Within- and between-day loading response to ballet choreography

被引:3
|
作者
Nagy, Philip [1 ]
Brogden, Chris [1 ]
Orr, Gabrielle [2 ]
Greig, Matt [1 ]
机构
[1] Edge Hill Univ, Dept Sport & Phys Act, Sports Injuries Res Grp, Ormskirk, Lancs, England
[2] Edge Hill Univ, Dept Creat Arts, Ormskirk, Lancs, England
关键词
Accelerometry; ballet; fatigue; load; overuse; COMMITTEE CONSENSUS STATEMENT; INJURY RISK; LANDING BIOMECHANICS; SPORT; DANCERS; FATIGUE; ACCELEROMETRY; RELIABILITY; TOO;
D O I
10.1080/15438627.2021.1929223
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Overuse pathologies are prevalent in ballet injury. Ten amateur ballet dancers (age: 23.20 +/- 3.08 years) completed a progressive 5-stage choreographed routine on two consecutive days. Tri-axial accelerometers positioned at C7 and the dominant and non-dominant lower-limb were used to calculate accumulated PlayerLoad(TM) (PLTOTAL) and uni-axial contributions of the anterior-posterior (PLAP), medial-lateral (PLML), and vertical (PLV) planes. PLTOTAL increased significantly (p = 0.001) as a function of exercise duration within-trial, however there was no significant change between trials (p = 0.18). PLTOTAL at C7 was significantly (p = 0.001) lower than both lower-limbs, with no bilateral asymmetry evident (p = 0.97). Planar contributions to PLTOTAL were significantly greater in PLV than PLAP and PLML (p = 0.001). PlayerLoad(TM) demonstrated within-trial sensitivity to the progressive routine, however no residual fatigue effect was observed between trials. The results of this study suggest that accelerometers have efficacy in athlete monitoring and injury screening protocols, however unit placement should be considered for practical interpretation.
引用
收藏
页码:616 / 627
页数:12
相关论文
共 50 条
  • [21] Within- and between-day variability of non-invasive cardiovascular and metabolic parameters at rest and during adrenergic stimulation
    Nurnberger, J
    Schafers, RF
    Wenzel, RR
    Philipp, T
    Michel, MC
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 1997, 356 (04) : 16 - 16
  • [22] COMPARISON OF BETWEEN-DAY AND WITHIN-DAY DLCO MEASUREMENT IN SHEEP
    MCNEIL, JS
    MUNDIE, TG
    PHILLIPS, YY
    LABORATORY ANIMAL SCIENCE, 1986, 36 (05): : 586 - 586
  • [23] AGING AND WITHIN- AND BETWEEN-DAY VARIABILITY ASSESSED USING 7-DAY/24-HOUR AMBULATORY BLOOD PRESSURE MONITORING
    Okajima, Kiyotaka
    Otsuka, Kuniaki
    Oinuma, Sachiko
    Sasaki, Junko
    Yamanaka, Takashi
    Cornelissen, Germaine
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2014, 62 (12) : 2440 - 2442
  • [24] CORRECT AND INCORRECT ESTIMATION OF WITHIN-DAY AND BETWEEN-DAY VARIATION
    BOOKBINDER, MJ
    PANOSIAN, KJ
    CLINICAL CHEMISTRY, 1986, 32 (09) : 1734 - 1737
  • [25] Within- and between-day variability in transcutaneous Doppler ultrasound measurements of superior mesenteric artery blood flow (SMABF) in the fasted state
    Stubbs, TA
    Macdonald, IA
    PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) : 181 - 187
  • [26] Evaluation of the within- and between-day intra-tester and inter-tester reliability of positioning subjects into neutral and lordotic sitting postures
    Korakakis, Vasileios
    O'Sullivan, Kieran
    Sotiralis, Yiannis
    Karanasios, Stefanos
    Sideris, Vasilis
    Sideris, Alexandros
    Sakellariou, Konstantinos
    Giakas, Giannis
    EUROPEAN JOURNAL OF PHYSIOTHERAPY, 2019, 21 (03) : 142 - 152
  • [27] Within-day and between-day repeatability of measurements with an electronic nose in patients with COPD
    Bofan, Maria
    Mores, Nadia
    Baron, Marco
    Dabrowska, Malgorzata
    Valente, Salvatore
    Schmid, Maurizio
    Trove, Andrea
    Conforto, Silvia
    Zini, Gina
    Cattani, Paola
    Fuso, Leonello
    Mautone, Antonella
    Mondino, Chiara
    Pagliari, Gabriella
    D'Alessio, Tommaso
    Montuschi, Paolo
    JOURNAL OF BREATH RESEARCH, 2013, 7 (01)
  • [28] Within-day and between-day Reproducibility of Baroreflex Sensitivity in Healthy Adult Males
    Reynolds, L. J.
    De Ste Croix, M.
    James, D. V. B.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2016, 37 (06) : 457 - 463
  • [29] Within- and between-day reliability of spinal stiffness measurements obtained using a computer controlled mechanical indenter in individuals with and without low back pain
    Wong, Arnold Y. L.
    Kawchuk, Greg
    Parent, Eric
    Prasad, Narasimha
    MANUAL THERAPY, 2013, 18 (05) : 395 - 402
  • [30] Within-day and between-day variability of blood pressure mesurement in healthy conscious dogs
    Rattez, E. P.
    Reynolds, B. S.
    Lamour, C. J. Layssol
    Segalen, M. M.
    Lefebvre, H. P.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2008, 22 (03) : 799 - 799