Fire load survey of historic buildings: A case study

被引:8
|
作者
Claret, Antonio M. [1 ]
Andrade, Adriana T. [1 ]
机构
[1] Univ Fed Ouro Preto, Fire Risk Anal Lab, Sch Mines, BR-35400000 Ouro Preto, MG, Brazil
关键词
historic buildings; fire load survey; fire load composition;
D O I
10.1177/1042391506064912
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The results of a fire load density survey carried out in Onto Preto in the state of Minas Gerais, Brazil are presented. The inventory method is used and details of the survey methodology and processing are given. Forty-three buildings are surveyed and the determination of fire load density is made for 39 occupancies, each occupancy comprising one or more rooms, or even an entire building. The average fire load density is 2989 MJ/m(2) and the standard deviation is 2833 MJ/m(2) Commercial stores are found to be the most heavily loaded but a single maximum fire load density of 14,560 MJ/m(2) is found in a drugstore. Because of new extensions of old buildings, some rooms have relatively low fire loads. It is observed that wood contributes a substantial portion of fire load, being 35% of movable fire load and 37% of fixed fire load. Comparison of the results, with those established by Brazilian standard NBR 14432, indicate that measured values could exceed standard values by up to a factor of 10.
引用
下载
收藏
页码:103 / 112
页数:10
相关论文
共 50 条
  • [21] The historic American buildings survey and GPS
    Boucher, JE
    ON THE FRONTIERS OF CONSERVATION: PROCEEDINGS OF THE TENTH CONFERENCE ON RESEARCH AND RESOURCE MANAGEMENT IN PARKS AND ON PUBLIC LANDS, 1999, : 455 - 460
  • [22] Seismic Retrofitting of Historic Masonry Buildings - Case Study
    Santhakumar, A. R.
    Mathews, M. S.
    Thirumurugan, S.
    Uma, Rao
    7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTIONS: STRENGTHENING AND RETROFITTING, PTS 1 AND 2, 2010, 133-134 : 991 - 996
  • [23] Fire load: Survey data, recent standards, and probabilistic models for office buildings
    Khorasani, Negar Elhami
    Garlock, Maria
    Gardoni, Paolo
    ENGINEERING STRUCTURES, 2014, 58 : 152 - 165
  • [24] Movable fire load survey for old residential highrise buildings in Hong Kong
    Chow, W. K.
    Ngan, S. Y.
    Lui, G. C. H.
    Safety and Security Engineering II, 2007, 94 : 215 - 222
  • [25] FROM SITE SURVEY TO HBIM MODEL FOR THE DOCUMENTATION OF HISTORIC BUILDINGS: THE CASE STUDY OF HEXINWU VILLAGE IN CHINA
    Lin, Guiye
    Giordano, Andrea
    Sang, Kun
    CONSERVATION SCIENCE IN CULTURAL HERITAGE, 2020, 20 : 111 - 123
  • [26] Stone decay induced by fire on historic buildings:: the case of the cloister of Lisbon Cathedral (Portugal)
    Dionisio, A.
    BUILDING STONE DECAY: FROM DIAGNOSIS TO CONSERVATION, 2007, 271 : 87 - 98
  • [27] Practical Challenges in Mitigating the Aftermath of Fire in Historic Buildings
    Kincaid, Simon
    HISTORIC ENVIRONMENT-POLICY & PRACTICE, 2021, 12 (01): : 77 - 96
  • [28] Fire prevention in historic buildings - approaches for safe practice
    Kincaid, Simon
    HISTORIC ENVIRONMENT-POLICY & PRACTICE, 2022, 13 (03): : 361 - 380
  • [29] Fire Risk Analysis: A Proposal for Historic Buildings in Brazil
    Ferreira Minervino, Bernardete de Lourdes
    Calmeiro, Cristina C.
    Von Kruguer, Paulo Gustavo
    Rodrigues, Joao Paulo C.
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024,
  • [30] Fire resistance of historic iron structures in multistorey buildings
    Nieuwmeijer, G.G.
    WIT Transactions on the Built Environment, 2001, 55 : 39 - 48