissue (P < 0.001 each). Portal-venous perfusion was significantly lower in metastases and metastasis borders than in normal liver tissue (P < 0.001). There were no significant differences in image quality and qualitative perfusion analysis between the 3 protocols (P = n.s.). Calculated effective radiation doses were 13.4 mSv for protocol A, 30.7 mSv for protocol B, and 23.0 mSv for protocol C. Conclusion: CT perfusion imaging of the liver using the 4D spiral-mode is feasible with diagnostic image quality, and enables the reliable qualitative and quantitative analysis of the normal and metastatic liver parenchyma. Radiation dose issues must be considered when determining the scan range, number of cycles, and scan duration of the perfusion CT protocol.
引用
收藏
页码:419 / 426
页数:8
相关论文
共 36 条
  • [1] Performance Assessment of Dynamic Spiral Scan Modes With Variable Pitch for Quantitative Perfusion Computed Tomography
    Haberland, Ulrike
    Klotz, Ernst
    Abolmaali, Nasreddin
    INVESTIGATIVE RADIOLOGY, 2010, 45 (07) : 378 - 386
  • [2] Study on 64-layer Spiral Computed Tomography Perfusion Imaging in Patients with Fatty Liver
    Rao Xiao-hui
    Su Qi
    Cai Lei
    Qin Jia-sheng
    Cai Li-quan
    Hong He
    Wang Kang-hua
    Ai Zhi-guo
    Zhang Sheng
    JOURNAL OF INTERNATIONAL TRANSLATIONAL MEDICINE, 2014, 2 (04): : 453 - 456
  • [3] FUNCTIONAL IMAGING OF CHANGES IN HUMAN INTRARENAL PERFUSION USING QUANTITATIVE DYNAMIC COMPUTED-TOMOGRAPHY
    MILES, KA
    HAYBALL, MP
    DIXON, AK
    INVESTIGATIVE RADIOLOGY, 1994, 29 (10) : 911 - 914
  • [4] PERFUSION COMPUTED TOMOGRAPHY AS PROGNOSTIC AND PREDICTIVE FACTOR IN PATIENTS WITH COLORECTAL CANCER LIVER METASTASES TREATED WITH BEVACIZUMAB
    De Sanctis, R.
    Quadrini, S.
    Longo, F.
    Del Signore, E.
    Gori, B.
    Stumbo, L.
    Adua, D.
    Sollazzo, P.
    Manganaro, L.
    Di Seri, M.
    ANNALS OF ONCOLOGY, 2010, 21 : 198 - 199
  • [5] Clinical Study of Tumor Angiogenesis and Perfusion Imaging Using Multi-slice Spiral Computed Tomography for Breast Cancer
    Xu, Na
    Lei, Zhen
    Li, Xiao-Long
    Zhang, Jun
    Li, Chen
    Feng, Guo-Quan
    Li, Di-Nuo
    Liu, Jing-Yi
    Wei, Qiang
    Bian, Ting-Ting
    Zou, Tian-Yu
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2013, 14 (01) : 429 - 433
  • [6] The Value of 320-Slice Spiral Computed Tomography Perfusion Imaging in Staging and Long-Term Dynamic Evaluation of Breast Cancer
    Geng, Hequn
    Zhang, Zhilin
    Zhang, Xiaochen
    Liang, Zhandong
    Li, Yong
    Cui, Shujun
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [7] Dynamic contrast-enhanced computed tomography in the treatment evaluation of patients with colorectal liver metastases treated with ablation: a feasibility study
    Andersen, Iben R.
    Thorup, Kennet
    Jepsen, Betina N.
    Mortensen, Frank, V
    Nielsen, Dennis T.
    Rasmussen, Finn
    ACTA RADIOLOGICA, 2019, 60 (08) : 936 - 945
  • [8] Multiphasic Dynamic Computed Tomography Evaluation of Liver Tissue Perfusion Characteristics Using the Dual Maximum Slope Model in Patients With Cirrhosis and Hepatocellular Carcinoma: A Feasibility Study
    Lee, Dong Ho
    Lee, Jeong Min
    Klotz, Ernst
    Han, Joon Koo
    INVESTIGATIVE RADIOLOGY, 2016, 51 (07) : 430 - 434
  • [9] Simultaneous Injection of Contrast and Saline Using Spiral Flow-Generating Tube for Hepatic Dynamic Computed Tomography: Effect on Enhancement of Liver Parenchyma and Metastases to the Liver
    Nagata, Hiroji
    Iori, Hisako
    Yoshida, Shiori
    Kawashima, Hiroki
    Nishino, Yuka
    Sakasai, Ryo
    Yamamura, Hiroshi
    Minami, Tetsuya
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (06) : 875 - 881
  • [10] Liver Metastases From Colorectal Cancer Treated With Conventional and Antiangiogenetic Chemotherapy: Evaluation With Liver Computed Tomography Perfusion and Magnetic Resonance Diffusion-Weighted Imaging
    Anzidei, Michele
    Napoli, Alessandro
    Zaccagna, Fulvio
    Cartocci, Gaia
    Saba, Luca
    Menichini, Guendalina
    Marincola, Beatrice Cavallo
    Marotta, Eugenio
    Di Mare, Luisa
    Catalano, Carlo
    Passariello, Roberto
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (06) : 690 - 696