Contact force-sensing catheters

被引:15
|
作者
Hoffmayer, Kurt S. [1 ]
Gerstenfeld, Edward P. [2 ]
机构
[1] Univ Wisconsin, Sect Cardiac Electrophysiol, Div Cardiol, Madison, WI USA
[2] Univ Calif San Francisco, Sect Cardiac Electrophysiol, Div Cardiol, San Francisco, CA 94143 USA
关键词
atrial fibrillation; catheter ablation; contact force-sensing catheters; ventricular tachycardia; ELECTRODE-TISSUE CONTACT; PULMONARY VEIN ISOLATION; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; LESION SIZE; IMPEDANCE; RECONNECTION; TECHNOLOGIES; AMPLITUDE;
D O I
10.1097/HCO.0000000000000131
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose of review The purpose of this review is to highlight recent research findings in contact force-sensing radiofrequency ablation catheters. Recent findings Contact force parameters evaluated during pulmonary vein isolation for treating atrial fibrillation correlated well with the presence of gaps in the wide area circumferential ablation lines at 3 months, decreased procedural times, and improved clinical outcome at 1 year. The contact force during pulmonary vein isolation should be a target of 10-20 g of force and a minimum force-time integral of 400 g/s for each new lesion. In the ventricle, contact force varied depending on whether a transseptal versus retrograde aortic approach was utilized: contact force use yielded more visible ablation lesions at necropsy. Summary Contact force-sensing catheters have demonstrated improved outcome after catheter ablation of atrial fibrillation. Future studies will focus on ventricular tachycardia ablation; preliminary data suggest more durable lesions with contact force-sensing catheters. Contact force catheters may enhance academic training by giving real-time feedback regarding catheter contact, increase safety, and may lead to a resurgence in remote navigation ablation systems.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [1] Risk of atrioesophageal fistula formation with contact force-sensing catheters
    Black-Maier, Eric
    Pokorney, Sean D.
    Barnett, Adam S.
    Zeitler, Emily P.
    Sun, Albert Y.
    Jackson, Kevin P.
    Bahnson, Tristram D.
    Daubert, James P.
    Piccini, Jonathan P.
    HEART RHYTHM, 2017, 14 (09) : 1328 - 1333
  • [2] Validation of the accuracy of contact force measurement by contemporary force-sensing ablation catheters
    Kueffer, Thomas
    Haeberlin, Andreas
    Knecht, Sven
    Baldinger, Samuel H.
    Madaffari, Antonio
    Seiler, Jens
    Muehl, Aline
    Tanner, Hildegard
    Roten, Laurent
    Reichlin, Tobias
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (02) : 292 - 299
  • [3] Contact Force-Sensing Catheters Evolution or Revolution in Catheter Ablation Technology?
    Gerstenfeld, Edward P.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (01): : 5 - 6
  • [4] Contact force-sensing catheters: performance in an ex vivo porcine heart model
    Franco, Eduardo
    Rodriguez Munoz, Daniel
    Matia, Roberto
    Hernandez-Madrid, Antonio
    Sanchez Perez, Inmaculada
    Luis Zamorano, Jose
    Moreno, Javier
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (02) : 141 - 150
  • [5] Comparing rates of atrioesophageal fistula with contact force-sensing and non-contact force-sensing catheters: analysis of post-market safety surveillance data
    Hugh Calkins
    Andrea Natale
    Tara Gomez
    Alex Etlin
    Moe Bishara
    Journal of Interventional Cardiac Electrophysiology, 2020, 59 : 49 - 55
  • [6] Comparison of the accuracy of contact force measurement in four commercially available force-sensing ablation catheters
    Kueffer, T.
    Haeberlin, A.
    Knecht, S.
    Baldinger, S. H.
    Servatius, H.
    Madaffari, A.
    Seiler, J.
    Muhl, A.
    Franzeck, F.
    Asatryan, B.
    Noti, F.
    Tanner, H.
    Roten, L.
    Reichlin, T.
    SWISS MEDICAL WEEKLY, 2022, 152 : 16S - 16S
  • [7] Contact force-sensing catheters: performance in an ex vivo porcine heart model
    Eduardo Franco
    Daniel Rodríguez Muñoz
    Roberto Matía
    Antonio Hernández-Madrid
    Inmaculada Sánchez Pérez
    José Luis Zamorano
    Javier Moreno
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 141 - 150
  • [8] Comparing rates of atrioesophageal fistula with contact force-sensing and non-contact force-sensing catheters: analysis of post-market safety surveillance data
    Calkins, Hugh
    Natale, Andrea
    Gomez, Tara
    Etlin, Alex
    Bishara, Moe
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 59 (01) : 49 - 55
  • [9] Impact of Contact Force-Sensing Catheters on Fluoroscopy Time in Interventional Electrophysiology: A European Survey
    Fiedler, Lukas
    Blessberger, Hermann
    Balsam, Pawel
    De Potter, Tom
    Buchta, Piotr
    Ernst, Sabine
    Waldmann, Victor
    Costa, Francisco Moscoso
    Bogdan, Stefan
    Nahler, Alexander
    Hrncic, Denis
    Lambert, Thomas
    Schoenbauer, Robert
    Pfeffer, Michael
    Roithinger, Franz Xaver
    Steinwender, Clemens
    Kosiuk, Jedrzej
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [10] Monitoring Knee Contact Force with Force-Sensing Insoles
    Spencer, Alex
    Samaan, Michael
    Noehren, Brian
    SENSORS, 2023, 23 (10)