Reproducibility of Perfusion Parameters of Optic Disc and Macula in Rhesus Monkeys by Optical Coherence Tomography Angiography

被引:19
|
作者
Li, Jing [1 ,2 ]
Yang, Yi-Quan [1 ,2 ]
Yang, Di-Ya [1 ]
Liu, Xiang-Xiang [1 ,2 ]
Sun, Yun-Xiao [1 ,2 ]
Wei, Shi-Fei [1 ,2 ]
Wang, Ning-Li [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
[2] Capital Med Univ, Beijing Inst Ophthalmol, Beijing Tongren Hosp, Beijing 100005, Peoples R China
基金
中国国家自然科学基金;
关键词
Flow Index; Macula; Optic Disc; Optical Coherence Tomography Angiography; OCT ANGIOGRAPHY; NEOVASCULARIZATION; DEGENERATION; GLAUCOMA;
D O I
10.4103/0366-6999.180532
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Optical coherence tomography (OCT) angiography is a novel technique by which we can detect the local perfusion of fundus directly. The aim of this study was to evaluate the reproducibility of optic disc and macular flow perfusion parameters in rhesus monkeys using OCT angiography. Methods: Eighteen healthy monkeys (18 eyes) were subjected to optic disc and macula flow index measurements via a high-speed and high-resolution spectral-domain OCT XR Avanti with a split-spectrum amplitude de-correlation angiography algorithm. Right eye was imaged 3 times during the first examination and once during each of the two following examinations. The intra-visit and inter-visit intraclass correlation coefficients (ICCs) were both determined. Results: The average flow indices of the four optic disc area layers were 0.171 +/- 0.009 (optic nerve head), 0.015 +/- 0.004 (vitreous), 0.052 +/- 0.009 (radial peripapillary capillary), and 0.167 +/- 0.011 (choroid). Average flow indices of the four macula area layers were 0.044 +/- 0.011 (superficial retina), 0.036 +/- 0.011 (deep retina), 0.016 +/- 0.009 (outer retina), and 0.155 +/- 0.013 (choroid). Intra-visit (ICC value: 0.821-0.954) and inter-visit (ICC value: 0.844-0.899) repeatability were both high. Conclusions: The study is about the reproducibility of optic disc and macular perfusion parameters as measured by OCT angiography in healthy rhesus monkeys. Flow index measurement reproducibility is high for both the optic disc and macula of normal monkey eyes. OCT angiography might be a useful technique to assess changes when examining monkeys with experimental ocular diseases.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 50 条
  • [1] Reproducibility of Perfusion Parameters of Optic Disc and Macula in Rhesus Monkeys by Optical Coherence Tomography Angiography
    Li Jing
    Yang Yi-Quan
    Yang Di-Ya
    Liu Xiang-Xiang
    Sun Yun-Xiao
    Wei Shi-Fei
    Wang Ning-Li
    [J]. 中华医学杂志(英文版), 2016, 129 (09) : 1087 - 1090
  • [2] Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
    Jia, Yali
    Wei, Eric
    Wang, Xiaogang
    Zhang, Xinbo
    Morrison, John C.
    Parikh, Mansi
    Lombardi, Lori H.
    Gattey, Devin M.
    Armour, Rebecca L.
    Edmunds, Beth
    Kraus, Martin F.
    Fujimoto, James G.
    Huang, David
    [J]. OPHTHALMOLOGY, 2014, 121 (07) : 1322 - 1332
  • [3] Evaluation of the Optic Disc and Macula in Healthy Children Using Optical Coherence Tomography Angiography
    Icel, Erel
    Yilmaz, Hayati
    Ucak, Turgay
    Tasli, Nurdan Gamze
    Ugurlu, Adem
    Karakurt, Yucel
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2020, 50 (04): : 228 - 233
  • [4] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Yip, Vivien C. H.
    Wong, Hon Tym
    Yong, Vernon K. Y.
    Lim, Boon Ang
    Hee, Owen K.
    Cheng, Jun
    Fu, Huazhu
    Lim, Chingwei
    Tay, Elton L. T.
    Loo-Valdez, Roselyn G.
    Teo, Hwei Yee
    Lim, Angela P. H.
    Yip, Leonard W. L.
    [J]. JOURNAL OF GLAUCOMA, 2019, 28 (01) : 80 - 87
  • [5] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Jain, Kanika
    Pegu, Julie
    Bhoot, Madhu
    Dubey, Suneeta
    [J]. JOURNAL OF GLAUCOMA, 2019, 28 (07) : E131 - E132
  • [6] The effect of low cerebrospinal fluid pressure on optic disc and macula perfusion in monkey model using optical coherence tomography angiography
    Wang, Ningli
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [7] Optical Coherence Tomography Angiography in Optic Disc Swelling
    Fard, Masoud Aghsaei
    Jalili, Jalil
    Sahraiyan, Alireza
    Khojasteh, Hassan
    Hejazi, Marjane
    Ritch, Robert
    Subramanian, Prem S.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 191 : 116 - 123
  • [8] Macula and optic disc vessel density analyses in systemic lupus erythematosus with optical coherence tomography angiography
    Comcali, Sebile
    Yilmaz, Pinar Topcu
    Cavdarli, Cemal
    Coskun, Cigdem
    Maras, Yuksel
    Aslar, Zeynep
    Alp, Mehmet Numan
    [J]. MEDICINE, 2023, 102 (43) : E35835
  • [9] Response: Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Yip, Vivien C. H.
    Wong, Hon Tym
    Yong, Vernon K. Y.
    Lim, Boon-Ang
    Hee, Owen K.
    Cheng, Jun
    Fu, Huazhu
    Lim, Ching-Wei
    Tay, Elton L. T.
    Loo-Valdez, Roselyn G.
    Teo, Hwei-Yee
    Lim, Angela P. H.
    Yip, Leonard W. L.
    [J]. JOURNAL OF GLAUCOMA, 2019, 28 (07) : E132 - E133
  • [10] The vascular densities of the macula and optic disc in normal eyes from children by optical coherence tomography angiography
    Zhang, Yichi
    Zhang, Bihong
    Fan, Min
    Gao, Xiang
    Wen, Xin
    Li, Zijing
    Zeng, Peng
    Tan, Weiping
    Lan, Yuqing
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (02) : 437 - 444