Passive neutron area monitor with pairs of TLDs as neutron detector

被引:18
|
作者
Rene Vega-Carrillo, Hector [1 ]
Arlete Guzman-Garcia, Karen [2 ]
Gallego, Eduardo [2 ]
Lorente, Alfredo [2 ]
机构
[1] Univ Autonoma Zacatecas, Unidad Acad Estudios Nucl, Zacatecas 98068, Zac, Mexico
[2] Univ Politecn Madrid, Dept Ingn Nucl, E-28006 Madrid, Spain
关键词
Neutron; Ambient dose equivalent; Neutron area monitor; Passive; TLD600; TLD700; BONNER SPHERE SPECTROMETER; RESPONSE MATRIX; SPECTRA; FIELD;
D O I
10.1016/j.radmeas.2014.08.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A passive neutron area monitor has been designed using Monte Carlo methods; the monitor is a polyethylene cylinder with pairs of thermoluminescent dosimeters (TLD600 and TLD700) as thermal neutron detector. The monitor was calibrated with a bare and a thermalzed (AmBe)-Am-241 neutron sources and its performance was evaluated measuring the ambient dose equivalent due to photoneutrons produced by a 15 MV linear accelerator for radiotherapy and the neutrons in the output of a TRIGA Mark III radial beam port. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:30 / 34
页数:5
相关论文
共 50 条
  • [21] PASSIVE NEUTRON SPECTROMETER USING A NUCLEAR TRACK DETECTOR
    FRANK, AL
    BENTON, EV
    ALBERGOTTI, JC
    NUCLEAR INSTRUMENTS & METHODS, 1974, 122 (03): : 433 - 441
  • [22] Adjustment of neutron multiplicities in a neutron monitor
    V. K. Korotkov
    Geomagnetism and Aeronomy, 2012, 52 : 103 - 110
  • [23] Preliminary studies for a high energy neutron area monitor
    Devine, RT
    Hsu, HH
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 99 - 100
  • [24] Adjustment of Neutron Multiplicities in a Neutron Monitor
    Korotkov, V. K.
    GEOMAGNETISM AND AERONOMY, 2012, 52 (01) : 103 - 110
  • [25] PASSIVE GAMMA, NEUTRON MONITOR FOR FISSILE MATERIAL IN SCRAP AND WASTE
    GORIS, P
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 16 (JUN): : 151 - 152
  • [26] AREA RADIATION MONITOR AT THE INTENSE PULSED NEUTRON SOURCE
    EICHHOLZ, JJ
    LYNCH, FJ
    MUNDIS, RL
    HOWE, ML
    DOLECEK, EH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 804 - 807
  • [27] Conceptual design of a new multi-purpose, passive and flexible neutron area monitor with two configurations
    Garcia-Baonza, Roberto
    Lorente, Alfredo
    Ibanez, Sviatoslav
    Gallego, Eduardo
    Garcia-Fernandez, Gonzalo F.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [28] Efficiency calibration of a large-area neutron detector by using Am/Be neutron source
    Hu, QY
    Ye, YL
    Li, ZH
    Li, XQ
    Jiang, DX
    Zheng, T
    Wang, QJ
    Hua, H
    Wu, CE
    Chen, ZQ
    Ying, J
    Pang, DY
    Zhang, GL
    Wang, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 473 - 477
  • [29] Feasibility of a large area detector for fast neutron imaging
    Bogolubov, E.
    Koshelev, A.
    Mikerov, V.
    Sviridov, A.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [30] A LARGE AREA POSITION-SENSITIVE NEUTRON DETECTOR
    BERLINER, R
    MILDNER, DFR
    PRINGLE, OA
    KING, JS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 481 - 495