Optical Coherence Tomography Angiography in Optic Disc Swelling

被引:50
|
作者
Fard, Masoud Aghsaei [1 ]
Jalili, Jalil [2 ]
Sahraiyan, Alireza [1 ]
Khojasteh, Hassan [1 ]
Hejazi, Marjane [2 ]
Ritch, Robert [3 ]
Subramanian, Prem S. [4 ]
机构
[1] Univ Tehran Med Sci, Eye Res Ctr, Farabi Eye Hosp BB, Tehran, Iran
[2] Univ Tehran Med Sci, Med Phys & Biomed Engn Dept, Recearch Ctr Mol & Cellular Imaging, Bioopt Imaging Grp,Sch Med, Tehran, Iran
[3] New York Eye & Ear Infirm Mt Sinai, Einhom Clin Res Ctr, New York, NY USA
[4] Univ Colorado, Sch Med, Dept Ophthalmol, Aurora, CO USA
关键词
LASER SPECKLE FLOWGRAPHY; NERVE HEAD; FLUORESCEIN ANGIOGRAPHY; MULTIPLE-SCLEROSIS; NEUROPATHY; PAPILLEDEMA; NEURITIS; GLAUCOMA; EDEMA;
D O I
10.1016/j.ajo.2018.04.017
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare optical coherence tomography angiography (OCT-A) of peripapillary total vasculature and capillaries in patients with optic disc swelling. DESIGN: Cross-sectional study. METHODS: Twenty nine eyes with acute nonarteritic anterior ischemic optic neuropathy (NAION), 44 eyes with papilledema, 8 eyes with acute optic neuritis, and 48 eyes of normal subjects were imaged using OCT-A. Peripapillary total vasculature information was recorded using a commercial vessel density map. Customized image analysis with major vessel removal was also used to measure whole-image capillary density and peripapillary capillary density (PCD). RESULTS: Mixed models showed that the peripapillary total vasculature density values were significantly lower in NAION eyes, followed by papilledema eyes and control eyes, using commercial software (P < .0001 for all comparisons). The customized software also showed significantly lower PCD of NAION eyes compared with papilledema eyes (all P < .001), but did not show significant differences between papilledema and control subjects. Our software showed significantly lower whole image and PCD in eyes with optic neuritis than papilledema. There was no significant difference between NAION and optic neuritis using our software. The area under the receiver operating curves for discriminating NAION from papilledema eyes and optic neuritis from papilledema eyes was highest for whole-image capillary density (0.94 and 0.80, respectively) with our software, followed by peripapillary total vasculature (0.9 and 0.74, respectively) with commercial software. CONCLUSIONS: OCT-A is helpful to distinguish NAION and papillitis from papilledema. Whole-image capillary density had the greatest diagnostic accuracy for differentiating disc swelling. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:116 / 123
页数:8
相关论文
共 50 条
  • [1] Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
    Jia, Yali
    Wei, Eric
    Wang, Xiaogang
    Zhang, Xinbo
    Morrison, John C.
    Parikh, Mansi
    Lombardi, Lori H.
    Gattey, Devin M.
    Armour, Rebecca L.
    Edmunds, Beth
    Kraus, Martin F.
    Fujimoto, James G.
    Huang, David
    [J]. OPHTHALMOLOGY, 2014, 121 (07) : 1322 - 1332
  • [2] Optical coherence tomography angiography characteristics of optic disc melanocytoma
    Nan Zhou
    Xiaolin Xu
    Wenbin Wei
    [J]. BMC Ophthalmology, 20
  • [3] Optical coherence tomography angiography characteristics of optic disc melanocytoma
    Zhou, Nan
    Xu, Xiaolin
    Wei, Wenbin
    [J]. BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [4] Correlation of optic disc morphometry and optic disc microvasculature assessed with optical coherence tomography angiography
    Falavarjani, Khalil Ghasemi
    Shenazandi, Hamideh
    Naseri, Dariush
    Anvari, Pasha
    Sedaghat, Ahad
    Hashemi, Masih
    Sadun, Alfredo A.
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (06): : 595 - 599
  • [5] Optical coherence tomography angiography for the measurement of optic disc: Macular relationship
    Serafino, Massimiliano
    Scaramuzzi, Matteo
    Bonsignore, Francesco
    Vitale, Lucia
    Magli, Adriano
    Nucci, Paolo
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (02) : 543 - 547
  • [6] Optical coherence tomography angiography at the acute phase of optic disc edema
    Rougier, Marie-Benedicte
    Le Goff, Melanie
    Korobelnik, Jean-Francois
    [J]. EYE AND VISION, 2018, 5
  • [7] Optical coherence tomography angiography at the acute phase of optic disc edema
    Marie-Bénédicte Rougier
    Mélanie Le Goff
    Jean-François Korobelnik
    [J]. Eye and Vision, 5
  • [8] Swept source optical coherence tomography angiography in optic disc melanocytoma
    Jain, Astha
    Thirumalesh
    Shetty, Bhujang K.
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (06): : E239 - E241
  • [9] Morphologic Features of Buried Optic Disc Drusen on En Face Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Kim, Min Seok
    Lee, Kyoung Min
    Hwang, Jeong-Min
    Yang, Hee Kyung
    Woo, Se Joon
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 213 : 125 - 133
  • [10] Optical coherence tomography angiography findings of an optic disc melanocytoma in a glaucoma eye
    Yoshiyuki Kita
    Gábor Hollό
    Akiko Murai
    Ritsuko Kita
    Akito Hirakata
    [J]. International Ophthalmology, 2019, 39 : 677 - 682