Non-invasive blood glucose measurement using multiple laser diodes

被引:4
|
作者
Ooi, E. T. [1 ]
Zhang, X. Q. [1 ]
Chen, J. H. [1 ]
Soh, P. H. [1 ]
Ng, K. [1 ]
Yeo, J. H. [1 ]
机构
[1] Innovat Ctr, GlucoSTATS Syst, Blk 2 Unit 223 18 Nanyang Drive, Nanyang, Singapore
来源
关键词
non-invasive blood glucose measurement; laser diodes; near infrared (NIR); diabetes; diffuse reflectance;
D O I
10.1117/12.698881
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the event of diabetes clinicians have advocated that frequent monitoring of a diabetic's blood glucose level is the key to avoid future complications (kidney failure, blindness, amputations, premature death, etc.,) associated with the disease. While the test-strip glucose meters available in current consumer markets allow for frequent monitoring, a more convenient technique that is accurate, painless and sample-free is preferable in a diabetic's daily routine. This paper presents a non-invasive blood glucose measurement technique using diffuse reflectance near infrared (NIR) signals. This technique uses a set of laser diodes, each operating at fixed wavelengths in the first overtone region. The NIR signals from the laser diodes are channeled to the measurement site viz., the nail-bed by means of optical fibers. A series of in vivo experiments have been performed on eight normal human subjects using a standard Oral Glucose Tolerance Test (OGTT) protocol. The reflected NIR signals are inputs to a Partial Least Squares (PLS) algorithm for calibration and future predictions. The calibration models used are developed using in vivo datasets and are unique to a particular individual. The 1218 paired points collected from the eight test subjects plotted on the Clarke Error Grid, revealed that 87.3% of these points fall within the A zone while the remainder, within the B zone, both of which, are clinically accepted. The standard error of prediction was +/- 13.14mg/dL for the best calibration model. A Bland-Altman analysis of the 1218 paired points yields a 76.3% confidence level for a measurement accuracy of +/- 20mg/dL. These results demonstrate the initial potential of the technique for non-invasive blood glucose measurements in vivo.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Non-Invasive Blood Glucose Measurement Using Near Infra-Red Spectroscopy
    Priyoti, Anika Tabassum
    Jim, Salman Jubair
    Hossain, Sushmit
    Mahmud, Shafkat
    Salvin, Sujana
    Bhattacharjee, Arnab
    PROCEEDINGS OF 2019 IEEE R10 HUMANITARIAN TECHNOLOGY CONFERENCE (IEEE R10 HTC 2019), 2019, : 1 - 4
  • [22] Removing subject dependencies on Non-Invasive Blood Glucose Measurement using Hybrid Techniques
    Pathirage, Kasun D.
    Roopasinghe, Pubudu
    Sooriyaarachchi, Jinani J.
    Weththasinghe, Rasangika
    Nanayakkara, Nuwan D.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 7197 - 7200
  • [23] Non-invasive blood glucose measurement Application of near infrared optical measurement
    Anas, M. N.
    Syafirah, A.
    Norali, A. N.
    Normahira, M.
    2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT), 2012, : 258 - 261
  • [24] Systems for non-invasive Glucose Measurement
    Heinemann, Lutz
    Schlueter, Sandra
    Freckmann, Guido
    DIABETES STOFFWECHSEL UND HERZ, 2020, 29 (02): : 127 - 127
  • [25] Non-invasive Estimation of Blood Glucose
    Sidley, Matthew
    Venkataraman, Jayanti
    2013 IEEE APPLIED ELECTROMAGNETICS CONFERENCE (AEMC), 2013,
  • [26] Study on optical measurement conditions for non-invasive blood glucose sensing
    Xu, KX
    Chen, WL
    Jiang, JY
    Qiu, QJ
    COMPLEX DYNAMICS, FLUCTUATIONS, CHAOS, AND FRACTALS IN BIOMEDICAL PHOTONICS, 2004, 5 (19): : 83 - 91
  • [27] An Optimized Non-Invasive Blood Glucose and Temperature Body Measurement System
    Ibrahim, Hagar
    Darweesh, M. Saeed
    Soltan, Ahmed
    2022 11TH INTERNATIONAL CONFERENCE ON MODERN CIRCUITS AND SYSTEMS TECHNOLOGIES (MOCAST), 2022,
  • [28] An IoMT based Non-Invasive Precise Blood Glucose Measurement System
    Jain, Prateek
    Pancholi, Sidharth
    Joshi, Amit M.
    2019 IEEE INTERNATIONAL SYMPOSIUM ON SMART ELECTRONIC SYSTEMS (ISES 2019), 2019, : 111 - 116
  • [29] Sensor Calibration Models for a Non-Invasive Blood Glucose Measurement Sensor
    Stemmann, M.
    Stahl, F.
    Lallemand, J.
    Renard, E.
    Johansson, R.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4979 - 4982
  • [30] Non-invasive measurement of colonic blood flow distribution using laser Doppler imaging
    Hajivassiliou, CA
    Greer, K
    Fisher, A
    Finlay, IG
    BRITISH JOURNAL OF SURGERY, 1998, 85 (01) : 52 - 55