Purpose of review The purpose of this review is to highlight recent research findings in contact force-sensing radiofrequency ablation catheters. Recent findings Contact force parameters evaluated during pulmonary vein isolation for treating atrial fibrillation correlated well with the presence of gaps in the wide area circumferential ablation lines at 3 months, decreased procedural times, and improved clinical outcome at 1 year. The contact force during pulmonary vein isolation should be a target of 10-20 g of force and a minimum force-time integral of 400 g/s for each new lesion. In the ventricle, contact force varied depending on whether a transseptal versus retrograde aortic approach was utilized: contact force use yielded more visible ablation lesions at necropsy. Summary Contact force-sensing catheters have demonstrated improved outcome after catheter ablation of atrial fibrillation. Future studies will focus on ventricular tachycardia ablation; preliminary data suggest more durable lesions with contact force-sensing catheters. Contact force catheters may enhance academic training by giving real-time feedback regarding catheter contact, increase safety, and may lead to a resurgence in remote navigation ablation systems.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [21] Reproducibility of Paroxysmal Atrial Fibrillation Ablation Clinical Outcomes Using Composite Ablation Index With Different Contact Force-Sensing Catheters
    Di Biase, Luigi
    Tabereaux, Paul
    Liu, Christopher F.
    Vasaiwala, Smit
    Chugh, Aman
    Saliba, Walid I.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (12):
  • [22] Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters
    Benali, Karim
    Lai, Van Duc
    Hammache, Nefissa
    Magnin-Poull, Isabelle
    de Chillou, Christian
    Sellal, Jean-Marc
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (04) : 931 - 940
  • [23] Clinical benefit of contact force-sensing catheters in the ablation of atrial fibrillation: Meta-analysis to dig for truth or bias? Reply
    Afzal, Muhammad R.
    Samanta, Anweshan
    Reddy, Madhu
    Lakkireddy, Dhanunjaya
    HEART RHYTHM, 2016, 13 (01) : E1 - E2
  • [24] Contact Force-Sensing versus Standard Catheters in Non-Fluoroscopic Radiofrequency Catheter Ablation of Idiopathic Outflow Tract Ventricular Arrhythmias
    Karkowski, Grzegorz
    Kuniewicz, Marcin
    Zabek, Andrzej
    Kozluk, Edward
    Debski, Maciej
    Matusik, Pawel T.
    Lelakowski, Jacek
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [25] Force-sensing microsurgical needle holder
    Durand, Sebastien
    Nogueira, Antoine
    Lattion, Justine
    MICROSURGERY, 2022, 42 (02) : 201 - 202
  • [26] Force-sensing in Piezo ion channels
    Haselwandter, Christoph
    BIOPHYSICAL JOURNAL, 2023, 122 (03) : 159A - 160A
  • [27] Force-Sensing Sleeve for Laparoscopic Surgery
    Wee, Justin
    Brooks, Robert J.
    Looi, Thomas
    Azzie, Georges
    Drake, James
    Gerstle, J. Ted
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (03):
  • [28] Pulsed Field Ablation Using Focal Contact Force-Sensing Catheters for Treatment of Atrial Fibrillation: 1-Year Outcomes of the ECLIPSE AF Study
    Anic, Ante
    Phlips, Thomas
    Breskovic, Toni
    Mediratta, Vikramaditya
    Girouard, Steven
    Jurisic, Zrinka
    Sikiric, Ivan
    Lisica, Lucija
    Koopman, Pieter
    Antole, Nathalie
    Vijgen, Johan
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2025, 18 (01):
  • [29] Initial Experience with a Novel Flexible-Tip Contact Force-Sensing Catheter in the US
    Lo, Monica
    Loguidice, Michael
    Wenzel, Emily
    Friedman, Daniel
    Hattoum, Alexander
    Venkataraman, Rajesh
    Mathew, Dilip
    Nilsson, Kent
    Thambidorai, Senthil
    Burns, Meghan
    Gaeta, Lauren
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) : 1287 - 1287
  • [30] Pulsed field ablation using focal contact force-sensing catheters for treatment of atrial fibrillation: acute and 90-day invasive remapping results
    Anic, Ante
    Phlips, Thomas
    Breskovic, Toni
    Koopman, Pieter
    Girouard, Steven
    Mediratta, Vikramaditya
    Jurisic, Zrinka
    Sikiric, Ivan
    Lisica, Lucija
    Vijgen, Johan
    EUROPACE, 2023, 25 (06):