Stability analysis of sub-/super-synchronous oscillation based on closed-loop transfer function poles of D-PMSG wind power systems

被引:2
|
作者
Shen, Ruixin [1 ]
Yang, Songhao [1 ]
Hao, Zhiguo [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Elect Engn, Xian, Peoples R China
基金
中国博士后科学基金;
关键词
sub; super-synchronous oscillation; poles of the transfer function; direct-drive permanent magnet synchronous generator; impedance method;
D O I
10.1002/tee.23618
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, the sub-/super-synchronous oscillation (SSO) caused by grid integration of direct-drive permanent magnet synchronous generators (D-PMSG) has attracted wide attention. However, most of the existing stability analysis methods are either complex or cannot quantitatively analyze the influence of parameter changes on system stability. To address the problems, this paper proposes a novel stability analysis method for SSO in the D-PMSG integrated power system based on closed-loop transfer function poles. Firstly, the impedance modeling method was introduced to analyze the stability of the D-PMSG power system. Then, a stability criterion was proposed based on the poles of the closed-loop function. The proposed criterion is simple and has a clear physical background. The real part of the poles represents the damping while the imaginary part of the pole reflects the oscillation frequency. Finally, simulation results verify the accuracy and effectiveness of the proposed method. Moreover, its application in influence factors for quantitative analysis was also validated. (c) 2022 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
引用
收藏
页码:1267 / 1275
页数:9
相关论文
共 26 条
  • [21] Probability Assessment of Characteristics of Sub-Synchronous Oscillation in D-PMSG-Based Wind Power Generation System
    Tao, Shun
    Zhao, Lei
    Liao, Kunyu
    Liu, Yunbo
    IEEE ACCESS, 2019, 7 : 133159 - 133169
  • [22] Modeling and Suppression Method of Sub/Super-synchronous Oscillation of Grid-connected DFIG Wind Farms (Part I): Sequence Impedance Modeling and Analysis of DFIG Wind Turbines Considering Power Loop
    Li G.
    Wang W.
    Zhang X.
    He G.
    Liu C.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (07): : 2438 - 2448
  • [23] Analysis of Sub/Super-Synchronous Oscillation of Direct-Drive Offshore Wind Power Grid-Connected System via VSC-HVDC
    Zhang Z.
    Li Q.
    Yu H.
    Chen H.
    Sun H.
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2022, 56 (12): : 1572 - 1583
  • [24] Analysis on Disturbance Transfer Path and Damping Characteristics of Sub-synchronous Interaction Between D-PMSG-based Wind Farm and LCC-HVDC
    Gao, Benfeng
    Liu, Yi
    Li, Yunhong
    Zhao, Feng
    Shao, Bingbing
    Zhao, Shuqiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (05): : 1713 - 1728
  • [25] Event analysis and real-time validation of doubly fed induction generator-based wind energy system with grid reactive power exchange under sub-synchronous and super-synchronous modes
    Thomas, Tomson
    Asok, Prince
    ENGINEERING REPORTS, 2020, 2 (12)
  • [26] Small Signal Stability Analysis of a DFIG Based Wind Power System With Tuned Damping Controller Under Super/Sub-Synchronous Mode of Operation
    Mishra, Y.
    Mishra, S.
    Li, Fangxing
    Dong, Z. Y.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 2457 - +